FUJI错误代码查询.pdf - 第1134页

Code: 15040410 Display: Out-carrier advance limit error. Used by: CP-732E, CP-742ME, CP-742E Cause: The out-carrier has deviated from the advance limit position. Remedy: Check the out-carrier position. If the out-carrier…

100%1 / 5282
3-2.搬运轨道搬入高度的再调整
4.电路板重(请与本公司的Support联系)
5.电路板薄导致被夹入在搬运轨道皮带和轨道之间(请与本公司的Support联系)
8.到达传感器的故障(请与本公司的Support联系)
9.通孔导致的电路板检测困难(请利用停止块偏移设置)
10.电路板的切口(请利用停止块偏移设置)
11.从主搬运轨道排出时,存在电路板粘在钢板上的可能性。请确认。
12.存在电路板送信号到达后工序之前已经OFF的情况。如果机器内有电路板时请除去。(GPX)
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040402.PNG">
------------------------------
Code: 15040403
Display: CHECK NEXT CONVEYOR
(QP132)NEXT PROCESS NOT COMP
Loader error: 15040403
Used by: CP3,GL2,GSP2,GSP3,IP1,IP2,QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: When the machine was SMEMA compatible, a board was unloaded from the out conveyor, but the
BUSY signal did not turn OFF within the time specified in Proper data's 321.L_send_chk.timer item.
Remedy: Check that the board is not stuck on the conveyor. Increase the time setting in
321.L_send_chk.timer. This change must be saved and transmitted to the machine before it can take
effect.
------------------------------
Code: 15040404
Display: (IP1)LD_ERR: 15040404
(QP132)OUT_CVR PCB NOT ARRV
Loader error: 15040404
Used by: IP1,QP132,NP132,NP133
Cause: The board has been unloaded from the main-conveyor but, the board-arrival sensor on the out-
conveyor has not detected the arrival of the board within the given time. When the SMEMA signals were
used, the board did not arrive at the next machine within the given 30 seconds after being unloaded from
the out-conveyor. The board request signal (PCB_REQ) remains on.
Remedy: Check that the board has not been caught up somewhere on the conveyor.
------------------------------
Code: 15040405
Display: (IP1)LD_ERR: 15040405
(QP132)PCB OUT NOT COMP
Loader error: 15040405
Used by: IP1,QP132,NP132,NP133
Cause: The board has been unloaded from the main-conveyor but, the board-arrival sensor on the out-
conveyor has not detected the arrival of the board within the given time. The board that was unloaded
from the pallet unloader has not arrived at the out-conveyor in the given time. X060: OUT ARRV CHK
does not come on (QP132).
Remedy: Check that the board has not been caught up somewhere on the conveyor.
------------------------------
Code: 15040406
Display: OUT_CNV_PCB_EXIST
Used by: CP-732E, CP-742ME, CP-742E
Cause: A board exists in front of the board being unloaded.
Remedy: Make sure that there is not an error in the operation of the out-conveyor board arrival check
sensor of the manipulator.
------------------------------
第 1133 页
Code: 15040410
Display: Out-carrier advance limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier has deviated from the advance limit position.
Remedy: Check the out-carrier position. If the out-carrier is at the prescribed advance limit position,
check the out-carrier's advance limit sensor. If the out-carrier is not at the prescribed advance limit
position, move the out-carrier to its advance limit position.
------------------------------
Code: 15040411
Display: Out-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier close limit sensor failed to switch on. An out-carrier close was executed to advance
the out-carrier from its retract limit position but the open confirmation sensor at the advance limit side
failed to switch off within the prescribed period of time. Alternatively, an out-carrier close was executed to
retract the out-carrier from its advance limit position but the open confirmation sensor at the retract limit
side failed to switch off within the prescribed period of time.
Remedy: Check to see if the out-carrier close operation has occurred correctly. Also verify that the out-
carrier close limit sensor is mounted at the correct position.
------------------------------
Code: 15040412
Display: Out-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier open limit sensor failed to switch on.
Remedy: Check to see if the out-carrier open operation has occurred correctly. Also verify that the out-
carrier open limit sensor is mounted at the correct position.
------------------------------
Code: 15040414
Display: Out-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier cannot be advanced, as there is a risk of interference with the panel on the out-lifter
(because it is not known if there is a panel on the out-carrier).
Remedy: Remove the panel from the out-lifter.
------------------------------
Code: 15040415
Display: Out-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier cannot be retracted, as there is a risk of interference between the panel on the out-
carrier and the panel on the out-lifter.
Remedy: Remove the panel from the out-lifter.
------------------------------
Code: 15040416
Display: Out-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier cannot be retracted, as there is a risk of interference with the panel on the out-lifter
(because it is not known if there is a panel on the out-carrier).
Remedy: Remove the panel from the out-lifter.
------------------------------
Code: 15040417
Display: Out-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier clamper's close limit (clamp limit) sensor failed to switch on.
第 1134 页
Remedy: The clamper must be closed in order to move the XY-table to the middle loading position. Check
to see if the out-carrier clamper is closed. If closed, and if this error occurs anyway, adjust the sensor
mounting position.
------------------------------
Code: 15040418
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carriers advance limit and retract limit sensors are both off.
Remedy: Move the out-carrier to either the advance limit or the retract limit position. If this error still
occurs, adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their
mounting positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040419
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier's advance limit and retract limit sensors are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041A
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's advance limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041B
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's advance limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041C
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's retract limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041D
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's retract limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041E
Display: Out-carrier panel conveyance error.
第 1135 页