FUJI错误代码查询.pdf - 第1088页
Display: PCB Transport Error: Prev. Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3 Cause: The time required to transport the board between each conveyor exceeded the preset limit. The appropriate setting is made (1:ON 2:OFF 3:O…
------------------------------
Code: 14050002
Display: 在周期自动补正中Corner Dog的影像处理失败。
Used by: XP241,XP341,XP142,XP242
Cause: 在周期自动补正中Corner Dog的影像处理失败。
Remedy: 请用[维修保养C]->[Corner Dog调整]进行影像处理的确认。
有错误时,请确认Corner dog是否有污垢、伤痕或缺陷。
------------------------------
Code: 14050003
Display: 测定吸取位置失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 以吸取位置测定进行地供料器的送料孔的影像处理失败。
Remedy: 请确认是否安装供料器。
请确认料带导盖是否脱离。
请确认料带是否正确地装入。
------------------------------
Code: 14050004
Display: 在周期自动补正中校正尺芯片的影像处理失败。
Used by: XP141,XP142
Cause: 在周期自动补正中量规芯片的影像处理失败。
Remedy: 请确认量规芯片的污垢、尺寸。
------------------------------
Code: 14050005
Display: 在周期自动补正中玻璃校正尺的影像处理失败。
Used by: XP241,XP341,XP242
Cause: 在周期自动补正中玻璃量规的影像处理失败。
Remedy: 请确认玻璃量规的污垢、尺寸。
------------------------------
Code: 15010001
Display: Status of brd unknown
Used by: CP643
Cause: It is unclear which board production method (single board production or double board
production) is in effect.
Remedy: Use a production program that specifies a board production method.
------------------------------
Code: 15010003
Display: PCB in loader
Used by: CP643
Cause: There is a board in the conveyor system(in-conveyor,in-carrier,out-carrier,out-conveyor or main
conveyor),operation cannot be continued.
Remedy: Remove the board from the conveyor system.U
------------------------------
Code: 15010004
Display: Conv. PLC Alarm
Loader command error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,GSP5,GP2,GP3,GP551,GP6,IP3
Cause:
Remedy: Contact Fuji.
Turn the machine off,then on again.
------------------------------
Code: 15010101
第 1087 页
Display: PCB Transport Error: Prev.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between each conveyor exceeded the preset limit. The
appropriate setting is made (1:ON 2:OFF 3:OFF). Three seconds after the deceleration point is activated
the board start point is not on, an alarm occurs and the machine is stopped.
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010102
Display: PCB Stopper Error: Prev.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010103
Display: Command Error: Prev.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010104
Display: Conv. PLC Alarm: Prev.
Used by: CP5,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
Remedy: Contact Fuji.
------------------------------
Code: 15010201
Display: PCB Transport Error: MCID
Chk brd conveyance at MCID
Used by: CP5,CP6,CP6M,CP65,CP642,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between the MCID conveyors exceeded the preset limit.
The appropriate removal setting between conveyors is made (1:ON 2:OFF 3:OFF).
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010202
Display: PCB Stopper Error: MCID
Used by: CP5,CP6,CP6M,CP65,CP642,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
第 1088 页
the cancel stopper sensor.
------------------------------
Code: 15010204
Display: Conv. PLC Alarm: MCID
PCB Transport Error:MCID
Deceleration sensor
does not turn on
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3,CP643
Cause:
Remedy:
------------------------------
Code: 15010301
Display: PCB Transport Error: IN-A
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between each conveyor exceeded the preset limit. The
appropriate setting is made (1:ON 2:OFF 3:OFF). Three seconds after the deceleration point is activated
the board start point is not on, an alarm occurs and the machine is stopped.
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010302
Display: PCB Stopper Error: IN-A
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010303
Display: Command Error: IN-A
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010304
Display: Conv. PLC Alarm: IN-A.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
Remedy: Contact Fuji.
------------------------------
Code: 15010401
Display: PCB Transport Error: IN
PCB Transport Error:I_LIFT
Chk brd conveyance at I-lif
Used by: CP4-1,CP4-2,CP4-
第 1089 页