FUJI错误代码查询.pdf - 第2181页
Code: 230A3307 Display: Total number of balls must be at least 12. Used by: PDW Cause: The number of balls specified in element data is less than 12. Remedy: Input element data to increase the number of balls to 12 or mo…
Remedy: Input an element with 5 or more leads.
------------------------------
Code: 230A3206
Display: No leads were found.
Used by: PDW
Cause: Lead pins could not be recognized in semi-automatic input.
Remedy: Specify the correct recognition range.
------------------------------
Code: 230A3207
Display: Unexpected error
Used by: PDW
Cause: An unidentified error occurred before recognition.
Remedy: Check that the element data and template are correct.
------------------------------
Code: 230A3301
Display: Recognition error.
Used by: PDW
Cause: An error occurred during image recognition.
Remedy: Input element data that can be recognized.
------------------------------
Code: 230A3302
Display: Maximum input level reached.
Used by: PDW
Cause: More than 128 ball elements have been input.
Remedy: Delete the current element data and specify new element data.
------------------------------
Code: 230A3303
Display: Unable to adjust pitch.
Used by: PDW
Cause: The average pitch X/Y of the values being edited is 0.
Remedy: Input element data that can be recognized.
------------------------------
Code: 230A3304
Display: No element data.
Used by: PDW
Cause: No elements have been input.
Remedy: Input element data.
------------------------------
Code: 230A3305
Display: Requires an element with 2 or more adjacent balls.
Used by: PDW
Cause: Recognition/compensation cannot be completed because there are no recognizable adjacent balls
in the element data.
Remedy: Check that the element data is correct.
------------------------------
Code: 230A3306
Display: Unexpected error
Used by: PDW
Cause: An unidentified error occurred before recognition.
Remedy: Check that the element data and template are correct.
------------------------------
第 2180 页
Code: 230A3307
Display: Total number of balls must be at least 12.
Used by: PDW
Cause: The number of balls specified in element data is less than 12.
Remedy: Input element data to increase the number of balls to 12 or more.
------------------------------
Code: 230A3308
Display: Requires an element with 2 or more balls.
Used by: PDW
Cause: None of the input elements have 2 or more balls.
Remedy: Input an element with 2 or more balls.
------------------------------
Code: 230A4000
Display: Cannot perform vision test.
Used by: PDW
Cause: Failed to compile the edited template.
Remedy: Carry out the template editing again.
------------------------------
Code: 230A4001
Display: Cannot read Debug Information.
Used by: PDW
Cause: Could not read one of either the PDS, image, template or debug data files.
Remedy: Check that you have all the files and they are all in working order.
------------------------------
Code: 230A4002
Display: Filename has invalid characters.
Used by: PDW
Cause: The conditions file name has invalid characters.
Remedy: Change the file name, removing invalid characters.
------------------------------
Code: 31003110
Display: Command_line transmission error
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
Cause: Command line transmission error.
Remedy: Press the [Reset] button. Send the board type information from the machine to the LMS again.
------------------------------
Code: 31003111
Display: SCH. Check DATA TABLE on LMS
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
Cause: There is no data in the production schedule table.
Remedy: Check the LMS production schedule table.
------------------------------
Code: 31003112
Display: DATA Check DATA TABLE on LMS
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
第 2181 页
Cause: There is no reported code data at the LMS.
Remedy: Check the LMS data table.
------------------------------
Code: 31003113
Display: CELL MODE ERROR Check CELL_STATUS
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
Cause: The reported board type is not the same as the board type waiting at the LMS.
Remedy: Check cell status or changeover mode.
------------------------------
Code: 31003114
Display: LMS is BUSY Waiting for LMS edition
Used by: GSP2,GSP3,IP3
Cause: The LMS production schedule table was being prepared when information was reported.
Remedy: Wait for the LMS to finish preparing the production schedule table.
------------------------------
Code: 31003116
Display: 31003116
Used by:
Cause: A command was sent to a passive cell.
Remedy: Check the LMS and the machine cell status settings and enter correct values.
------------------------------
Code: 31003117
Display: 31003117
Used by:
Cause: The status data is out of range.
Remedy: Check the cell status values and enter correct values.
------------------------------
Code: 31003118
Display: 31003118
Used by:
Cause: There is no reserved data.
Remedy: Check the table data, etc. necessary for changeover and then perform changeover again.
------------------------------
Code: 51??0000
Display: Normal ending or normal start.
Used by:
Cause: The command was completed normally or started normally (when using immediate return mode).
Remedy:
------------------------------
Code: 51??0001
Display: Command format error.
Used by:
Cause: One of the following mistakes has been made in the format of the command. Either the
subcommand name is incorrect, the number of arguments is incorrect or an invalid argument has been
specified as the option argument.
Remedy: Check that there are no mistakes in the command format.
------------------------------
Code: 51??0002
Display: Nickname error.
第 2182 页