Cause: The fault which it is impossible to recover occurs. Remedy: This error is impossible to detect.Get a trace file and contact FUJI. ------------------------------ Code: 1211004A Display: Coordinate motion error. Use…
Cause: Power out of phase. One of the three phases for the power is not connected.
Remedy: Check to ensure that all wires for the three phases are not broken, or have any shorts.
------------------------------
Code: 12110042
Display: Servo amplifier error.
Used by:
Cause: Watch dog error. Abnormal SERCOS communication has occurred.
Remedy: Check to ensure that the digital operator is not connected.
Contact Fuji if this occurs frequently, because the SERCOS unit could be damaged.
------------------------------
Code: 12110043
Display: Servo amplifier error.
Used by:
Cause: MST, MDT error. SERCOS communication is abnormal.
Remedy: Check the fiber optic connections and make sure the digital operator is not connected.
Contact Fuji if no abnormalities are found, because the SERCOS board could be damaged.
------------------------------
Code: 12110044
Display: Boot timeout.
Used by:
Cause: RTX Servo filter execution file is timeout of boot.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110045
Display: The magnetic pole detection failure.
Used by:
Cause: The execution of the Detected Magnet Pole is timeout.
Remedy: Check to ensure that the linear motor axis is no interference or that the axis movement is not
impeded.
------------------------------
Code: 12110046
Display: Program error.
Used by:
Cause: The specified function is effective only with the linear motor.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110047
Display: The magnetic pole detection failure.
Used by:
Cause: It has executed magnetic pole detection.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110048
Display: Program error.
Used by:
Cause: An indicated axis is registered on the other operation control at present.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110049
Display: System error.
Used by:
第 872 页
Cause: The fault which it is impossible to recover occurs.
Remedy: This error is impossible to detect.Get a trace file and contact FUJI.
------------------------------
Code: 1211004A
Display: Coordinate motion error.
Used by:
Cause: The draw time of the specified diagram is too long.
Remedy: Check the diagram information.Contact Fuji if no abnormalities are found, and get a trace file.
------------------------------
Code: 1211004B
Display: Profile error.
Used by:
Cause: The profile could not be made as specified.
Remedy: Check to ensure that there is no interference or that the axis movement is not impeded.
Contact Fuji if no abnormalities are found.
------------------------------
Code: 1211004C
Display: Coordinate motion error.
Used by:
Cause: The coodinate motion of the specified handle isn't declarative in the use.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110050
Display: Board error.
Used by:
Cause: The servo board set in the servo initialization file is not supported.
Remedy: Check the setting in the servo initialization file, and that the servo control board is correct.
Contact Fuji if no abnormalities are found, because the board could be damaged.
------------------------------
Code: 12110051
Display: Failed to create object.
Used by:
Cause: Failed to create a servo object.
Remedy: Reinstall the software because the initial installation could have failed.
Contact Fuji if this error is not corrected, because the servo control board could be damaged.
------------------------------
Code: 12110052
Display: Abnormal parameter.
Used by:
Cause: The ADC number setting does not exist.
Remedy: Check the value in the servo initialization file.
If no abnormalities are found, reinstall the software.
------------------------------
Code: 12110053
Display: Abnormal parameter.
Used by:
Cause: An invalid value has been set in the parameter's argument (axis number).
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12110054
Display: Abnormal parameter.
第 873 页
Used by:
Cause: The setting for the servo controller board number is incorrect.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12110055
Display: Abnormal parameter.
Used by:
Cause: The acceleration time setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12110056
Display: Abnormal parameter.
Used by:
Cause: The deceleration time setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12110057
Display: The jerk ratio setting is outside the valid range (1-100).
Used by:
Cause:
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12110058
Display: Abnormal parameter.
Used by:
Cause: The position parameter setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12110059
Display: Abnormal parameter.
Used by:
Cause: The GAIN table setting (Moving带归Settling带幩is invalid.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1211005a
Display: Abnormal parameter.
Used by:
Cause: The GAIN table number setting is invalid.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1211005b
Display: Abnormal parameter.
Used by:
Cause: The traveling speed setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1211005c
Display: Abnormal parameter.
Used by:
Cause: Unable to reference the gain table as the specified axis number is invalid.
Remedy: Reinstall the software because the initial installation could have failed.