FUJI错误代码查询.pdf - 第1132页

------------------------------ Code: 15040349 Display: Panel Set Error Used by: CP-732E, CP-742ME, CP-742E Cause: There is not the pallet on the XY-table in the position indicated. Remedy: Lower the Z-axis to its lower l…

100%1 / 5282
Code: 15040344
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: While waiting for the next panel, either the XY-table panel speed reduction sensor (X0AE) or the
XY-table panel arrival
sensor (X0AF) detected a panel.
While waiting for a signal from the next machine, either the XY-table panel speed reduction sensor, (X0AE)
and the panel arrival
check sensor (X0AF) was deactivated (OFF).
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properl
------------------------------
Code: 15040345
Display: Main-conveyor panel loading error
Used by: CP-752E
Cause: When a panel is detected on the conveyor, the conveyor loads the panel.
If a panel is not detected on the conveyor the conveyor attempts to unload the panel.
Remedy: Check that the XY-table panel speed reduction and panel arrival sensors are functioning
properly.
------------------------------
Code: 15040346
Display: Main-conveyor Stopper Error
Used by: CP-752E
Cause: One of the following errors has occurred:
The machine output the "lower stopper" signal, however the XY-table stopper lower end sensor (X0AA) did
not activate (ON).
Both the XY-table stopper upper end sensor (X0AA), and the XY-table lower end sensor (X0A9) did not
activate (ON) within the spe
cified time limit.
Both the XY-table stopper upper end sensor (X0AA), and the XY-table lower end sensor (X0A9) did not
deactivate (OFF) within the
specified time limit.
Remedy: Check that the stopper is functioning properly, if the error continues. Check that both of the
sensors带幨X0AA, X0A9带幩ar
e functioning properly.
------------------------------
Code: 15040347
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: The XY-table panel arrival sensor (X0AF) was activated before the XY-table panel speed reduction
sensor (X0AE).
Remedy: Check that the main-conveyor panel speed reduction sensor is functioning properly and confirm
the panel status.
------------------------------
Code: 15040348
Display: Panel Set Error
Used by: CP-732E, CP-742ME, CP-742E
Cause: There is not the pallet on the XY-table in the position indicated.
Remedy: Lower the Z-axis to its lower limit position and then clear the in-carrier clamper related error.
Set the pallet on the XY-table in the position indicated.
第 1131 页
------------------------------
Code: 15040349
Display: Panel Set Error
Used by: CP-732E, CP-742ME, CP-742E
Cause: There is not the pallet on the XY-table in the position indicated.
Remedy: Lower the Z-axis to its lower limit position and then clear the out-carrier clamper related error.
Set the pallet on the XY-table in the position indicated.
------------------------------
Code: 1504034A
Display: 电路板位置异常
Used by: GPX
Cause: 在载入侧搬运轨道无法搬运的位置上有电路板。
Remedy: 请除去电路板然后重新放入。
<img src="$LKEY_ERRIMG_MC$/EI0002.bmp">
------------------------------
Code: 1504034B
Display: 主搬运轨道有电路板错误
Used by: NXTP,GPX-C
Cause: 因为在主搬运轨道上有电路板,所以不进入到下一步的处理。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/1504034B.PNG">
------------------------------
Code: 1504034C
Display: 由于主搬运轨上存在电路板,所以读取电路板支撑块的二维码时出现错误。
Used by: NXTP, GPX-C
Cause: 由于主搬运轨上存在电路板,所以无法读取电路板支撑块的二维码。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/1504034B.PNG">
------------------------------
Code: 15040401
Display: OUT CVYOR INTERLOCK
Used by: IP1,NP132,NP133
Cause: The board on the main conveyor is protruding onto the out-conveyor. Or the board which is on
the out-conveyor is protruding into the pallet unloader .
Remedy: Check the board on the out-conveyor. Adjust the main conveyor board arrival sensor and the
out-conveyor board pass sensor. Check the X034: OUT_PASS_CHK (out-conveyor board pass check)
signal at the I/O map.
------------------------------
Code: 15040402
Display: 周期异常 送出错误 (IP1,IP2) 送出异常(GSP,GL)
电路板送出异常(NP2,QP3)
Used by: GL2,GSP2,GSP3,IP1,IP2,NP2,QP3,GPX,NXTP
Cause: 在从主搬运轨道上排出电路板中,发生了电路板被卡住等的异常。主搬运轨道在排出电路板后,在预定时间
内没有到达下工序。或者,主搬运轨道的电路板确认传感器一直为ON。
在从通过确认点到下工序的之间发生了电路板送出超时。(NP2,QP3) 在主搬运轨道排出电路板之后的预定时间
内,电路板没有到达送出搬运轨道。 (GPX)
Remedy: 请确认从主搬运轨道上送出的电路板。可认为电路板偏离正常的位置,请除去被认为发生异常的电路板。
请保证电路板能够顺畅地送出到下工序。(NP2,QP3) 1.请确认搬运轨道上电路板是否被卡住了。
2.可认为电路板偏离了正常位置,请除去被认为发生了异常的电路板。
3.请确认搬运轨道间的电路板取入是否能顺畅地进行。
3-1.搬运轨道宽度的再调整
第 1132 页
3-2.搬运轨道搬入高度的再调整
4.电路板重(请与本公司的Support联系)
5.电路板薄导致被夹入在搬运轨道皮带和轨道之间(请与本公司的Support联系)
8.到达传感器的故障(请与本公司的Support联系)
9.通孔导致的电路板检测困难(请利用停止块偏移设置)
10.电路板的切口(请利用停止块偏移设置)
11.从主搬运轨道排出时,存在电路板粘在钢板上的可能性。请确认。
12.存在电路板送信号到达后工序之前已经OFF的情况。如果机器内有电路板时请除去。(GPX)
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040402.PNG">
------------------------------
Code: 15040403
Display: CHECK NEXT CONVEYOR
(QP132)NEXT PROCESS NOT COMP
Loader error: 15040403
Used by: CP3,GL2,GSP2,GSP3,IP1,IP2,QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: When the machine was SMEMA compatible, a board was unloaded from the out conveyor, but the
BUSY signal did not turn OFF within the time specified in Proper data's 321.L_send_chk.timer item.
Remedy: Check that the board is not stuck on the conveyor. Increase the time setting in
321.L_send_chk.timer. This change must be saved and transmitted to the machine before it can take
effect.
------------------------------
Code: 15040404
Display: (IP1)LD_ERR: 15040404
(QP132)OUT_CVR PCB NOT ARRV
Loader error: 15040404
Used by: IP1,QP132,NP132,NP133
Cause: The board has been unloaded from the main-conveyor but, the board-arrival sensor on the out-
conveyor has not detected the arrival of the board within the given time. When the SMEMA signals were
used, the board did not arrive at the next machine within the given 30 seconds after being unloaded from
the out-conveyor. The board request signal (PCB_REQ) remains on.
Remedy: Check that the board has not been caught up somewhere on the conveyor.
------------------------------
Code: 15040405
Display: (IP1)LD_ERR: 15040405
(QP132)PCB OUT NOT COMP
Loader error: 15040405
Used by: IP1,QP132,NP132,NP133
Cause: The board has been unloaded from the main-conveyor but, the board-arrival sensor on the out-
conveyor has not detected the arrival of the board within the given time. The board that was unloaded
from the pallet unloader has not arrived at the out-conveyor in the given time. X060: OUT ARRV CHK
does not come on (QP132).
Remedy: Check that the board has not been caught up somewhere on the conveyor.
------------------------------
Code: 15040406
Display: OUT_CNV_PCB_EXIST
Used by: CP-732E, CP-742ME, CP-742E
Cause: A board exists in front of the board being unloaded.
Remedy: Make sure that there is not an error in the operation of the out-conveyor board arrival check
sensor of the manipulator.
------------------------------
第 1133 页