Used by: Cause: The mask fiducial mark sequence has not been positioned properly. Remedy: Check the sequences starting with the one for which the error displayed. The order of the sequences should be as follows: mask fid…
Code: 2100F032
Display: Black_or_white data error in mark_data
Used by:
Cause: There is an entry error in the B/W section of mark_data.
Remedy: Input either "B" or "W" in this section.
------------------------------
Code: 2100F033
Display: L/S error in mark_data
Used by:
Cause: There is an error in the L/S section of the mark_data.
Remedy: Input either "L" or "S" in the L/S section.
------------------------------
Code: 2100F034
Display: Part data not found
Used by:
Cause: The Part data was not found for a certain device.
Remedy: Check that the Part data file has Part data for the device on which the error occurred.
------------------------------
Code: 2100F035
Display: This component hight is over range
Used by:
Cause: The part height entered in the program for the FCP-2/3 is too high. The maximum allowable
heights are 4.5 mm (FCP-2) and 6.0 mm (FCP-3).
Remedy: Check the appropriate device in Part data.
------------------------------
Code: 2100F036
Display: This component should be set befor the 4.5mm hight
Used by:
Cause: On the FCP-3, a part higher than 4.5 mm is followed by a part lower than 4.5 mm.
Remedy: Correct the order of the sequence.
------------------------------
Code: 2100F037
Display: Mask sequence is out of order
Used by: GP2,GP3
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F038
Display: Block0 fidutial sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F039
Display: Block 0 block skip sequence is out of order
第 2105 页
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03A
Display: Block skip sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03B
Display: Fiducial sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03C
Display: Memory allocation error
Used by:
Cause: Memory space could not be allocated.
Remedy: Contact Fuji.
------------------------------
Code: 2100F03D
Display: Holder number is not definition
Used by:
Cause: The holder number is undefined.
Remedy: Input the holder number under the HM heading in the second page of sequence data.
------------------------------
Code: 2100F03E
Display: Beyond the limits of holder number
Used by:
Cause: A number outside the correct range (1-4 on the IP2) was entered.
Remedy: Check that numbers within the correct range have been entered.
------------------------------
Code: 2100F03F
Display: Holder number is not light with device number
Used by:
Cause: The holder number and the device number are not matched correctly.
Remedy: On the IP2, holder 1 covers devices 1 ~ 37 and 101 ~ 110, holder 2 covers devices 4 ~ 37, holder
3 covers devices 51 ~ 84 and holder 4 covers devices 51 ~ 87. Check that the holder number is not
specified outside this range.
------------------------------
第 2106 页
Code: 2100F040
Display: Not set up holder in PCT
Used by:
Cause: This is a system error.
Remedy: Re-install the software.
------------------------------
Code: 2100F041
Display: D_No. Pd **** Undefined Generic device data
Used by:
Cause: The **** generic device data item is undefined.
Remedy: Check the device that produced the error, and check that there is a GD file.
------------------------------
Code: 2100F042
Display: Undefined nozzle_assignment_table name
Used by:
Cause: The input nozzle assignment table name is undefined.
Remedy: Enter the nozzle assignment table name under the Nozzle_assignment_table heading of
Machine_data of the production program in use.
------------------------------
Code: 2100F043
Display: Nozzle_assignment_table not existed
Used by:
Cause: The nozzle assignment table does not exist.
Remedy: Create a nozzle assignment table.
------------------------------
Code: 2100F044
Display: Next device data rooping error
Used by:
Cause: An error occurred in the next device data loop.
Remedy: The next device numbers must eventually form a loop (i.e., return to the original device). Check
that this is the case.
------------------------------
Code: 2100F045
Display: This next device is on different pallet
Used by:
Cause: This next device is on another pallet.
Remedy: On the CP5, the next devices must all be on the same pallet.
------------------------------
Code: 2100F046
Display: Nozzle table does not match M/C type
Used by:
Cause: The nozzle assignment table is different from the machine type.
Remedy: Check the nozzle assignment table. Input the same nozzle assignment table name's machine
type under the program's "Nozzle_assignment_table" heading.
------------------------------
Code: 2100F047
Display: Nozzle_assignment_table file open error
Used by:
Cause: The nozzle assignment table could not be opened.
Remedy: Check the nozzle assignment table. Input the same nozzle assignment table name's machine
type under the program's "Nozzle_assignment_table" heading.