FUJI错误代码查询.pdf - 第904页

Cause: The Syntax error occurred in the stepping motor controller. Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot, because the controller board could be damaged…

100%1 / 5282
Cause: Association was suspended because a feeder was removed.
Remedy: Reset the feeder on the device (PFU etc.).
------------------------------
Code: 12202010
Display: Parameter error.
Used by:
Cause: DxShell was set an invalid parameter.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202011
Display: No data.
Used by:
Cause: It was not possible to get data from DxShell.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202020
Display: Device communication error.
Used by:
Cause: The time-out interval elapsed, and the response data did not receive.
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12202021
Display: Device communication error.
Used by:
Cause: It was not possible to do writing in Device communication port
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12203001
Display: Invalid Command
Used by:
Cause: The stepping motor controller detected an invalid command.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203002
Display: Axis error
Used by:
Cause: The stepping motor controller detected a command to a axis
that is unused.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203003
Display: Syntax error
Used by:
第 903 页
Cause: The Syntax error occurred in the stepping motor controller.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203004
Display: Link error
Used by:
Cause: The link communication error occurred in the stepping motor controller.
Remedy: The cause is possible that the noise from outside or
that the power has been turned on and off during communication.
Reboot the machine.
------------------------------
Code: 12203005
Display: Check sum error
Used by:
Cause: The Check sum error occurred in the stepping motor controller.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203006
Display: Break signal error
Used by:
Cause: The stepping motor shell received the break signal.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 1220300A
Display: Multiple open
Used by:
Cause: The Stepping-Motor-Shell been already opened.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300B
Display: Port error
Used by:
Cause: The Stepping-Motor-Shell is not still opend.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300C
Display: Initialize error
Used by:
Cause: Initialization of the shell did not end within a prescribed time.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300D
Display: Timeout
Used by:
Cause: There is no response from a controller after transmitting a command.
第 904 页
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300E
Display: Axis error
Used by:
Cause: The axis been already opened.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300F
Display: Axis error
Used by:
Cause: The axis is not still opened.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 12203010
Display: Axis error
Used by:
Cause: The axis is not still initialize.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 12203011
Display: DLL open error
Used by:
Cause: Failed to open DLL.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 12203012
Display: COM port error
Used by:
Cause: Failed to open COM port.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 12203013
Display: COM port error
Used by:
Cause: Failed to initialize COM port.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 12203014
Display: COM port error
Used by:
Cause: Failed to a setting of time-out interval of COM port.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.