FUJI错误代码查询.pdf - 第1137页
Display: Out-lifter panel conveyance error. Used by: CP-732E, CP-742ME, CP-742E Cause: The out-lifter panel sensor 1 (X0C7) failed to switch on even though 1 panel was loaded from the out-carrier. Remedy: Check the panel…
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensors 1 and 2 (X0CC, X0CD) failed to switch on even though 2 panel s
were loaded from the XY-table. In systems with a panel present memory, the panel present/absent status
on the out-carrier was checked, but the out-carrier 1 panel sensor and the out-carrier 2 panel sensor
could not verify the presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the out-carrier, use the out-
carrier unclamp command to open the out-carrier. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 1504041F
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensor 1 (X0CC) failed to switch on even though 1 panel was loaded from
the XY-table. In systems with a panel present memory, the panel present/absent status on the out-carrier
was checked, but the out-carrier 1 panel sensor could not verify the presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the out-carrier, use the out-
carrier unclamp command to open the out-carrier. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040420
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensor failed to switch on even though a panel was conveyed from the XY-
table to the out-carrier.
Remedy: Check to see if the panel has been conveyed properly to the our-carrier. If the error persists
even though the panel conveyance has occurred properly, adjust the sensor mounting position.
------------------------------
Code: 15040421
Display: Out-lifter logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP and DOWN limit sensors are both off.
Remedy: Move the out-lifter to either the UP or DOWN limit position, and if the error still occurs, readjust
the sensor mounting position. If the sensor still fails to switch on even after adjusting its mounting
position, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040422
Display: Out-lifter logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP and DOWN limit sensors are both on.
Remedy: Readjust the sensor mounting position. If the sensor still fails to switch off even after adjusting
its mounting position, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040423
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter panel sensors 1 and 2 (X0C7, X0C9) failed to switch on even though 2 panel s were
loaded from the out-carrier.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040424
第 1136 页
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter panel sensor 1 (X0C7) failed to switch on even though 1 panel was loaded from the
out-carrier.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040425
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The interval between the first and second panel s is incorrect. Alternatively, the interval sensor
(X0CA) is mounted in the wrong position.
Remedy: If this error occurs when both the interval setting data and the sensor mounting position are
correct, check to see if the interval sensor is operating correctly. This sensor should be on when no panel
is detected.
------------------------------
Code: 15040426
Display: Panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Error occurred during panel conveyance at the out-conveyor. After panel conveyance was
started, the panel failed to arrive at the out-conveyor's panel arrival sensor (X0CB) position within the
prescribed period of time.
Remedy: Check to see if the panel is stuck. If so, adjust the conveyor width to accommodate the panel .
If this error occurs even though the panel has in fact arrived, check the sensor operation.
------------------------------
Code: 15040427
Display: Panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Loader idling cannot be performed because a panel is present in the machine.
Remedy: Unload all panel s from the machine.
------------------------------
Code: 15040428
Display: 次工程电路板搬运异常
Used by: CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP
Cause: 在向下工序搬运电路板中发生了异常。
虽然向下工序送出了送出侧的电路板,但是在下工序中无法正常地搬运电路板,在规定时间(15秒)内来自下工序的
电路板要求信号没有OFF。
Remedy: 请调整下工序的搬运轨道宽度,以保证电路板能够传送。
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040428.PNG">
------------------------------
Code: 15040429
Display: Out-conveyor mid-stopper error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-conveyor mid-stopper ON limit sensor failed to switch on. Although the out-conveyor
mid-stopper was switched off, the OFF limit sensor failed to switch on within the prescribed period of time
(3 secs.).
Remedy: If this error occurs even though both the stopper ON and OFF limit sensors switch on within the
prescribed period of time, with the stopper operating correctly, check the operation of the sensors (X0C4,
X0C5).
------------------------------
第 1137 页
Code: 1504042A
Display: Out-conveyor panel set error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A panel conveyance problem on the out-conveyor is preventing proper panel conveyance. During
single-board production, 2 boards were unloaded from the out-carrier. Alternatively, during double-board
production, there was no interval between the panel s unloaded from the out-carrier (Out 1, Out 2 panel
interval sensors are off).
Remedy: Verify that the number of panel s on the out-lifter matches the number of panel s designated by
the current production mode (single or double board production). If the panel s are being conveyed
properly, verify that the sensors (X0C7, X0C9, X0CA) are operating properly. This error may also occur if
there is a mid-stopper problem which results in the panel s not stopping at the stopper position. The
panel interval sensor should be on when a panel is absent, and off when a panel is present.
------------------------------
Code: 1504042B
Display: Out-conveyor panel sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Within 1 second after the out-carrier retract command was executed in order to unload the out-
carrier panel to the out-lifter, a panel was detected on the out-lifter by a sensor.
Remedy: Check to see if the sensors (X0C7, X0C9, X0CA) are operating properly. The panel interval
sensor should be on when a panel is absent, and off when a panel is present.
------------------------------
Code: 1504042C
Display: Out-conveyor panel sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier 1 panel sensor or the out-carrier 2 panel sensor switched on when panel
unloading from the XY-table to the out-carrier was attempted. The out-carrier 1 panel sensor or the out-
carrier 2 panel sensor remained on for 0.5 seconds when the XY-table was at its DOWN limit or loading
position with the out-carrier open at its advance limit position.
Remedy: Check to see if the sensors (X0CC, X0CD) are operating properly.
------------------------------
Code: 1504042D
Display: Out-lifter cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP limit sensor failed to switch on. The out-lifter was lowered but the DOWN limit
sensor failed to switch on within the prescribed time period (3 secs.).
Remedy: Check to see if the out-lifter is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0D0, X0D1) are operating properly.
------------------------------
Code: 1504042E
Display: Out-carrier cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter advance limit sensor failed to switch on. The out-carrier was retracted but the
retract limit sensor failed to switch on within the prescribed time period (8 secs.).
Remedy: Check to see if the out-carrier is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0CE, X0CF) are operating properly.
------------------------------
Code: 1504042F
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: At the out-carrier panel check, the out-carrier 1 panel sensor turned on.
Remedy: Check the panel conveyance condition. If this error occurs even though the panel s are being
第 1138 页