FUJI错误代码查询.pdf - 第737页

Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Unaccepted(PMC Error)" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: The command could not be executed becau…

100%1 / 5282
Cause: The specified angle for the Q-axis is outside the acceptable range.
Remedy: This error does not usually occur.
------------------------------
Code: 12070?7D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mech chuck is holding part. Cannot carry out zero set." (QP2)
Used by: QP202
Cause: Zero setting cannot be carried out because the mechanical chuck is holding a part.
Remedy: Remove the part from the mechanical chuck.
------------------------------
Code: 12070?7E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mech chuck is holding part. Cannot carry out inching" (QP2)
Used by: QP202,QP203
Cause: Inching cannot be carried out because the mechanical chuck is holding a part.
Remedy: Remove the part from the mechanical chuck.
------------------------------
Code: 12070?7F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Failed to check for part." (QP2)
Used by: QP202
Cause: The check for a part on the mechanical chuck failed because only one of the part check sensors is
ON.
Remedy: If there is a part on the chuck,remove it and turn the vacuum off. if there is no part on the
chuck, the parts confirmation sensor may have mistaken part of the machine for a part. Move the placing
head to its retract position. If the same error persists, the part confirmation sensor may require
adjestment.
------------------------------
Code: 12070?80
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No PMC Parameter" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: No PMC parameters exist.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Retransmit the Proper data from the host computer.
------------------------------
Code: 12070?81
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(Servo Not Ready)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The command could not be executed because the servo was not ready.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: If this error has occurred while another error is in effect, clear the cause of that error then press
the RESET switch and restart the machine. If this error recurs, determine the reason that servo power is
not being supplied to the PMC.
------------------------------
Code: 12070?82
第 736 页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(PMC Error)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command could not be executed because the machine is stopped due to a PMC error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, then use commands to dump parts. If the problem
occurs again, use a reset-start to transmit the control software to the PMCs. If the problem occurs again,
faulty hardware such as the PMC control board, servo amps or servo boards may be the cause.
------------------------------
Code: 12070?83
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sequence Number Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Sequence number error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMC. If the problem is recurring, issues such as a
faulty production program or PMC control board may be the cause.
The maximum number of sequences per production program is 5000, and the maximum number of
sequences for a PLM (PM), including mark sequences is 1000.
------------------------------
Code: 12070?84
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Seq Rationality Check Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Sequence rationality check error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program, and execute flush out processing. If the problem occurs again,
retransmit the control software to the PMCs
------------------------------
Code: 12070?85
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Req Command (ST Not Conect)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A handy terminal command request was issued even though there is no handy terminal
connected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?86
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 737 页
"Zero Set Not Complete" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Coplanarity error(NP2,QP3)
Used by: QP242,QP201,QP202,QP203,QP132,NP2,QP3
Cause: The command could not be executed because zero setting has not been completed. This error
also occurs if power to the PMC is turned off and on again after the machine is restarted following
completion of zero setting.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
The LLL zero setting has not been completed.(NP2,QP3)
Remedy: Execute zero setting.
Perform a zero setting operation.(NP2,QP3)
------------------------------
Code: 12070?87
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Axis Incorrectly Specified" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis to perform an action has been incorrectly specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?88
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mach Stop Due to Vision Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The machine has stopped due to a vision processing error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Remove the cause of the vision processing error, press the RESET switch, and restart the
machine.
------------------------------
Code: 12070?89
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mach Stop Due to Recv Count" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The machine has stopped after performing the maximum number of recoveries.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Remove the cause of the recoveries, press the RESET switch, and restart the machine.
------------------------------
Code: 12070?8A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Prog Trans before Request" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
第 738 页