Code: 11022A29 Display: Same as code Used by: QP242 Cause: No value has been set for the "PLM? Feeding Off Timer (QP2)" parameter, which determines how long feeding by the IP-series feeder is turned off. The va…

100%1 / 5282
Code: 11022A23
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? VP board No. (QP2)" setting (which indicates the number of the vision processing
board that the LSO board is connected to) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set the correct board number (either 1 or 2) for the "PLM? VP board No. (QP2)" parameter in the
Proper data.
------------------------------
Code: 11022A24
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Camera? Scan Speed (QP2)" setting (which indicates the scan speed for the LS camera)
is outside the valid range. The value for the "?" in the parameter name indicates the module number and
camera number.
Remedy: Set the correct value (from 1 to 1000) for the "PLM? Camera? Scan Speed (QP2)" parameter in
the Proper data.
------------------------------
Code: 11022A25
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Scan Offset Pulse (H,M,L) (QP2)" setting (which indicates the offset for the start of
scanning by the LS camera) is outside the valid range. The value for the "?" in the parameter name
indicates the module number.
Remedy: Set the correct value (from 1 to 60000) for the "PLM? Scan Offset Pulse (H,M,L) (QP2)" parameter
in the Proper data.
------------------------------
Code: 11022A26
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the "PLM? Pickup Timer ,2,3 (QP2)" parameter, which determines how
long the head remains lowered during component pickup. The value for the "?" in the parameter
nameindicates the module number.
Remedy: Set a value for the "PLM? Pickup Timer ,2,3 (QP2)" in the Proper data.
------------------------------
Code: 11022A27
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the "PLM? Placement Timer ,2,3 (QP2)" parameter, which determines
how long the head remains lowered during component placement. The value for the "?" in the parameter
name indicates the module number.
Remedy: Set a value for the "PLM? Placement Timer ,2,3 (QP2)" in the Proper data
------------------------------
Code: 11022A28
Display: Same as code
Used by: QP242
Cause: No value has been set for the "PLM? Feeding On Timer (QP2)" parameter, which determines how
long feeding by the IP-series feeder is turned on. The value for the "?" in the parameter name indicates the
module number.
Remedy: Set a value for the "PLM? Feeding On Timer (QP2)" in the Proper data
------------------------------
第 173 页
Code: 11022A29
Display: Same as code
Used by: QP242
Cause: No value has been set for the "PLM? Feeding Off Timer (QP2)" parameter, which determines how
long feeding by the IP-series feeder is turned off. The value for the "?" in the parameter name indicates the
module number.
Remedy: Set a value for the "PLM? Feeding Off Timer (QP2)" in the Proper data
------------------------------
Code: 11022A2A
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX In Convyr Speed (QP2)" setting (which determines the speed of the board conveyer
PX-axis during board loading) is outside the valid range. The value for the "?" in the parameter name
indicates the module number.
Remedy: Set a value from 38 to 1000 for the "PLM? PX In Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2B
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX Out Convyr Speed (QP2)" setting (which determines the speed of the board
conveyer PX-axis during board unloading) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set a value from 38 to 1000 for the "PLM? PX Out Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2C
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX Red Convyr Speed (QP2)" setting (which determines the speed of the board
conveyer PX-axis during board deceleration) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set a value from 5 to 37 for the "PLM? PX Red Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2D
Display: "Data check error [11022A2D]"
Used by: QP242,QP201,QP202,QP203
Cause: The number of the communication port to be used by the ID controller unit either has not been
set, or duplicates another setting.
Remedy: Check the number of the port being used and correct the setting.
------------------------------
Code: 11022A2E
Display: "Data check error [11022A2E]"
Used by: QP242
Cause: The number of the communication port to be used by the tape end sensor either has not been set,
or duplicates another setting.
Remedy: Check the number of the port being used and correct the setting.
------------------------------
Code: 11022A2F
Display: "Data check error [11022A2F]"
第 174 页
Used by: QP242
Cause: The flux cylinder size "PLM? Flux Cylinder Size"(QP2) setting is out of range. "?" represents the
module number.
Remedy: Input a value between 1-1000 for Proper data item, "PLM? Flux Cylinder Size"(QP2).
------------------------------
Code: 11022A30
Display: "Data check error [11022A30]"
Used by: QP242
Cause: The flux pump controller port number "PLM? Pump SCU Port"(QP2) setting is out of range. "?"
represents the module number.
Remedy: Specify the port number for the flux pump controller in Proper data item, "PLM? Pump SCU
Port"(QP2). Available SCU port numbers are 1-3.
------------------------------
Code: 11022A31
Display: Same as code.
Used by: QP242
Cause: The flux type has been specified at Proper data item, "PLM? Flux Dispence Type".
Remedy: Ensure that Proper data item, "PLM? Flux Dispence Type" (APL/CLT) is set to "0".
------------------------------
Code: 11022A32
Display: Same as code.
Used by: QP132
Cause: Proper data settings for heat expansion compensation are not correct.
Remedy: Proper data
485:T_MARK Check Interval
486:T_MARK Check Tolerance
487:Thermal Expansion Compensation
488:T_MARK Check PM No.
Ensure these settings are specified correctly.
------------------------------
Code: 11022A33
Display: Same as code.
Used by: QP242
Cause: The module width and supply unit type are not compatible.
Remedy: Check the setting of the following Proper data items ;
PLM? Module Width
PLM? Device Type
"?" represents the module number.
------------------------------
Code: 11022A34
Display: MX/MY-axis tolerance error.
Used by: QP132
Cause: The Proper data for the MX or MY-axis is not correct. The resolution level of the MX and MY-axis
has been changed from V1.43 and later. This error occurs if an unsuitable value is detected in 1 pulse 5
um mode or 1 pulse 2.5 um mode. Specify 2000H at Proper data item "12: Machine Status B" to set the
resolution mode to 5 um. If this setting is not made, a default setting of 2.5 um is used.
Remedy: Correctly set Proper data for the MX and MY-axis. If the version has been upgraded, double the
setting at the Proper data items listed below, and make the required changes to the servo board switch
settings. Refer to the appropriate upgrade report for further details.
141: Mark Read Position MXC
142: Mark Read Position MYC