FUJI错误代码查询.pdf - 第80页
Display: Same as code Used by: GP551,GP6 Cause: There is a logical error in a cleaning sequence. The value replacing the "?" in the code is the number of the problematic cleaning sequence, when the number of th…
Used by: GPX-C
Cause: 印刷位置的设置允许范围会受其它参数(丝网尺寸、锡膏卷直径)的影响而变动。如果其他参数值太大,则
印刷范围就无法合理设置。
Remedy: 请调小Mesh Size或Roll Width。
------------------------------
Code: 1101C50?
Display: 1101C50?
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: ? represents a Z sequence number, where the first Z sequence is "1". The specified X (Z) value
exceeds the range.
Remedy: The input range for X (Z) is from -1 to -500 (-0.01mm to -5.00mm). Correct and then retransmit
the data.
------------------------------
Code: 1101C51?
Display: 1101C51?
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: ? represents a Z sequence number, where the first Z sequence is "1". The specified Y (SPEED)
value exceeds the range.
Remedy: The input range for Y (SPEED) is from 0 to 8,000 (0.00mm/sec to 80.00mm/sec). Correct and
then retransmit the data.
------------------------------
Code: 1101C52?
Display: 1101C52?
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: ? represents a Z sequence number, where the first Z sequence is "1". The X (Z) value is logically
wrong.
Remedy: Ensure that data values become smaller in sequential order.
------------------------------
Code: 1101C53?
Display: Same as code
Used by: GP551,GP6
Cause: The movement range for a cleaning sequence has been exceeded. The value replacing the "?" in
the code is the number of the problematic cleaning sequence, when the number of the first
cleaningsequence is 1.
Remedy: Check the Proper data and production program data values. The cleaning sequence range for a
double-side cleaner is found by subtracting "org_pos_clnr" (the cleaner's program origin) from both
"max_limit_pos_s_clnr" and "min_limit_pos_s_clnr", and converting the results to units of 1/100 mm. The
cleaning sequence range for a single-side cleaner is found by subtracting "org_pos_clnr" (thecleaner's
program origin) from both "max_limit_pos_y_clnr" and "min_limit_pos_y_clnr", and converting the res lts to
units of 1/100 mm.
------------------------------
Code: 1101C54?
Display: Same as code
Used by: GP551,GP6
Cause: The speed range for a cleaning sequence has been exceeded. The value replacing the "?" in the
code is the number of the problematic cleaning sequence, when the number of the first cleaning sequence
is 1.
Remedy: Correct the data and retransmit the program. The speed range for cleaning sequences is from 1
to 14500 [1/100 mm/second]. The -1 indicating the final cleaning sequence is not checked.
------------------------------
Code: 1101C55?
第 79 页
Display: Same as code
Used by: GP551,GP6
Cause: There is a logical error in a cleaning sequence. The value replacing the "?" in the code is the
number of the problematic cleaning sequence, when the number of the first cleaning sequence is 1.
Remedy: Make sure that the number of the specified cleaning sequence is decreasing in sequence number
order.
------------------------------
Code: 1101C56?
Display: Same as code.
Used by: GP6
Cause: The "?" represents the printing sequence number when the first printing sequence is 1. This is a
printing sequence logic error.
Remedy: Check that the set printing sequence is not gradually decreasing in value.
------------------------------
Code: 1101C6??
Display: same as code (1101C600 + (I-1) / 20,where I is the sequence number).
Used by: CP643
Cause: The second board has a block number that is lower than the first board
maximum block number.
Remedy: Check the block numbers in the sequences indicated by the error message,as well as the first
board's maximum block number.
------------------------------
Code: 1101C700
Display: 同一个供料平台No./料站No.所设定的顺序数据中、同时存在0 和1 的供料器跳过设定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 因为在同一供料平台No./料站No.所设定的顺序数据中,同时存在设定供料器跳过和未设定为供料器跳过
,所以不能正常运转。
Remedy: 请将同一供料平台No./料站No.所设定的顺序数据的供料器跳过全部修正为相同的设定。
------------------------------
Code: 1101C701
Display: 不是joint模式时、不能在顺序数据中进行供料平台2的设定。
Used by: XP141,XP142
Cause: 不是joint模式时、不能在顺序数据中进行供料平台2的设定。
Remedy: 请将供料平台No.设定为2的顺序数据全部跳过或删除。
------------------------------
Code: 1101C702
Display: 没有种类为 'D' 的顺序数据。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 顺序数据中没有贴装顺序(种类为‘D’)。
Remedy: [机上编辑] 在没有贴装顺序进行运转时,请将电路板数据的通过模式设定为「1:Pass」。
[Fuji Flexa] 在没有贴装顺序进行运转时,请将Pass Mode设定为「On」或者は「Auto」。
------------------------------
Code: 1101C703
Display: X坐标超过电路板的范围。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
Cause: 显示出顺序数据的X坐标在电路板尺寸以外。
Remedy: 请将X坐标设定在电路板尺寸以内。
------------------------------
Code: 1101C704
Display: Y坐标超过电路板的范围。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
第 80 页
Cause: 显示出顺序数据的Y坐标在电路板尺寸以外。
Remedy: 请将Y坐标设定在电路板尺寸以内。
------------------------------
Code: 1101C705
Display: 同一个子电路板内存在具有相同的定位点No.的顺序。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 存在着在同一个子电路板内设定有相同定位点No.的基准定位点引脚顺序。
Remedy: 请更变任意一侧的顺序数据的子电路板No.或定位点No.的设定。
------------------------------
Code: 1101C706
Display: 主定位点No.和子定位点No.相同。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: [机上编辑] 元件贴装顺序的主定位点No.和子定位点No.设定为相同的数值。
[Fuji Flexa] 元件贴装顺序的主定位点和子定位点设定为相同的数值。
Remedy: [机上编辑] 请输入主定位点No.和子定位点No.不同的数值。
[Fuji Flexa] 请选择主定位点和子定位点不同的定位点。
------------------------------
Code: 1101C707
Display: 未找到具有在主定位点No.中设定的定位点No.的定位点顺序。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在文件贴装顺序的主定位点上设定的值带有定位点No.,但找不到基准定位点引脚顺序。
Remedy: 请将要在主定位点No.上设定的基准定位点引脚顺序设定在元件贴装顺序之前。
------------------------------
Code: 1101C708
Display: 未找到具有在子定位点No.中设定的定位点No.的定位点顺序。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在文件贴装顺序的子定位点上设定的值带有定位点No.,但找不到基准定位点引脚顺序。
Remedy: 请将要在子定位点No.上设定的基准定位点引脚顺序设定在元件贴装顺序之前。
------------------------------
Code: 1101C709
Display: 被指定的供料平台No./料站No.中没有设定元件数据。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在顺序数据中设定的供料平台No.和料站No.中没有设定数据。
Remedy: 在供料器安装上指定的供料平台No./料站No.中设定数据,或指定已设定的供料平台No./料站No.。
------------------------------
Code: 1101C70A
Display: 同一个电路板No.的顺序数据中、同时存在0 和1 的电路板跳过设定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在同一块子电路板No.的顺序数据中,同时存在着设定子电路板跳过和未设定子电路板跳过,所以不能正常运
转。
Remedy: 请将同一块子电路板No.的顺序数据中的子电路板跳过全部修正成相同的设定。
------------------------------
Code: 1101C70B
Display: 在同一块子电路板内的顺序中不存在PlaceBefore所指定的参考记号 (注解) 。
Used by: XP241,XP142,XP242
Cause: 在同一块子电路板No.的顺序中不存在PlaceBefore所指定的参考记号 (注解) 。
Remedy: 在PlaceBefore中,请先设定有必要执行的顺序的参考记号。
没有必要先执行时,请在PlaceBefore中不要进行任何设定。
设定的参考记号的顺序存在于不同的机器中时,请照样生产。
------------------------------
Code: 1101C70C
第 81 页