FUJI错误代码查询.pdf - 第2152页

Display: When using [Fix Feeders], there is no such slot available for the tray. Used by: Cause: The specified stage - slot number does not exist. Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTST…

100%1 / 5282
------------------------------
Code: 2305000B
Display: For the item [Interval of Mount Height in order from lowest to highest], an illegal value was input
for [High Density Circuit Board].
Used by:
Cause: At the Optimize Condition Settings screen, under the item [Interval of Mount Height in order from
lowest to highest], a the setting entered in [Mount in 0.1mm Intervals up to ***mm (High Density Circuit
Board)] is not a numeric value.
Remedy: Enter a numeric value.
------------------------------
Code: 2305000C
Display: For the item [Interval of Mount Height in order from lowest to highest], the input value for [High
Density Circuit Board] is out of range (0 to 2.0).
Used by:
Cause: At the Optimize Condition settings screen, under the item [Interval of Mount Height in order from
lowest to highest], the setting entered in [Mount in 0.1mm Intervals up to ***mm (High Density Circuit
Board)] is out of range (0 to 2.0).
Remedy: Enter a value within the input range.
------------------------------
Code: 2305000D
Display: The Alt. Feeder does not exist. Do you want to set 0 for alternate feeder?
Used by:
Cause: A feeder is not set in the Alt. Feeder specified for the displayed stage - slot.
Remedy: The Feeder Setup information in the program file is incorrect. Check the settings.
------------------------------
Code: 2305000E
Display: There are too many feeders allocated to one stage.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of feeders allocated to the stage exceeded the maximum feeder slots.
Remedy: Firstly, try changing the [Use feeder type] settings.
If unsuccessful, perform optimization using the [Alt. Feeders are Removed] setting.
If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 2305000F
Display: There are too many trays allocated to one pallet.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of trays allocated to one pallet exceeded the maximum tray slots.
Remedy: Firstly, try changing the [Arrange Trays on the Pallet] setting to [Give Priority to Number of Kinds
over Speed (Allots two part kinds to one pallet)].
If unsuccessful, perform optimization using the [Alt. Feeders are Removed] setting.
If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 23050010
Display: A currently unused feeder has been fixed, however, no part data exists for that slot.
Used by:
Cause: There is no part data displayed in the Feeder Setup.
Remedy: The program file data is incorrect. Check the contents.
------------------------------
Code: 23050011
第 2151 页
Display: When using [Fix Feeders], there is no such slot available for the tray.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050012
Display: When using [Fix Feeders], there is no such slot available for the feeder.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050013
Display: When using [Fix Feeders], a feeder is too wide to place at an end slot was specified.
Used by:
Cause: In the program's feeder setup, a feeder too wide to place at an end slot was specified.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050015
Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close
to the feeder to the left.
Used by:
Cause: In the program's feeder setup, a feeder wide enough to interfere with the adjacent feeder on the
left side.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050018
Display: A feeder included in fixed feeder processing is too wide to be loaded on the stage.
Used by:
Cause: A tray included in fixed feeder processing is too wide to be loaded in the pallet.
Remedy: In the part data, check the tray length (PARTS/PACKCLS/PPCTRDX) and the tray width
(PARTS/PACKCLS/PPCTRDY) settings.
------------------------------
Code: 23050019
Display: A tray included in fixed feeder processing is too wide to be loaded side by side in the pallet.
Used by:
Cause: When the tray specified in the program file is placed alongside another tray in the pallet, the
combined tray width exceeds the pallet width.
Remedy: In the program file's feeder setup, check the stage number (PROGRAM/DEVICE+/GUTSTN) and
slot number (PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder
Arrangement] setting for optimization.
------------------------------
Code: 2305001A
Display: Are you finished?
第 2152 页
Used by:
Cause: The confirmation dialog displays at each time of completion.
Remedy: Select [Yes] to finish. Select [No] to continue.
------------------------------
Code: 2305001B
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, or optimization process has completed, but the optimized
program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
When attempting to open the program file, select [No] to abandon the optimized program, and display the
dialog for selecting a new program file to be optimized.
When optimization process has completed, select [No] to exit without saving the optimized program.
------------------------------
Code: 2305001C
Display: No nozzle is registered.
Used by:
Cause: No valid nozzle match could be made between the Nozzle Config. file's NCFTYPE and the Nozzle
Spec. file乫s NSPNAME.
Remedy: There is a problem with either or both files. Normally, the Nozzle Config. and Nozzle Spec. files
in the MCS-X default directory are read automatically. Check that both files contain correct data. When
starting up the optimizer, in cases where prompted to specify a file because the default file cannot be
found, check the file contents and correct if necessary.
------------------------------
Code: 2305001D
Display: Nozzle Configuration File "Fujinzl.cfg" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 2305001E
Display: The contents of Nozzle Configuration File are empty.
Used by:
Cause: The Nozzle Config. file is empty.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2305001F
Display: Contents are not Nozzle Configuration File.
Used by:
Cause: The field "UNIT", "NZLCONF" does not exist.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050020
Display: Cannot read the file.
第 2153 页