FUJI错误代码查询.pdf - 第573页

Code: 1205501A Display: Pressure measurement file error. Used by: NP-2, QP-3 Cause: Cannot read the pressure measurement file. Remedy: Inspect the condition of the hard disk. It may be full or damaged. ------------------…

100%1 / 5282
Remedy: Check that a back-up pin is not contacting parts on the lower surface of the board. Unload the
board if parts are being contacted, otherwise resumu operation after adjusting the position of the board.
------------------------------
Code: 12055012
Display: Vision processing has been aborted.
Used by: NP2,QP3
Cause: The execution of vision processing has been aborted.
Remedy: Restart the machine. Contact Fuji if this problem occurs even after the machine is restarted.
------------------------------
Code: 12055013
Display: Data error!
Used by: NP2,QP3
Cause: Internal data error!
Remedy: Restart the machine.
------------------------------
Code: 12055014
Display: Pre-allocated sequence error!
Used by: NP2,QP3
Cause: Pre-allocated sequence error!
Remedy: Check the production program, unload the PCB and restart the machine.
------------------------------
Code: 12055015
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot create pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055016
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot open pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055017
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot close pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055018
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot change the name of the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055019
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot write to the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
第 572 页
Code: 1205501A
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot read the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 1205501B
Display: 没有进行周期自动补正的有效的吸嘴。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 没有进行周期自动补正的有效的吸嘴。
Remedy: 请安装能够进行周期自动补正的吸嘴。
------------------------------
Code: 12055026
Display: 周期自动补正超过了补正容许范围。
请用测定回转中心指令进行测定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 周期自动补正值超过了补正公差值。
Remedy: 请用测定回转中心指令进行测定。
------------------------------
Code: 12055027
Display: Double placement error
Used by: QP3
Cause: A sequence that has already been completed has been specified. Parts may be placed on top of
one another.
Remedy: Acquire a trace and unload the panel from the machine.
------------------------------
Code: 12055028
Display: 周期自动补正的测定结果超过极限。
Used by: XP142,XP242
Cause: 周期自动补正的测定结果超过极限。
Remedy: 请重新检查极限的下限值和上限值。
------------------------------
Code: 12056001
Display: "Nozzle type alarm" (CP4), "ST17 nozzle type detection error: HEAD?"
(CP6)
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: When this error occurs on a CP4, none of the nozzle type check sensors has turned on.On a CP6,
a nozzle type check (ST17) indicated a nozzle type other than 1 through 6.
Remedy: On a CP4, adjust ST10 and ST11 so that the sensors can detect the nozzle type. If this error
seems to occur with no specific nozzle on a CP6, check the adjustment of the nozzle type detection sensor.
If it tends to occur with a specific nozzle, inspect the nozzle detection locations for the specified head.
------------------------------
Code: 12056002
Display: "Nozzle change error"
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The results of a nozzle change check (ST11) indicate a different nozzle type than that remembered
by the machine.On the CP6, this error is reported when a nozzle type check (ST19) performed after a
nozzle change (ST18) indicates a nozzle type other than 1 through 6. This error may also occur if the
nozzle has been changed to a type other than the targeted type.
Remedy: Check the holder, or adjust the nozzle type check sensor.If this error seems to occur with no
specific nozzles on a CP6, check the adjustment of the nozzle type detection sensor. If it tends to occur
第 573 页
with a specific nozzle, inspect the nozzle detection locations for the specified head.
------------------------------
Code: 12056003
Display: 侧夹紧传感器逻辑异常
Used by: GSP5,GP551,GP6,GPX,GPX-C
Cause: 侧松开传感器或侧夹紧正常传感器的输入在逻辑上变得不正常。(GSP5) 即使电路板松开,侧夹紧落空确认传
感器也没有ON。 (GPX)
Remedy: 请进行侧松开传感器或侧夹紧正常传感器的调整/更换,使之变成以下的逻辑。
电路板松开时 正常夹紧时 夹紧失败时
松开 ○ × ×
正常夹紧 ○ ○ ×(GSP5) 1.请确认是否有妨碍了侧夹紧动作的落下电路板等的
存在。
2.什么也没有时,需要进行电路板侧夹紧落空确认传感器(GPX:RX006,GPX-C:IN10)的调整。(请与本公司的
Support联系)(GPX,GPX-C)
<img src="$LKEY_ERRIMG_MC$/EI0007.bmp">
------------------------------
Code: 12056004
Display: Sldr unit Position Error
Used by: GSP5
Cause: The position of the automatic paste dispenser is unacceptable.
Remedy: The adjustment of the sensor is probably incorrect. Adjust the sensor so that it corresponds
with the position of the automatic paste dispenser.
------------------------------
Code: 12056005
Display: Wrong Sqg Pres Data
Used by: GSP5
Cause: This error occurs only when the print pressure feedback option is in use.When measuring the
print pressure, a Low signal which was higher than the Hi signal was detected. This indicates that there
is an error in the Hi/Low logic specified in the print comparator. Furthermore, the low signal (X072 SQG
PRES LO) may be short circuited to GB.
Remedy: The print pressure input logic must be specified in the following manner: Hi is greater than
Low.Check that the high/low wiring is correct (GSP5). The pressure change/time gradient is too
steep.Adjust the Pressure/Time control item in Proper data to give a less steep gradient.
------------------------------
Code: 12056006
Display: M/C err Sqg Pres Range Over
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: This error occurs only when print pressure feedback is being used. Although the control pressure
dropped below 0% or exceeded 100% when print pressure feedback was being used, the print pressure did
not automatically return to the specified range.
Remedy: The print pressure input logic must be specified in the following manner: Hi is greater than
Low.The printing height may be too low or there may be something between the screen and the board
(GSP5).
------------------------------
Code: 12056007
Display: Error : PPC origin positon sensor
Used by: IP3
Cause: During calibration the reference position check sensor did not come on when parts were being
placed, or the sensor was already on when operation began.
Remedy: At the I/O map check that the reference position check sensor turns on and off
correctly.Furthermore, check the sensor and the nozzle if the sensor is on even when the nozzle is not
第 574 页