FUJI错误代码查询.pdf - 第1154页

Code: 15040783 Display: LD TRANS BACKWARD TUP Loader error: 15040783 Used by: QP132 Cause: The pallet pusher that moves a pallet from the return-conveyor to the pallet loader did not finish retracting in the given time. …

100%1 / 5282
Code: 15040774
Display: LD MX MOVE TUP
Loader error: 15040774
Used by: QP132
Cause: The MX-axis movement of the loading side manipulator was not completed within the set amount
of time.
Remedy: A servo alarm has occurred. Rectify the servo alarm status and then restart.
------------------------------
Code: 15040776
Display: LD MANI RISE FAIL
Loader error: 15040776
Used by: QP132
Cause: The entry board transport upper-limit sensor went off during movement of the loading side
manipulator.
Remedy: Make sure that the air pressure used to raise the board, which has been transported in, has not
fallen. Check the operation of the entry board transport upper-limit sensor.
------------------------------
Code: 15040778
Display: IN_CVR PCB STEY FAIL
Loader error: 15040778
Used by: QP132
Cause: A board remained on the in-conveyor when the loading side manipulator completed the operation
of grabbing a board from the in-conveyor.
Remedy: Check the operation of the in-conveyor board-arrival-check sensor. The in-conveyor board-
arrival-check sensor should be in the off status when the loading side manipulator has finished grabbing
the board from the in-conveyor and raising it.
------------------------------
Code: 15040780
Display: LD 10-SHIFT FORWARD TUP
Loader error: 15040780
Used by: QP132
Cause: The in-conveyor side's pallet 10 mm shift to the right operation did not finish in the given time.
Remedy: Check the loading pallet's right shift position (X054: P.IN PLT RSFT) operation using I/O
commands and adjust if necessary.
------------------------------
Code: 15040781
Display: LD 10-SHIFT BACKWARD TUP
Loader error: 15040781
Used by: QP132
Cause: The in-conveyor side's pallet 10 mm shift to the left operation did not finish in the given time.
Remedy: Check the loading pallet's left shift position (X055: P.IN PLT LSFT) operation using I/O
commands and adjust if necessary.
------------------------------
Code: 15040782
Display: LD TRANS FORWARD TUP
Loader error: 15040782
Used by: QP132
Cause: The pallet pusher that moves a pallet from the return-conveyor to the pallet loader did not finish
extending in the given time.
Remedy: Check the X04A: RCV PUSH FWEND operation using I/O commands and adjust if necessary.
------------------------------
第 1153 页
Code: 15040783
Display: LD TRANS BACKWARD TUP
Loader error: 15040783
Used by: QP132
Cause: The pallet pusher that moves a pallet from the return-conveyor to the pallet loader did not finish
retracting in the given time.
Remedy: Check the X04B: RCV PUSH BWEND operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040784
Display: RCV-LD CHANGE TUP
Loader error: 15040784
Used by: QP132
Cause: The loader's pallet sensor did not come on when the pallet was moved from the return-conveyor
to the pallet loader.
Remedy: Check the X050: P.IN ARRV CK operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040801
Display: PO POSITIONING ERROR
Loader error: 15040801
Used by: QP132
Cause: There is a difference of at least 10 pulses between the movement command position and the
current position of the PO-axis.
Remedy: Make sure there is no load on the PO-axis, and restart.
------------------------------
Code: 15040856
Display: UNLD PCB CLAMP TUP
Loader error: 15040856
Used by: QP132
Cause: The unloaded pallet closed check (X064: P.OUT PLT CLS) did not come on in the given time (QP-
132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040857
Display: UNLD PCB UNCLAMP TUP
Loader error: 15040857
Used by: QP132
Cause: The unloaded pallet open check (X063: P.OUT PLT OPN) did not come on in the given time (QP-
132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040860
Display: UNLD BACKWARD TUP
Loader error: 15040860
Used by: QP132
Cause: The pallet unloaded cylinder retract sensor (X062: P.OUT BWD) did not come on in the given time
(QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040861
Display: UNLD FORWARD TUP
Loader error: 15040861
第 1154 页
Used by: QP132
Cause: The pallet unload cylinder extend sensor (X061: P.OUT FWEND) did not come on in the given
time (QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040862
Display: UNLD PLT CLAMP TUP
Loader error: 15040862
Used by: QP132
Cause: The unloaded pallet unclamp check sensor (X072: P OUT PLT UCLP) did not turn off in the given
time (QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040863
Display: UNLD PLT UNCLAMP TUP
Loader error: 15040863
Used by: QP132
Cause: The OUT pallet unclamp limit check sensor (X05C:P OUT PLT UCLP) did not turn on within the
specified time.
Remedy: Use I/O commands to make sure that the sensor is functioning normally, and adjust it if
necessary.
------------------------------
Code: 15040866
Display: UNLD MANI HOOK OPEN TUP
Loader error: 15040866
Used by: QP132
Cause: The out-conveyor manipulator claw has not opened in the given time.
Remedy: Check the PCB unload claw (X07B: PCB UL HOOK OP) operation using I/O commands and
adjust if necessary.
------------------------------
Code: 15040867
Display: UNLD MANI HOOK CLOSE TUP
Loader error: 15040867
Used by: QP132
Cause: The open and close operation of the manipulator hook on the unloading side was not completed
within the set amount of time.
Remedy: Check the open and close operation of the unloading side manipulator hook and the operation of
the open/close check sensors.
------------------------------
Code: 15040868
Display: UNLD MANI RISE TUP
Loader error: 15040868
Used by: QP132
Cause: The out-conveyor manipulator claw has not been raised in the given time.
Remedy: Check the PCB unload claw (X07A: PCB UL UPCHK) operation using I/O commands and adjust
if necessary.
------------------------------
Code: 15040869
Display: UNLD MANI DOWN TUP
Loader error: 15040869
Used by: QP132
第 1155 页