FUJI错误代码查询.pdf - 第619页
the board holder has not been detached, or when the board holder size is inappropriate. Remedy: Detach the board holder. ------------------------------ Code: 12063031 Display: 侧夹紧错误 Used by: GPX,NXTP Cause: 侧夹紧落空 Remedy:…
also occur if the cleaner notch is out even though the cleaner was not at the escape position.
Remedy: In the former instance, use [HEAD ATTACHMENT] on command page 553-2(4) to properly
connect the cleaner to the drive axis. If necessary, make sure that the lower cleaner connection check
sensor and the cleaner connection position proximity check sensor (X05D:LW CLR CPL CHK and
X03E:CLNR NEAR CHK) are functioning normally. In the latter case, manually return the cleaner to the
origin position.
------------------------------
Code: 1206302B
Display: "Cleaner Sandwich Position Out of Range"
Used by: GP6
Cause: This error occurs if an attempt is made to close the cleaner head while the cleaner is at an
inappropriate position. The cleaner is either at the origin or outside the cleaning range.
Remedy: Move the cleaner inside the cleaning range. On a double-side cleaner, the cleaning range is
between the positions set by the following Proper data parameters: "222:Max Limit Position S clnr"and
"223:Min Limit Position S clnr." On a single-side cleaner, it is between the positions set by the following
Proper data parameters: "232:Max Limit Position Y clnr" and "233:Min Limit PositionY clnr."
------------------------------
Code: 1206302C
Display: "Cleaner Notch Action Error"
Used by: GP6
Cause: Removal of the cleaner notch required longer than the specified time. This error may also occur if
the cleaner notch is in even though the cleaner is not proximate to the cleaner drive axis (the Y-axis for a
double-side cleaner, or the S-axis for a single-side cleaner).
Remedy: Use I/O commands to check the sensor. If necessary, return the cleaner to the proper status.
------------------------------
Code: 1206302D
Display: "Cleaner XY catch"
Used by: GP6
Cause: Removal of the notch connecting the single-side cleaner to the XY-axis required longer than the
specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 1206302E
Display: "Move SQG Start Position at Printing"
Used by: GP551,GP6
Cause: This error occurs if automatic operation is started with the double squeegee positioned inside the
printing area.
Remedy: Move the squeegee outside the printing area, either to the front or rear side.
------------------------------
Code: 1206302F
Display: 请除去印刷状态不明的电路板
[Printing Not Possible. Remove Board]
Used by: GPX,NXTP
Cause: 判断出主搬运轨道的电路板正处在印刷途中。印刷途中的电路板不能够印刷。
Remedy: 请除去主搬运轨道的电路板,修正后,从IN搬运轨道处载入。
<img src="$LKEY_ERRIMG_MC$/1206302F.PNG">
------------------------------
Code: 12063030
Display: "Univ holder at inner limit"
Used by: GP551,GP6
Cause: Board holder interference occurred while changing the conveyor width. This error occurs when
第 618 页
the board holder has not been detached, or when the board holder size is inappropriate.
Remedy: Detach the board holder.
------------------------------
Code: 12063031
Display: 侧夹紧错误
Used by: GPX,NXTP
Cause: 侧夹紧落空
Remedy: 请从主搬运轨道处除去落空的电路板。
<img src="$LKEY_ERRIMG_MC$/12063031.PNG">
------------------------------
Code: 12063032
Display: 电路板厚度异常
Used by: GPX,NXTP
Cause: 检测到边缘夹紧顶起。电路板厚度可能有异常。
Remedy: 1.请确认电路板厚度。
2.请查看用于确认电路板厚度的传感器(※1)。(请联系售后服务人员)
※1 NXTP:RX008、RX009
GPX :RX000
<img src="$LKEY_ERRIMG_MC$/12063032.PNG">
------------------------------
Code: 12063033
Display: 定位点尺寸测量错误 电路板
Used by: GPX,NXTP
Cause: 电路板的定位点尺寸测量失败。
Remedy: 1.请确认定位点是否脏。
2.请确认定位点形状及检索范围是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12063033.PNG">
------------------------------
Code: 12063034
Display: 定位点尺寸测量错误 钢板
Used by: GPX,NXTP
Cause: 钢板的定位点尺寸测量失败。
Remedy: 1.请确认定位点是否脏。
2.请确认定位点形状及检索范围是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12063034.PNG">
------------------------------
Code: 12063035
Display: 补正计算异常
基准定位点同一位置
Used by: GPX,NXTP
Cause: 基准定位点的位置被指定成了同一位置。
同一位置时,不能够进行角度补正。
Remedy: 定位点的位置请尽量指定有一定距离的不同的2点。
<img src="$LKEY_ERRIMG_MC$/12063035.PNG">
------------------------------
Code: 12063036
Display: 电路板落下了
Used by: GPX
Cause: 通过相机机械手检查了主搬运轨道的电路板有无,但是电路板到达传感器却无法测出。
Remedy: 可考虑在双印刷的夹紧中电路板落下了。请确认是否有落下的电路板。有可考虑在没有放入电路板的情况下
按下了启动SW的情况。
第 619 页
如果不打开前门进行有无电路板的确认,就不能解除错误。
<img src="$LKEY_ERRIMG_MC$/EI0002.bmp">
------------------------------
Code: 12063037
Display: 定位点测试错误 电路板
Used by: GPX,NXTP
Cause: 虽然改变着电路板定位点读取条件(光源、快门速度)进行读取测试,但是无法读取定位点。
Remedy: 定位点尺寸、颜色出错。
也有可能定位点加工不良。
<img src="$LKEY_ERRIMG_MC$/12063037.PNG">
------------------------------
Code: 12063038
Display: 定位点测试错误 钢板
Used by: GPX,NXTP
Cause: 虽然改变着电路板定位点读取条件(光源、快门速度)进行读取测试,但是无法读取定位点。
Remedy: 定位点尺寸、颜色出错。
也有可能定位点加工不良。
<img src="$LKEY_ERRIMG_MC$/12063038.PNG">
------------------------------
Code: 12063039
Display: 类型识别 定位点间距异常 电路板
Used by: GPX,NXTP
Cause: 在电路板定位点的读取测试中,测出了定位点间距与设定值不同的定位点。
Remedy: 有可能误识别了电路板定位点。请执行以下其中一个对策。
1.将检索范围(扫描区域)变窄。
2.使用别的定位点。
<img src="$LKEY_ERRIMG_MC$/12063039.PNG">
------------------------------
Code: 1206303A
Display: 类型识别 定位点间距异常 钢板
Used by: GPX,NXTP
Cause: 在钢板定位点的读取测试中,测出了定位点间距与设定值不同的定位点。
Remedy: 有可能误识别了钢板定位点。请执行以下其中一个对策。
1.将检索范围(扫描区域)变窄。
2.使用别的定位点。
<img src="$LKEY_ERRIMG_MC$/1206303A.PNG">
------------------------------
Code: 1206303B
Display: 定位点误测出 电路板
Used by: GPX,NXTP
Cause: 在电路板定位点读取测试中,在与本来应有的位置(绿色的○)所不同的位置(红色的×)上测出了定位点
。
Remedy: 有可能误识别了电路板定位点。请执行以下其中一个对策。
1.将检索范围(扫描区域)变窄。
2.使用别的定位点。
<img src="$LKEY_ERRIMG_MC$/1206303B.PNG">
------------------------------
Code: 1206303C
Display: 定位点误测出 钢板
Used by: GPX,NXTP
Cause: 在钢板定位点读取测试中,在与本来应有的位置(绿色的○)所不同的位置(红色的×)上测出了定位点。
第 620 页