FUJI错误代码查询.pdf - 第495页

Code: 12050182 Display: Shutter 1 Alarm Lower limit sensor error Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643 Cause: An alarm has occurred at the lower-limit sensor for the shutter of the D1-axis. Remedy: Chec…

100%1 / 5282
------------------------------
Code: 1205013?
Display: Nozzle damage has been detected on head 2.
Used by: NP133,NP134,NP153
Cause: The nozzle bend check sensor at head 2, 13ST has detected a nozzle error. The question mark (?)
indicates the nozzle position. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Replace the nozzle, either manually or using the nozzle change command.
------------------------------
Code: 1205014?
Display: A nozzle error has been detected at head 1, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 1, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 1205015?
Display: A nozzle error has been detected at head 2, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 2, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 1205016?
Display: A nozzle catch error has been detected at head 1, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 1, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 1205017?
Display: A nozzle catch error has been detected at head 2, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 2, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 12050180
Display: A vacuum pump thermal error has been detected.
Used by: NP133,NP134,NP153
Cause: The vacuum pump power source breaker was switched.
Remedy: Inspect the vacuum pump motor, the 200V main power source, and their connections.
------------------------------
Code: 12050181
Display: Shutter 1 Alarm
Upper limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the upper-limit sensor for the shutter of the D1-axis.
Remedy: Check the upper-limit sensor for the shutter of the D1-axis.
------------------------------
第 494 页
Code: 12050182
Display: Shutter 1 Alarm
Lower limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the lower-limit sensor for the shutter of the D1-axis.
Remedy: Check the lower-limit sensor for the shutter of the D1-axis.
------------------------------
Code: 12050183
Display: Shutter 2 Alarm
Upper limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the upper-limit sensor for the shutter of the D2-axis.
Remedy: Check the upper-limit sensor for the shutter of the D2-axis.
------------------------------
Code: 12050184
Display: Shutter 2 Alarm
Lower limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the lower-limit sensor for the shutter of the D2-axis.
Remedy: Check the lower-limit sensor for the shutter of the D2-axis.
------------------------------
Code: 12050188
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper UP sensor (X080) failed to switch on.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 12050189
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper DOWN sensor (X080) failed to switch off.
Remedy: Check the D1-table stopper DOWN sensor.
------------------------------
Code: 1205018A
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper DOWN sensor (X080) failed to switch on.
Remedy: Check the D1-table stopper DOWN sensor.
------------------------------
Code: 1205018B
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper UP sensor (X080) failed to switch off.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 1205018C
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error was detected at the D1-table stopper UP/DOWN sensors. The UP sensor (X080) and
the DOWN sensor (X081) are both on.
Remedy: Check the sensors.
第 495 页
------------------------------
Code: 1205018D
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper UP sensor (X096) failed to switch on.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 1205018E
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper DOWN sensor (X097) failed to switch off.
Remedy: Check the D2-table stopper DOWN sensor.
------------------------------
Code: 1205018F
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper DOWN sensor (X097) failed to switch on.
Remedy: Check the D2-table stopper DOWN sensor.
------------------------------
Code: 12050190
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper UP sensor (X096) failed to switch off.
Remedy: Check the D2-table stopper UP sensor.
------------------------------
Code: 12050191
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error was detected at the D2-table stopper UP/DOWN sensors. The UP sensor (X096) and
the DOWN sensor (X097) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050192
Display: D1 pallet UP error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1 pallet UP sensor (X08C) is on.
Remedy: Lower the D1 pallet.
------------------------------
Code: 12050193
Display: D1 pallet sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D1 pallet UP sensor. The D1 pallet UP sensor (X08C) and DOWN
sensor (X07F) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050194
Display: D2 pallet UP error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1 pallet UP sensor (X0A2) is on.
Remedy: Lower the D2 pallet.
------------------------------