Operation mode (Operation Error handling mode (Recovery) Recovery timing (Recovery) Block skip mark reading mode (Operation) Nozzle station (Nozzle Settings) Nozzle alllocation (Nozzle Settings) -------------------------…
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the machine configuration data file. All machine data
items have been reset to their default values.
Remedy: Select the [Configuration] command to edit the required items and use the [System Backup]
command to save the changes.
Alternatively, download an uncorrupted configuration data file and load it using the [Restore
System] command.
------------------------------
Code: 11100307
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range.
Remedy: Select the [Configuration] command to edit the required items.
Alternatively, download an uncorrupted configuration data file and load it using the [Restore
System] command.
------------------------------
Code: 11100308
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the machine configuration data
file.
Remedy: Select the [Configuration] command to edit the required items and use the [System Backup]
command to save the changes.
------------------------------
Code: 11100309
Display: MCTYPE error
Used by: NP2,QP3
Cause: The MCTYPE settings in calibration data are not suitable for this machine. All values returned to
default settings.
Remedy: Use the [Calibration] commands to reset calibration data. Alternatively, use the [Restore System]
command at the [Data Manager] screen to restore calibration data.
------------------------------
Code: 1110030A
Display: Insufficient data!
Used by: NP2,QP3
Cause: The displayed parameter item does not exist in the machine function settings file.
Remedy: Use the management command to restore the machine function settings file.
------------------------------
Code: 1110030B
Display: The parts camera type is incorrect
Used by: QP3
Cause: The parts camera type specified in the machine settings cannot be used on this machine.
Remedy: Check the part camera type specified in the machine settings.
------------------------------
Code: 11100401
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the machine status file. All machine status settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
第 236 页
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100402
Display: File save error!
Used by: NP2,QP3
Cause: Failed to write the machine status file to the hard disk.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100403
Display: File creation error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the machine status file. All machine status settings have
been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100404
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision file for the system is too old. All system settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100405
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision file for the machine status file is too new. All machine status settings have been
cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
第 237 页
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100406
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the machine status file. All machine status settings have
been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100407
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range. All machine status
settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100408
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the machine status file. All system
settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
第 238 页