FUJI错误代码查询.pdf - 第600页

Display: ST1:Nozzle up/down error ST1:UP-lmt sensor ON Used by: CP643 Cause: The ST1 cylinder upper limit sensor is ON even though the machine has lowered the nozzle at ST1 to pick up a part. Remedy: Check the ST1 cylind…

100%1 / 5282
Used by: CP5,CP6M,CP65,CP652C,CP642,CP643
Cause: The quantity of cooling oil is not sufficient. There is a fault in the circulating motor. There is a
fault in the detecting sensor.
Remedy: Switch off the machine power and check if the oil quantity is within specifications. Check the
circulating motor and the detecting sensor.
------------------------------
Code: 12061012
Display: Nzl origin search err stn12.(cp6)
Used by:
Cause: The nozzle origin position cannot be found.
Remedy: If this error occurs often and at random (ie: not always in the same nozzle), check the
adjustment of the origin position sensor. If this error occurs in a specific nozzle, check the clutch section
of this nozzle.
------------------------------
Code: 12061013
Display: Pallet ID Zero Error
Used by: CP652C
Cause: The result of reading the pallet ID of the pallet on the up-elevator was a pallet ID of "0".
Remedy: Use the pallet ID write command to set a proper ID_No. A value from 1 to 255 can be used as a
valid ID_No. Refer to the Operation Manual for information regarding the ID_No write command.
------------------------------
Code: 12061014
Display: "Ref. side clamp mesh error" (CP-642)
Used by: CP642,CP643
Cause: The guiderail on the XY table did not mesh with the guide on the conveyor.
Remedy: Align the XY table guiderail with the guide on the conveyor.
------------------------------
Code: 12061015
Display: "Interfered with backup pin"
Used by: CP642,CP643
Cause: The XY table structure interfered with the backup pin.
Remedy: Change the position of the backup pin.
------------------------------
Code: 12061016
Display: "ST15 nozzle origin error.", "Return nzl hldr to org pos." (CP6/6M)
Used by: CP6,CP6M,CP65,CP642,CP643
Cause: A Station 15 nozzle origin position check failed to confirm the origin.
Remedy: Return the nozzle holder to a position near the origin. (Nozzle disorientation may occur after
continuous production involving 90[deg] rotation.) If this error occurs even though the nozzleholder is at
the origin position, the Station 15 origin position check sensor requires adjustment.
------------------------------
Code: 12061017
Display: ST1:Nozzle up/down error
ST1:UP-lmt sensor OFF
Used by: CP643
Cause: The ST1 cylinder upper limit sensor was OFF even though the stopper has been engaged to
prevent the nozzle at ST1 from descending,after the head at ST20 was a skipped head during D-axis
positioning or D-axis retraction at the start of automatic operation.
Remedy: Check the ST1 stopper and the ST1 cylinder upper limit sensor(X06A)
------------------------------
Code: 12061018
第 599 页
Display: ST1:Nozzle up/down error
ST1:UP-lmt sensor ON
Used by: CP643
Cause: The ST1 cylinder upper limit sensor is ON even though the machine has lowered the nozzle at
ST1 to pick up a part.
Remedy: Check the ST1 cylinder upper limit sensor(X06A)
------------------------------
Code: 12061019
Display: ST11:Nozzle up/down error
ST11:UP-lmt sensor OFF
Used by: CP643
Cause: The ST11 cylinder upper limit sensor was OFF even though the stopper has been engaged to
prevent the nozzle at ST11 from descending,after the head at ST10 was a skipped head during at the start
of automatic operation.
Remedy: Check the ST11 stopper and the ST11 cylinder upper limit sensor(X06B)
------------------------------
Code: 1206101A
Display: ST11:Nozzle up/down error
ST11:UP/DWN sensor error
Used by: CP643
Cause: Both the cylinder upper limit and lower limit sensors are ON even though the machine has
lowered the nozzle ae ST11 to place a part.
Remedy: Check the ST11 cylinder upper limit sensor(X06B)
------------------------------
Code: 1206101B
Display: Production method does not match
Check Proper and header data
Used by: CP643
Cause: The production program item "Multiple pcb set" is set to "2", even though the Proper data item
"mc_pcb_type" is set to "1". These data do not match.
Remedy: Use one of the following remedies.
1. Set Proper item "mc_pcb_type" to "0".
2. Set the production program item "Multiple pcb set" to "1" and ensure there is only one board's worth of
sequences in the sequence data.
------------------------------
Code: 1206101C
Display: Nozzle holder origin position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The nozzle holder is not at its origin position.
Remedy: Frequent occurrences of this error at the same shaft indicates a shaft rotation problem.
------------------------------
Code: 1206101D
Display: Parts height sensor malfunction.
Used by: CP-742ME, CP-742E, CP-752E
Cause: Parts height sensor is soiled.
Remedy: Wipe the sensor beam emitter and receptor lenses with a soft object such as a cotton swab, etc.
------------------------------
Code: 1206101E
Display: Parts height sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: Parts height sensor processing was not completed in the prescribed period of time.
第 600 页
Remedy: If this error occurs frequently, there may be a parts height sensor failure.
------------------------------
Code: 1206101F
Display: Feeder feed retract limit error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: Feeder feed retract limit error.
Remedy: Check to see if the feeder feed lever is at the retract limit position. If not, perform an I/O check
to retract the feed lever. If the retract limit sensor fails to switch on even though the feed lever is
retracted, adjust the sensor and dog positions. If the error persists even after the adjustments, there may
be a sensor wiring problem or a sensor failure.
------------------------------
Code: 12061020
Display: The X-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The X-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Remedy: Verify that the X-axis coordinates are correct in the production program.
------------------------------
Code: 12061021
Display: The X-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The X-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Remedy: Verify that the X-axis coordinates are correct in the production program.
------------------------------
Code: 12061022
Display: The Y-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The Y-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Remedy: Verify that the Y-axis coordinates are correct in the production program.
------------------------------
Code: 12061023
Display: The Y-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The Y-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Remedy: Verify that the Y-axis coordinates are correct in the production program.
------------------------------
Code: 12061024
Display: The Z-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The Z-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Remedy: Verify that the parts height is set correctly in Part data.
------------------------------
Code: 12061025
Display: The Z-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The Z-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Remedy: Verify that the parts height is set correctly in Part data.
------------------------------
Code: 12061026
Display: The D1-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The D1-axis target position exceeds the plus-limit of the travel range specified in Proper data.
第 601 页