FUJI错误代码查询.pdf - 第289页

Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP2,GP2,GP3 Cause: Clear off is finished. Remedy: None. ------------------------------ Code: 12010701 Display: 往复臂运转模式错误 Used by: NXTP Cause: 往复臂不是运转模式 Rem…

100%1 / 5282
请清除生产完成块数。(NP2,QP3)
------------------------------
Code: 12010402
Display: 无
Used by: GSP2,GSP3,GPX,NXTP
Cause: 维修保养计数器到了设定值。 通用计数器递增计数了。 (GPX)
Remedy: 请擦拭网板的反面等维修保养作业,然后重新进入自动运转。(GSP2) 请通过[设定]ー[状态]ー[计数器]进行清
除 (GP6 GP5) 请进行刮刀更换或钢板的更换等必要的对应,将通用计数器清零。(GPX)
<img src="$LKEY_ERRIMG_MC$/12010402.PNG">
------------------------------
Code: 12010403
Display:
Used by: CP3,GL5
Cause: Seq End Stop. Automatic operation is finished.
Remedy: Press the start button and go back into automatic operation.
------------------------------
Code: 12010404
Display: Eject Tray
Used by: IP2
Cause: In a non-matrix tray, parts have run out and the machine stops.
Remedy: Discard the tray.
------------------------------
Code: 12010405
Display: 清洁计数结束
Used by: GPX
Cause: 清洁计数到了设定值。
Remedy: 通过[设定]ー[状态]ー[计数器]进行清除
------------------------------
Code: 12010406
Display: 焊锡供应计数结束
刮刀内焊锡余量不足
Used by: GP551,GPX
Cause: 焊锡供应计数到了设定值。或者,根据余量检测判断出焊锡余量不足。
Remedy: 请进行焊锡供应。请通过[设定]ー[状态]ー[计数器]进行清除。
------------------------------
Code: 12010407
Display: 手动清洁计数结束
Used by: GP551,GPX
Cause: 手动清洁计数到了设定值。
Remedy: 请通过[设定]ー[状态]ー[计数器]进行清除。
------------------------------
Code: 12010408
Display: "Pressure measurement counter limit"
Used by: GP551
Cause: The pressure measurement counter has reached its limit.
Remedy: Enter [SET], [STATUS] , then [COUNTER] to cancel this error.
------------------------------
Code: 12010501
Display: CLEAR OFF COMPLETE
Clear Off Has Been Finished
Clear Off Complete
第 288 页
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP2,GP2,GP3
Cause: Clear off is finished.
Remedy: None.
------------------------------
Code: 12010701
Display: 往复臂运转模式错误
Used by: NXTP
Cause: 往复臂不是运转模式
Remedy: 请将往复臂置于运转模式
------------------------------
Code: 12010702
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12020101
Display: PCM PLC Alarm
Used by: CP5
Cause: The pallet loader control system is down.
Remedy: Contact Fuji.
------------------------------
Code: 12020102
Display: Pallet ID Read Error (FCP5)
Pallet ID could not be Read (FCP651C)
Used by: CP652C
Cause: The ID could not be read. The acquisition of the ID for the pallet on the up-elevator has failed
(FCP651C).
Remedy: Verify that there is nothing abnormal about the pallet at the stand by station. Check that the ID
read position is not misaligned (FCP651C). Replace the ID card if read errors occur frequently. If the
pallet ID card is replaced, be sure that the ID_No. is written (recorded). Refer to the Operation Manual
concerning the ID_No. write Command.
------------------------------
Code: 12020103
Display: Check PPS Error
Used by: CP5
Cause: An error occurred at the PPS.
Remedy: Check the display and remove the cause of the error.
------------------------------
Code: 12020104
Display: PPS AUTO Mode Error
Used by: CP5
Cause: A pallet movement request was sent to the PPS when PPS was not in automatic mode.
Remedy: Start the PPS automatic mode.
------------------------------
Code: 12020105
Display: Plt Clear off to PPS Error
Used by: CP5
Cause: A request was made from PCM to PPS to unload pallets. The lower conveyor of the PPS was not
empty.
Remedy: Remove the pallet from the PPS lower conveyor.
第 289 页
------------------------------
Code: 12020106
Display: Plt Clear Off To PPS Error
Used by: CP5
Cause: A request was made from PCM to PPS to unload pallets. The lower conveyor of the PPS was not
empty.
Remedy: Remove the pallet from the PPS lower conveyor.
------------------------------
Code: 12020107
Display: Check PCM R_Conveyor
Used by: CP5
Cause: An error was received from the PCM return conveyor.
Remedy: Check the PCM error display and remove the cause of the error.
------------------------------
Code: 12020108
Display:
Used by: CP5
Cause: The PCM is in manual operation, or the in and out elevator pallet arrived sensor or the pallet
arrived sensor between the out elevator and the PPS is OFF. The permission signal from the PPS to the
out elevator (with a PPS) is OFF.
Remedy: Get the PCM out of manual operation. Check the sensors.
------------------------------
Code: 12020109
Display: Desired Pallet is Not Found
Used by: CP652C
Cause: The PCM or PPS pallets were circulated and a search for the desired pallet was carried out, but
the pallet was not in the machine.
Remedy: Load the pallet to be used in production into the machine.
------------------------------
Code: 12020200
Display: TPU SEQUENCER ERROR
Used by: IP2,IP3
Cause: The digital controller is damaged or the battery is dead.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020201
Display: TPU DEVICE No. ERROR
Used by: IP2,IP3
Cause: An incorrect magazine number was specified.
Remedy: Check the production program.
------------------------------
Code: 12020202
Display: TPU CYCLE NG
Used by: IP2,IP3
Cause: The TPU cycle could not finish.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020203
Display: TPU PICK UP ERROR
Used by: IP2,IP3
Cause: The machine failed to pick parts.
第 290 页