FUJI错误代码查询.pdf - 第2201页
Used by: Cause: "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" data in the specified production program was read and the "GUTPDN" part data name was too long. The file name is ab…
Cause: An out of range value was detected for "GUTSLTN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read. At present this error does not occur.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1057
Display: "GUTDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read. At present this error does not occur.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1058
Display: "GUTNSTN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNSTN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1059
Display: "GUTNSLTN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNSLTN" in the "BLOCK", "DEVICE+" data when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1060
Display: "GUTNDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1061
Display: "GUTPDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTPDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line. "GUTPDN" is a mandatory item.
------------------------------
Code: 51??1062
Display: Part data name for "GUTPDN" is too long.
第 2200 页
Used by:
Cause: "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" data in the specified production program was read
and the "GUTPDN" part data name was too long. The file name is abbreviated to its maximum length
when downloaded.
Remedy: Check the "GUTPDN" setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1070
Display: "GSQSSLTN"value out of range.
Used by:
Cause: An out of range value was detected for"GSQSSLTN"in the"BLOCK","SEQUENCE+"data
when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","SEQENCE+"in the production program.
Normally the sequence number in which the error occurred is reported to the supplementary information
line. Check this line.
------------------------------
Code: 51??1071
Display: No"GUTSSLTN"item declaration.
Used by:
Cause: No"GUTSSLTN"entry was found in the item declaration line
in"BLOCK","DEVICE+"when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the"GUTSSLTN"setting in the item declaration line in"UNIT","PROGRAM"-
"BLOCK","DEVICE+"in the production program. "GUTSSLTN"is a mandatory item.
------------------------------
Code: 51??1072
Display: "GUTSSLTN"value out of range.
Used by:
Cause: An out of range value was detected for"GUTSSLTN"in the"BLOCK","DEVICE+"data
when"UNIT","PROGRAM"in the specified production program was read. At present this error does not
occur.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program.
------------------------------
Code: 51??1073
Display: "GUTNSSLT"value out of range.
Used by:
Cause: An out of range value was detected for"GUTSSLTN"in the"BLOCK","DEVICE+"data
when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program.
Generally the stage number,slot number,sub slot number in which the error occurred is reported to the
supplementary information line.
------------------------------
Code: 51??1074
Display: Invalid combination of sub slot numbers found.
Used by:
Cause: Both a zero and a non-zero value exist for the same slot of the same stage in the specified
program.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"or"UNIT","PROGRAM"-
"BLOCK","SEQUENCE+"in the production program. Generally the sequence number at which the error
occurred is reported to the supplementary information line if the problem was found in
the"SEQUENCE+"section. If the problem lies in the "DEVICE+"section,the stage number,slot number and
第 2201 页
sub slot number in which the error occurred is generally reported to the supplementary information line.
------------------------------
Code: 51??1100
Display: Unused sequence data.
Used by:
Cause: In "BLOCK", "SEQUENCE+" in "UNIT", "PROGRAM" in the specified production program, there are
sequence lines with "GSQSN" values (the sequence numbers) which exceed the specified "GSMSQQ" value
(the number of sequences in the program).
Remedy: Check the data settings for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the specified
production program. Furthermore, check that the setting for "GSQSMM" in "UNIT", "PROGRAM" -
"BLOCK", "PGHEAD-" is correct.
------------------------------
Code: 51??1101
Display: Out of range sequence data.
Used by:
Cause: In "BLOCK", "SEQUENCE+" in "UNIT", "PROGRAM" there are sequence lines with "GSQSN" values
which are invalid for the applicable machine type.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program.
------------------------------
Code: 51??1102
Display: Multiply defined sequence data.
Used by:
Cause: An attempt was made to read a sequence number in "BLOCK", "SEQUENCE+" in "UNIT",
"PROGRAM" in the production program but the data line for this sequence number was multiply defined.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program.
------------------------------
Code: 51??1110
Display: Unused device data.
Used by:
Cause: In "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the specified production program, the reported
device line is not referred to in "BLOCK", "SEQUENCE+".
Remedy: Check the data setting in "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Also check the data setting in "UNIT", "PROGRAM" - "BLOCK", "DEVICE+".
------------------------------
Code: 51??1111
Display: Out of range device data.
Used by:
Cause: In "BLOCK", "DEVICE+" in "UNIT", "PROGRAM" there are device lines with "GUTSTN", "GUTSLTN"
values or "GUTDN" values which are invalid for the applicable machine type.
Remedy: Check the data settings for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1112
Display: Multiply defined device data.
Used by:
Cause: In "BLOCK", "DEVICE+" in "UNIT", "PROGRAM" the data lines for the reported device are multiply
defined.
Remedy: Check the data settings for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
第 2202 页