accuracy of the device description, or reduce the pickup uncertainty so that blob analysis is no longer required. ------------------------------ Code: 1C410134 Display: Used by: Cause: There is insufficient data in the g…
Remedy: Make the device description tolerance settings (pickup tolerance x, pickup tolerance y, rotation
tolerance) smaller. Generally, if the parts are small, the edge of the nozzle protrudes, and this makes the
vacuum weaker, and the parts can therefore easily slide after vision processing is complete. Caution must
be exercised on this point.
------------------------------
Code: 1C410129
Display:
Used by:
Cause: Training cannot be done because the coarse edge is incorrect.
Remedy: Enter a correct device description coarse edge. Check the following:
Coarse_edge_angle
Coarse_edge_l1
Coarse_edge_d1
Coarse_edge_l2
Coarse_edge_d2
Coarse_edge_e1_polarity
Coarse_edge_e3_polarity
break_rate
max_break
------------------------------
Code: 1C410130
Display:
Used by:
Cause: The coarse edge pickup tolerance is too large.
Remedy: Make the device description tolerance settings (pickup tolerance x, pickup tolerance y, rotation
tolerance) smaller.
------------------------------
Code: 1C410131
Display:
Used by:
Cause: The coarse edge tolerance (positional uncertainty) is too large.
Remedy: Make the generic device description tolerance settings (pickup tolerance x, pickup tolerance y,
rotation tolerance) smaller.
------------------------------
Code: 1C410132
Display:
Used by:
Cause: The blob cannot be found in the nozzle position.
Remedy: If the nozzle seen at the monitor is not dirty, this is probably a hardware problem.
------------------------------
Code: 1C410133
Display:
Used by:
Cause: A blob analysis failed to determine the device rotation angle during inspection. However, device
training indicated that the angle could be determined. Therefore the run-time image is not what the
software expects based on the device description. Pickup uncertainty is large enough to require that blob
analysis be used during device inspection. In such cases, during device training, the system uses the
device description to predict whether useful angle information will appear in the blob results. If the
system expects angle information to appear and it does not, then this error occurs.
Remedy: Check that the direction is correct. Also, check the part placement direction in PD. If the nozzle
edge protrudes from the part (the nozzle is too large) this error can also occur. Either improve the
第 1182 页
accuracy of the device description, or reduce the pickup uncertainty so that blob analysis is no longer
required.
------------------------------
Code: 1C410134
Display:
Used by:
Cause: There is insufficient data in the generic device description.
Remedy: Fix the generic device description. If this error occurs often, contact Fuji.
------------------------------
Code: 1C410139
Display:
Used by:
Cause: The nozzle edge is protruding from the part.
Remedy: Make the nozzle size smaller. If this error occurs often, contact Fuji.
------------------------------
Code: 1C410142
Display:
Used by:
Cause: The vision processing program angular uncertainty calculations are contradictory.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C410143
Display:
Used by:
Cause: The caliper window does not fit properly.
Remedy: Optically reduce the image magnification, correct the pickup nozzle, or center the nozzle in the
field of view. That is, make the generic device description tolerance settings (pickup tolerance x, pickup
tolerance y, rotation tolerance) smaller.
------------------------------
Code: 1C410144
Display:
Used by:
Cause: The input nozzle size value is not the same as the actual value.
Remedy: Input the correct value in the production program and retransmit the program.
------------------------------
Code: 1C420002
Display:
Used by:
Cause: The command to the vision processing system is abnormal.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420004
Display:
Used by:
Cause: A command made to vision processing is incorrect.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420007
Display:
Used by:
Cause: A command made to vision processing is incorrect.
第 1183 页
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420009
Display:
Used by:
Cause: A command made to vision processing is incorrect.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420010
Display:
Used by:
Cause: A command made to vision processing is incorrect.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420011
Display: 1C420011
Used by:
Cause: Even though the generic device descriptions were not transmitted correctly, production is carried
out. This error occurs when the machine finds Part data with the same name but a different date.
Remedy: Modify the Part data and then completely erase the production program, and retransmit it to the
machine. If this error occurs due to a fiducial mark, after initializing the system measure the Proper data
and then switch off and re-start the machine.
------------------------------
Code: 1C420012
Display:
Used by:
Cause: A command made to vision processing is incorrect.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420013
Display:
Used by:
Cause: A mark or part cannot be detected. If a mark is not detected, the mark size is incorrect, the mark
is dirty or the bright setting is incorrect.
Remedy: This generally occurs due to parts being mis-picked. Check that the mark size is correct and
that the mark is clean. Check and adjust the brightness setting by pressing the [VISION], [BRIGHT] and
[MARK] command keys. Generally, if the mark can be seen clearly at the monitor, adjustment is not
necessary.
------------------------------
Code: 1C420014
Display:
Used by:
Cause: Vision processing system communication error.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C420015
Display:
Used by:
Cause: An error occurred during file forwarding.
Remedy: Part of the system program or the data has been corrupted. Contact Fuji.
------------------------------