Cause: Nozzle settings for this machine are not included in the nozzle settings file. All nozzle settings have been cleared. Remedy: Download a compatible nozzle settings file, reboot the machine and load the settings us…
the [Update] command.
------------------------------
Code: 11100701
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the nozzle settings file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100702
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle settings file.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100703
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle settings file. All nozzle settings have been
cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100704
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle data items displayed in the parameter section are outside the prescribed range. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100705
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle settings file. All nozzle
settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100706
Display: Nozzle name inconsistency error!
Used by: NP2,QP3
Cause: The nozzle spec. names displayed in the parameter section are not listed in the nozzle
specifications file.
Remedy: Download a correct nozzle settings file, reboot the machine and load the settings using the
[Update] command.
------------------------------
Code: 11100707
Display: Insufficient data!
Used by: NP2,QP3
第 241 页
Cause: Nozzle settings for this machine are not included in the nozzle settings file. All nozzle settings
have been cleared.
Remedy: Download a compatible nozzle settings file, reboot the machine and load the settings using the
[Update] command.
------------------------------
Code: 11100801
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle station settings file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100802
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle station settings file.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100803
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle station settings file. All nozzle settings have
been cleared.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100804
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle station settings file. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100805
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle station settings for this machine are not included in the nozzle station settings file. All
nozzle settings have been cleared.
Remedy: Download a compatible nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100901
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle station specifications file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the
settings using the [Update] command.
------------------------------
Code: 11100902
第 242 页
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle station specifications file.
Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the
settings using the [Update] command.
------------------------------
Code: 11100903
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle station data items displayed in the parameter section are outside the prescribed range.
All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100904
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle station specifications
file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100905
Display: Nozzle station inconsistency error!
Used by: NP2,QP3
Cause: The nozzle station spec. names displayed in the parameter section are listed in the nozzle station
settings file, but are missing from the nozzle station specifications file.
Remedy: Download compatible nozzle station settings and specification files, reboot the machine and load
the settings using the [Update] command.
------------------------------
Code: 11100906
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: CCIMF file format error in nest specifications file. All nozzle data has been cleared from memory.
Remedy: Download a normal nest specifications file, then start up the machine. Use the nozzle memory
change command to re-register the nozzles.
------------------------------
Code: 11100907
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle station specifications for this machine are not included in the nozzle station specification
file. All nozzle settings have been cleared.
Remedy: Download a compatible nozzle station specification file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100A01
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open camera definition file. Cannot use the camera(s).
Remedy: Download or reinstall an uncorrupted camera definition file and restart the machine.
------------------------------