------------------------------ Code: 12040505 Display: Part detected returning to feeder Used by: QP3 Cause: A part was detected returning to the feeder and vision processing was preformed but the part was not confirmed.…

100%1 / 5282
正常吸取的时候、请调查影像的明亮度是否有问题、元件的中央附近是否因为有污垢而没有摄入。
元件的中央附近比较暗的元件、有可能使功能产生错误动作。请将功能处于无效。
------------------------------
Code: 12040414
Display: 倾斜地将元件吸取了。
Used by: XP142,XP242
Cause: 倾斜地将元件吸取了。
Remedy: 请确认是否倾斜地将元件吸取了。
倾斜地吸取时,有可能使吸取状态变得恶劣。
请调查吸取高度、吸取位置、供料器的状态是否变得恶劣。
请进行吸嘴中心位置的重新测定。
正常地吸取时,对于形状歪斜的元件,功能有误动作的可能性。请使功能无效。
------------------------------
Code: 12040416
Display: Flux supply warning
Used by: QP3
Cause: The fixed flux unit is low on flux.
Remedy: Supply flux to the fixed flux unit.
------------------------------
Code: 12040417
Display: Tray pick-up position error
Used by: QP3
Cause: A part was found in the slot before the specified pick-up position.
Remedy: Reenter the pick-up position. If this error occurred even though a part does not exist,
a processing error may have occurred because the nozzle is bent.
Change the nozzle or disable this function.
------------------------------
Code: 12040418
Display: Tray pick-up position memory error
Used by: QP3
Cause: An attempt was made to return the part to the tray pick-up position, but the vacuum was OFF.
Remedy: The specified pick-up position has not been checked.
If the tray pick-up position is not clear, reset the pick-up position.
------------------------------
Code: 12040502
Display: Part placement confirmation error!
Used by: QP3
Cause: Failed to place the part.
Remedy: Check the nozzle and the action of the part placement confirmation sensor.
------------------------------
Code: 12040503
Display: Insertion error
Used by: QP3OF
Cause: Could not complete insertion of the positioning pins.
Remedy: Check that the positioning pins are not bent.
------------------------------
Code: 12040504
Display: Reserve
Used by: QP3
Cause: Reserve
Remedy: Reserve
第 473 页
------------------------------
Code: 12040505
Display: Part detected returning to feeder
Used by: QP3
Cause: A part was detected returning to the feeder and vision processing
was preformed but the part was not confirmed.
The pressure sensor may have output an incorrect signal.
If production is continued a placement may be duplicated.
Check the following before proceeding.
Remedy: Check if the sequence displayed in the parameters has been
placed on the panel.
If the part has been placed, an incorrect signal was received.
If this is the case, skip the sequence at the [Start] screen.
Furthermore, the sensor may be damaged, please contact your Fuji
representative.
If the part has not been placed, a vision processing error has
occurred due to a discharge or the part fell during movement.
Check the part has not fallen in the machine and that it is not
on the panel or camera. This may cause damage to the machine.
------------------------------
Code: 12040506
Display: Fix Flux Unit Error
Used by: QP3
Cause: Fix flux unit does not function correctly or the unit's status(set/not set) setting is incorrect.
Remedy: When the fix flux unit is mounted on the machine: Check that there
is no obstruction in an operating area of the unit.
When the fix flux unit is not mounted on the machine: Set the data (Fix Flux Sw) to "0" to set the
unit's status to "not set".
------------------------------
Code: 12040507
Display: Placement Revision Limit
Used by: NP133,NP134,NP153
Cause: The X-direction amount from the results of offset calculations preformed during placement
exceeds the value set for "Placement Revision X".
Remedy: Confirm that the specified value is not too small.
When contacting Fuji, ensure to attach trace data taken immediately after error occurred.
------------------------------
Code: 12040508
Display: Placement Revision Limit
Used by: NP133,NP134,NP153
Cause: The Y-direction amount from the results of offset calculations preformed during placement
exceeds the value set for "Placement Revision Y".
Remedy: Confirm that the specified value is not too small.
When contacting Fuji, ensure to attach trace data taken immediately after error occurred.
------------------------------
Code: 12040601
Display: Parts out limit (remaining parts).
Used by:
Cause: The number of parts remaining has reached the low quantity limit.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
第 474 页
Remedy: Resupply parts to the feeder at the target slot.
------------------------------
Code: 12040602
Display: Splicing warning (remaining parts).
Used by:
Cause: The number of parts remaining has reached the splicing low quantity limit.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
Remedy: Splice new parts to the feeder at the target slot.
------------------------------
Code: 12040603
Display: Parts out warning (remaining time).
Used by:
Cause: The number of parts remaining has reached the low quantity limit (time).
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or using the parts administration functions at the machine.
Remedy: Resupply parts to the feeder at the target slot, or prepare parts for resupply.
------------------------------
Code: 12040604
Display: Splicing limit.
Used by:
Cause: The number of parts remaining has reached the splicing limit.
This error is also a warning for faulty splicing.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
Remedy: Carry out verification again for the parts on the feeder at the target slot.
------------------------------
Code: 12040605
Display: Verification incomplete.
Used by:
Cause: The machine attempted to pick-up a part for which verification is not complete.
Verification has not been properly completed.
Communications with Fujitrax Verifier may be in progress.
The parameter indicates the target slot number.
Remedy: Carry out verification using the Handy Terminal.
If communications with Fujitrax Verifier are still in progress,
complete the communications at the device check screen,
and continue production when verification is complete.
------------------------------
Code: 12040606
Display: Device check incomplete
Used by:
Cause: Production cannot commence because the device check has not been completed.
Remedy: Perform verification for any incomplete devices using the device check panel.
------------------------------
Code: 12040632
Display: Duplicate FIDL
Used by:
Cause: An FIDL for a feeder that is already registered for another feeder on the machine has been
submitted.
An FIDL for a feeder loaded on the machine has been duplicated.