Code: 120661??
Display: Bad nozzle detected:PM??-?
Used by: QP132
Cause: The number of vision processing errors has exceeded the specified figure, and the nozzle is
therefore judged to be defective.
The question marks in the code represent the module number and the nozzle number in that order. The
first two question marks in the display represent the module number, and the question mark after the
hyphen represents the nozzle number.
Remedy: Check the status of the nozzles.
------------------------------
Code: 12066800
Display: DATA LOGIC ERROR [12066800]
Used by: QP132
Cause: There is no data table for setting the fiducial mark that has been read. Or The Pallet ID issued
during advanced pick-up is incorrect. On the QP132, the board information is saved in the table when the
board is loaded, and Data is written to each pallet ID at the Approach Station. As a result, when a board
exists in the pallet loader after being set using the I/O operation, the board information will be deleted if
the reset-start operation is carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066801
Display: DATA LOGIC ERROR [12066801]
Used by: QP132
Cause: There is no program to be executed at the mark read station.
Remedy: Transmit the necessary program.
------------------------------
Code: 12066802
Display: DATA LOGIC ERROR [12066802]
Used by: QP132
Cause: When the pallet size corresponding to the stored ID was read, data different than the pallet size
being used in production was detected.
Remedy: Check the pallet size in the machine. Has the wrong size pallet been inserted? If a pallet change
has been carried out the pallet initialization operation may not in fact be necessary, nevertheless this
initialization operation should always be carried out when a new pallet is used. Also note that the
possibility exists that the pallet initialization operation is not properly completedevery time. In such a case
execute the [PLT CHANGE] command, unload the pallets, and then execute the [INITI TION] command.
------------------------------
Code: 12066803
Display: DATA LOGIC ERROR [12066803]
Used by: QP132
Cause: The pitch was not continuous when the five individual IDs attached to the pallet were read at the
approach station.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
第 651 页
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066804
Display: DATA LOGIC ERROR [12066804]
Used by: QP132
Cause: A data table for managing the pallet is created at the approach station however, there was no
empty table available and thus this data table could not be created. This is an ID read mistake due to
damage to the pallet ID reader. Or there is a bug in the QP132 software.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066805
Display: DATA LOGIC ERROR [12066805]
Used by: QP132
Cause: The ID number did not conform when the five individual IDs attached to the pallet were read at
the approach station. Or Inconsistences also exist.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command.
Once the SS-axis has been returned to its origin position using the [SS Move] command, ensure that the
error has been cleared. It will not be possible to proceed with operation unless the error is cleared. This
[ID Number] can only be written when the pallets are loaded. When replacing a damaged pallet, remove
the ID plate from the previous pallet and attach it to the new one. In addition, there is also the possibility
that previous pallet loading was not completed successfully on the previous board. In this situation,
perform the [Load Pallet] command once all pallets have been unloaded.
------------------------------
Code: 12066806
Display: DATA LOGIC ERROR [12066806]
Used by: QP132
Cause: There was no stored board information when the ID was written at the approach station. On the
QP132, the board information is saved in the table when the board is loaded, and the pallet ID is saved at
the mark read station after the board is loaded. As a result, when a board exists in the pallet loader after
being set using the I/O operation, the board information will be deleted if the reset-start operation is
carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066807
Display: DATA LOGIC ERROR [12066807]
Used by: QP132
Cause: A contradiction was detected such as the pallet length being exceeded, when the ID write
第 652 页
information was being determined from the number and sizes of boards in the pallet.
Remedy: Given this status, production cannot be interrupted when there is a pallet at the pallet setup
station (mark read station). After unloading all boards inside the machine using the flush out operation,
then restart normal operation.
------------------------------
Code: 12066808
Display: DATA LOGIC ERROR [12066808]
Used by: QP132
Cause: (Reserved)
Remedy:
------------------------------
Code: 12066809
Display: DATA LOGIC ERROR [12066809]
Used by: QP132
Cause: No database can be found for the pallet number reported by the PMC or the Approach Station.
This error will occur when production is recommenced when the flush out process is not fully complete, or
when a damaged part is replaced without first replacing the ID plate.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. Refer to the pallet ID list displayed using the [Pallet Skip]
command to confirm whether any pallets are using an identical ID. When replacing a damaged pallet,
remove the ID plate from the previous pallet and attach it to the new one.
It will not be possible to proceed with operation unless the error is cleared. If necessary restart normal
operation after unloading all boards inside the machine using the [Flush Out] command.
------------------------------
Code: 1206680A
Display: DATA LOGIC ERROR [1206680A]
Used by: QP132
Cause: The status issued from the PMC during automatic operation was "0". Automatic production on
the QP1 determines the production part according to the status report issued from the PMC. This error
should not occur according to logic and is being investigated as a reliability issue.
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause. If this problem occurs regularly,
output trace data from the machine and send it to Fuji for analysis.
------------------------------
Code: 1206680B
Display: DATA LOGIC ERROR [1206680B]
Used by: QP132
Cause: After automatic production is restarted, the program name stored for the pallet ID at the
approach station is different from the program name prior to restart.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206680C
Display: DATA LOGIC ERROR [1206680C]
第 653 页