FUJI错误代码查询.pdf - 第1384页
------------------------------ Code: 1D0E0021 Display: Used by: Cause: The corner lead cannot be found. Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used. --------------…
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0016
Display:
Used by:
Cause: The lead length was too short (less than 90% of the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0017
Display:
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0018
Display:
Used by:
Cause: The lead length was too short (less than 90% of the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0019
Display:
Used by:
Cause: The lead length was too long (over 10% longer than the setting in Part data (PDG)).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E001A
Display:
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E001B
Display:
Used by:
Cause: There are too many leads (set in PDG).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E001C
Display:
Used by:
Cause: There are too many leads (set in PDG).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0020
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
第 1383 页
------------------------------
Code: 1D0E0021
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0022
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0023
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0024
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0025
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0026
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0027
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E0041
Display:
Used by:
Cause: The lead cannot be found. The pitch was too wide or there were not enough leads.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0E0060
第 1384 页
Display:
Used by:
Cause: The corner lead is bent.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D0E3400
Display:
Used by:
Cause: The part is too short in the X direction.
Remedy: Check the part size, and check the image taken by vision processing.
------------------------------
Code: 1D0E4400
Display:
Used by:
Cause: The part is too long in the X direction.
Remedy: Check the part size, and check the image taken by vision processing.
------------------------------
Code: 1D0E8002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D0E8100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D0E8110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D0E8111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D0E8112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D0E8113
Display:
第 1385 页