FUJI错误代码查询.pdf - 第126页

Remedy: When using the MCS, set Pcb_x in the production program. When using F4G, check the value of General PCB Data X. Refer to the board length in the FQP1. In order to position the board in the pallet, the correct boa…

100%1 / 5282
Display: 与编码相同
Used by: GSP5,GP2,GP3,GP551,GP6,GPX,NXTP
Cause: 焊锡供应计数在范围之外。
Remedy: 请确认生产程序的Solder_supply_counter(在GP6中使用了F4G时,确认
Solder_supply_interval)。范围是0~65000[块](如果是GSP5时,范围是
0~60000[块])。 请确认在FujiFlexa上设定的焊锡供应计数。范围是0~9999[块]。
(GPX,NXTP)
------------------------------
Code: 1101E022
Display:
Used by: GSP5
Cause: The solder viscosity is out of range.
Remedy: Check solder_viscsty in the production program. The range is 1 to 60 [*10 Pa.s]
------------------------------
Code: 1101E023
Display:
Used by: GSP5
Cause: The solder supply one-way count is out of range.
Remedy: Check solder_supply_times in the production program. The range is 1 to 10.
------------------------------
Code: 1101E024
Display: 与编码相同
Used by: GSP5,GP551,GP6,GPX,NXTP
Cause: 手动清洁计数器在范围之外。
Remedy: 请确认生产程序的manual_cleaning_counter(在GP6中使用了F4G时,确认
manual_cleaning_interval)。 范围是0~65000[块]。 请确认在
FujiFlexa上设定的手动清洁计数。范围为0~9999[块]。(GPX,NXTP)
------------------------------
Code: 1101E025
Display: 与编码相同
Used by: GSP5,GPX,NXTP
Cause: 清洁速度超出范围。
Remedy: 请确认生产程序的cleaning_speed。
范围:从10到200[mm/sec]
请确认在FujiFlexa设定的清洁速度。
范围:从1到300[mm/sec](GPX)
范围:从10到300[mm/sec](NXTP)
------------------------------
Code: 1101E026
Display: 与编码相同
Used by: GSP5,GP2,GP3,GP551,GP6,GPX,NXTP
Cause: 虽然存在不使用侧夹紧的生产(65.Side_clamp为OFF),25.Vacuum_flag不是
ALL_ON,68.Use_vacuum也没有被指定。(GSP5)
侧夹紧OFF时,请将电路板真空ON。(GPX,NXTP)
Remedy: 请检查生产程序的65.Side_Clamp,25.Vacuum_flag,68.Use_vacuum。请确认
FujiFlexa上的侧夹紧设定和电路板真空设定。(GPX,NXTP)
------------------------------
Code: 1101E027
Display: 1101E027
Used by: QP132
Cause: The board length is not specified (FQP1).
第 125 页
Remedy: When using the MCS, set Pcb_x in the production program. When using F4G, check the value of
General PCB Data X. Refer to the board length in the FQP1. In order to position the board in the pallet,
the correct board length (tolerance within +-0.5 mm) must be specified.
------------------------------
Code: 1101E028
Display: 1101E028
Used by: QP132
Cause: The board width is not specified (FQP1).
Remedy: When using the MCS, set Pcb_y in the production program. When using F4G, check the value of
General PCB Data Y. If a board with a different width is detected on the FQP1 it is unloaded. For this
reason the board width must be entered. Board width is judged to be different if the current board width
differs from the previous board width by more than +-0.5 mm.
------------------------------
Code: 1101E029
Display: 1101E029
Used by: QP132
Cause: The board thickness is not specified (FQP1).
Remedy: When using F4G, check the value of General PCB Data Thickness in the production program.
On the FQP1, the reference point for the pickup nozzles is taken as the lower surface of the board.
Therefore, the board thickness must be input.
------------------------------
Code: 1101E02A
Display: Same as code
Used by: QP132
Cause: The rotation angle specified for board setup in the program header is outside the valid range.
This error occurs when the program is checked upon transmission.
Remedy: Set the rotation angle for board setup in the program header to 0 to load the board without
rotation, or 3 to load with rotation.
------------------------------
Code: 1101E02B
Display: Same as code
Used by: QP132
Cause: The multiple board loading flag in the program header is outside the valid range. This error
occurs when the program is checked upon transmission.
Remedy: Set the multiple board loading flag in the program header to 0 or 1 when loading a single board,
or to 2 for tandem loading.
------------------------------
Code: 1101E02C
Display: Same as code
Used by: QP132
Cause: The number of blocks per board has not been set even though the multiple board loading flag in
the program header indicates that tandem loading is to be performed. This error occurs when the
program is checked upon transmission.
Remedy: Set the number of blocks per board when the multiple board loading flag in the program header
indicates that tandem loading is to be performed.
------------------------------
Code: 1101E02D
Display: Same as code
Used by: QP132
Cause: The value of the indexing type parameter in the program header is outside the valid range. This
error occurs when the program is checked upon transmission.
第 126 页
Remedy: Set the indexing type in the program header to one of the following values: 0, 2, 3, 4, or 5. These
settings indicate 7-inch indexing, 5-2 indexing, 4-3 indexing, 3-4 indexing, and 2-5 indexing, respectively.
------------------------------
Code: 1101E02E
Display: Same as code
Used by: QP132
Cause: Different indexing types are specified for programs having the same family name.
Remedy: Change the family name, or set the indexing types to the same value.
------------------------------
Code: 1101E02F
Display: Same as code
Used by: QP132
Cause: Unexecutable sequences have occurred because the indexing type in the program header has
been set to 7-inch single indexing. This error occurs when the program is checked upon transmission.
Remedy: Check the mounting coordinates in the sequence data. If the coordinates are correct, set the
indexing type in the program header to a value other than 0.
------------------------------
Code: 1101E030
Display: Same as code
Used by: QP132
Cause: A family name has not been set in the program header. This error occurs when the program is
checked upon transmission.
Remedy: Set a family name in the program header.
------------------------------
Code: 1101E031
Display: Same as Code.
Used by: QP132
Cause: The value set for the loading distance position for tandem loading ("PCB distance") has been set to
a positive value.
Remedy: Set this item to a negative value.
------------------------------
Code: 1101E032
Display: 与编码相同
Used by: GP551,GP6,GPX,NXTP
Cause: 特殊清洁计数器超出范围。
Remedy: 请确认生产程序的Special_cleaning_interval。
范围:0~65000[块]
请确认FujiFlexa上设定的特殊自动清洁计数器。
范围:0~9999[块](GPX,NXTP)
自动清洁为0块时,不能对特殊清洁进行1块以上的设定(GPX,NXTP)。
------------------------------
Code: 1101E033
Display: Same as code
Used by: GP2,GP3,GP551,GP6
Cause: The pressure measurement interval setting is outside the valid range.
Remedy: Make sure that the "Press_meas_interval" parameter in the production program is set to a value
from 0 to 65000 [boards].
------------------------------
Code: 1101E034
Display: Same as code
Used by: GP551,GP6
第 127 页