FUJI错误代码查询.pdf - 第127页

Remedy: Set the indexing type in the program header to one of the following values: 0, 2, 3, 4, or 5. These settings indicate 7-inch indexing, 5-2 indexing, 4-3 indexing, 3-4 indexing, and 2-5 indexing, respectively. ---…

100%1 / 5282
Remedy: When using the MCS, set Pcb_x in the production program. When using F4G, check the value of
General PCB Data X. Refer to the board length in the FQP1. In order to position the board in the pallet,
the correct board length (tolerance within +-0.5 mm) must be specified.
------------------------------
Code: 1101E028
Display: 1101E028
Used by: QP132
Cause: The board width is not specified (FQP1).
Remedy: When using the MCS, set Pcb_y in the production program. When using F4G, check the value of
General PCB Data Y. If a board with a different width is detected on the FQP1 it is unloaded. For this
reason the board width must be entered. Board width is judged to be different if the current board width
differs from the previous board width by more than +-0.5 mm.
------------------------------
Code: 1101E029
Display: 1101E029
Used by: QP132
Cause: The board thickness is not specified (FQP1).
Remedy: When using F4G, check the value of General PCB Data Thickness in the production program.
On the FQP1, the reference point for the pickup nozzles is taken as the lower surface of the board.
Therefore, the board thickness must be input.
------------------------------
Code: 1101E02A
Display: Same as code
Used by: QP132
Cause: The rotation angle specified for board setup in the program header is outside the valid range.
This error occurs when the program is checked upon transmission.
Remedy: Set the rotation angle for board setup in the program header to 0 to load the board without
rotation, or 3 to load with rotation.
------------------------------
Code: 1101E02B
Display: Same as code
Used by: QP132
Cause: The multiple board loading flag in the program header is outside the valid range. This error
occurs when the program is checked upon transmission.
Remedy: Set the multiple board loading flag in the program header to 0 or 1 when loading a single board,
or to 2 for tandem loading.
------------------------------
Code: 1101E02C
Display: Same as code
Used by: QP132
Cause: The number of blocks per board has not been set even though the multiple board loading flag in
the program header indicates that tandem loading is to be performed. This error occurs when the
program is checked upon transmission.
Remedy: Set the number of blocks per board when the multiple board loading flag in the program header
indicates that tandem loading is to be performed.
------------------------------
Code: 1101E02D
Display: Same as code
Used by: QP132
Cause: The value of the indexing type parameter in the program header is outside the valid range. This
error occurs when the program is checked upon transmission.
第 126 页
Remedy: Set the indexing type in the program header to one of the following values: 0, 2, 3, 4, or 5. These
settings indicate 7-inch indexing, 5-2 indexing, 4-3 indexing, 3-4 indexing, and 2-5 indexing, respectively.
------------------------------
Code: 1101E02E
Display: Same as code
Used by: QP132
Cause: Different indexing types are specified for programs having the same family name.
Remedy: Change the family name, or set the indexing types to the same value.
------------------------------
Code: 1101E02F
Display: Same as code
Used by: QP132
Cause: Unexecutable sequences have occurred because the indexing type in the program header has
been set to 7-inch single indexing. This error occurs when the program is checked upon transmission.
Remedy: Check the mounting coordinates in the sequence data. If the coordinates are correct, set the
indexing type in the program header to a value other than 0.
------------------------------
Code: 1101E030
Display: Same as code
Used by: QP132
Cause: A family name has not been set in the program header. This error occurs when the program is
checked upon transmission.
Remedy: Set a family name in the program header.
------------------------------
Code: 1101E031
Display: Same as Code.
Used by: QP132
Cause: The value set for the loading distance position for tandem loading ("PCB distance") has been set to
a positive value.
Remedy: Set this item to a negative value.
------------------------------
Code: 1101E032
Display: 与编码相同
Used by: GP551,GP6,GPX,NXTP
Cause: 特殊清洁计数器超出范围。
Remedy: 请确认生产程序的Special_cleaning_interval。
范围:0~65000[块]
请确认FujiFlexa上设定的特殊自动清洁计数器。
范围:0~9999[块](GPX,NXTP)
自动清洁为0块时,不能对特殊清洁进行1块以上的设定(GPX,NXTP)。
------------------------------
Code: 1101E033
Display: Same as code
Used by: GP2,GP3,GP551,GP6
Cause: The pressure measurement interval setting is outside the valid range.
Remedy: Make sure that the "Press_meas_interval" parameter in the production program is set to a value
from 0 to 65000 [boards].
------------------------------
Code: 1101E034
Display: Same as code
Used by: GP551,GP6
第 127 页
Cause: The solder supply speed setting is outside the valid range.
Remedy: Make sure that the solder supply speed setting in the production program is from 0 to 200
[mm/sec]. If a value of 0 has been set in the production program, check the solder supply speed setting in
the Proper data.
------------------------------
Code: 1101E035
Display: Same as code
Used by: GP2,GP3,GP551,GP6
Cause: Squeegee/Pressure Rear, Squeegee/Pressure Front, or Squeegee/Solder Low Limit at the
production program is out of range.
Remedy: Verify the data input range for the production program.
Squeegee/Pressure Rear: 0.10 to 9.99
Squeegee/Pressure Front: 0.10 to 9.99
Squeegee/Solder Low Limit: -9.99 to -0.10
The following are the ranges at machines with a max. print pressure of 20-kg.
Squeegee/Pressure Rear: 0.10 to 20.0
Squeegee/Pressure Front: 0.10 to 20.0
------------------------------
Code: 1101E036
Display: Same as code
Used by:
Cause: The value specified at the item "Solder_supply_stroke" in the production program is outside the
acceptable range.
Remedy: Check the value set in item "Solder_supply_stroke" of the production program. The acceptable
range is 1-510 [mm]. (For GP-6 single squeegee machines the acceptable range is 1-420 [mm] and for
double squeegee machines the acceptable range is 1-460 [mm]. For GP-5 single squeegee machines the
acceptable range is 1-320 [mm] and for double squeegee machines the acceptable range is 1-360 [mm].)
------------------------------
Code: 1101E037
Display: Same as code.
Used by:
Cause: Size_x and Size_y values have not been set in mark data despite the fact that the production
program contains block skip marks.
Remedy: Retransmit the program after setting the Size_ x and Size_y values in mark data.
------------------------------
Code: 1101E038
Display: 与该编码相同
Used by: GP551,GP6,GPX,NXTP
Cause: 生产程序的Screen Status为规定外。
网版类型为范围外。(GPX,NXTP)
Remedy: 请确认生产程序的数据Screen Status。
GP6的框设定如下所示。
新FUJI框:0000 0000 0000 0001 (1H)
其他公司框/旧FUJI框网版更换完毕:0000 0000 0000 0000 (0H)
旧FUJI框网版无更换:0000 0000 0000 1000 (8H)
可以设定的网版类型如下所示。
·0:650x680mm
·1:550x650mm(GP6框,NXTP-M35)
·2:650x550mm
·3:23英寸四方形
·4:29英寸四方形