Code: 15040512 Display: In-shifter pallet positioning error. Used by: QP132 Cause: The pallet is not at the correct position or the pallet arrival sensor (X050 P. IN ARRV CK) is not functioning correctly. Remedy: Manuall…

100%1 / 5282
Used by:
Cause: This error is the result of the board clamp on the in-conveyor side being in the clamped status.
Remedy: Unclamp the board clamp on the in-conveyor side. Check the operation of the entry board
pusher clamp limit sensor.
------------------------------
Code: 1504050C
Display: IN INTERLOCK PCB PASSED ON
LD_ERR 1504050C
Used by:
Cause: The in-conveyor board popped up onto the loader.
Remedy: Set the board on the loader or return it to the in-conveyor. Check the operation of the in-
conveyor board pass-through-check sensor.
------------------------------
Code: 1504050D
Display: IN INTERLOCK HOOK PULLED OFF
LD_ERR 1504050D
Used by:
Cause: The PI-axis board hooks was not in the released status.
Remedy: Release the PI-axis board hooks. Check the operation of the PI-axis hook release status sensor.
------------------------------
Code: 1504050E
Display: IN INTERLOCK PLT ARRIVED2 OFF
LD_ERR 1504050E
Used by:
Cause: There was a pallet on the loader when the loader was retracting.
Remedy: Check the operation of the loading pallet-arrival-check 2 sensor.
------------------------------
Code: 1504050F
Display: IN INTERLOCK SS NOT ORG POS
LD_ERR 1504050F
Used by:
Cause: The SS-axis is not at its origin position.
Remedy: Move the SS-axis to its origin position.
------------------------------
Code: 15040510
Display: IN INTERLOCK PLT PUSH ON
Loader error: 15040510
Used by: QP132
Cause: When the pallet loader attempted to move to its extended position or, to its retracted position, the
pallet pusher was not at the retracted position.
Remedy: Check the operation of the return conveyor board pusher (X04B: RCV PUSH BWEND) using I/O
commands and adjust if necessary.
------------------------------
Code: 15040511
Display: X051 P_IN_PASS_CK Error
Used by: QP132
Cause: Either the sensor (X051 P_IN_PASS_CK) is defective, or a pallet is not unloader from the pallet
loader.
Remedy: Adjust the sensor (X051 P_IN_PASS_CK) . If a pallet is not unloader, move it to the appropriate
position.
------------------------------
第 1145 页
Code: 15040512
Display: In-shifter pallet positioning error.
Used by: QP132
Cause: The pallet is not at the correct position or the pallet arrival sensor (X050 P. IN ARRV CK) is not
functioning correctly.
Remedy: Manually move the pallet on the in-shifter to the left and confirm that it is detected by the pallet
arrival sensor. If the pallet is not detected, check the condition of the sensor.
------------------------------
Code: 15040600
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040601
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040602
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040603
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040604
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040605
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040606
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040607
第 1146 页
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040608
Display: )NOT FIT PCB DATA
Loader error: 15040608
Used by: QP132
Cause: The board unload position calculations could not be made.
Remedy: If there is a board remaining in the machine, then unload the board and restart.
------------------------------
Code: 15040609
Display: OUT INTERLOCK PLT PASSED1 ON
LD_ERR 15040609
Used by:
Cause: The production conveyor pallet popped up onto the unloader.
Remedy: Return the pallet to the production conveyor or slide the pallet onto the unloader. Check the
operation of the pallet unload pass-through-check 1 sensor.
------------------------------
Code: 1504060A
Display: OUT INTERLOCK PLT PASSED2 ON
LD_ERR 15040609
Used by:
Cause: The pallet on the return conveyor popped off the unloader.
Remedy: Slide the pallet onto the return conveyor or return the pallet to the unloader. Check the
operation of the pallet unload pass-through-check 2 sensor.
------------------------------
Code: 1504060B
Display: OUT INTERLOCK PCB CLAMP ON
LD_ERR 1504060B
Used by:
Cause: This error is the result of the board clamp on the out-conveyor side being in the clamped status.
Remedy: Unclamp the board clamp on the out-conveyor side. Check the operation of the exit board
pusher clamp limit sensor.
------------------------------
Code: 1504060C
Display: OUT INTERLOCK PCB PASSED ON
Loader error: 1504060C
Used by: QP132
Cause: The board on the out-conveyor popped off the unloader.
Remedy: Return the board to the unloader or slide it onto the out-conveyor. Check the operation of the
out-conveyor board pass-through-check sensor.
------------------------------
Code: 1504060D
Display: OUT INTERLOCK HOOK PULLED OFF
LD_ERR 1504060D
Used by:
Cause: The PO-axis board hooks was not in the released status.
Remedy: Release the PO-axis board hooks. Check the operation of the PO-axis hook release status
sensor.