Remedy: Check that the screen Y transport can move properly. Check that the retract and advance limit sensors are inputting correctly. ------------------------------ Code: 12020404 Display: Used by: Cause: The Y chuck co…

100%1 / 5282
Display:
Used by: GSP5
Cause: The viscosity setting is out of range.
Remedy: Check solder_viscsty in the production program. The range is 1 to 60 [*10 Pa.s].
------------------------------
Code: 12020307
Display:
Used by: GSP5
Cause: Even after mixing was done for a certain time (1 hour 30 minutes) the viscosity did not go below
the viscosity specified.
Remedy: The viscosity specification is probably too high. Chenge the setting.
------------------------------
Code: 12020308
Display:
Used by: GSP5
Cause: There is no solder.
Remedy: Add solder. If this error occurs even if there is solder left, this means that the viscosity level is
too high, the solder was just transferred from the fridge or you are using high-viscosity (2500P) solder.
Check each of these points and make appropriate adjustments.
------------------------------
Code: 12020309
Display:
Used by: GSP5
Cause: The garage has not been set in the housing.
Remedy: The housing has been removed, or the sensor is not working properly. Check these points and
make adjustments.
------------------------------
Code: 12020320
Display:
Used by: GSP5
Cause: Communication was not possible with the solder supply machine.
Remedy: Check that the solder supply machine is turned on, and that the communication cable is
correctly connected.
------------------------------
Code: 12020401
Display:
Used by:
Cause: The elevator could not ascend or descend in the specified time.
Remedy: Check the load on the stocker elevator being raised or lowered.
------------------------------
Code: 12020402
Display:
Used by:
Cause: The stocker could not be clamped within the specified time.
Remedy: Check that the stocker is set in the correct position. Check that the stocker clamp cylinder is
moving properly.
------------------------------
Code: 12020403
Display:
Used by:
Cause: The Y transport could not advance or retract in the specified time.
第 293 页
Remedy: Check that the screen Y transport can move properly. Check that the retract and advance limit
sensors are inputting correctly.
------------------------------
Code: 12020404
Display:
Used by:
Cause: The Y chuck could not open or close in the specified time.
Remedy: Check that the screen Y transport chuck can open/close correctly. Check that the sensors are
operating correctly.
------------------------------
Code: 12020410
Display:
Used by:
Cause: If the machine is barcode-compatible, screens up to #10 were used properly. If the machine is
barcode-compatible, a screen with the name set in the program does not exist in the stocker.
Remedy:
------------------------------
Code: 12020411
Display:
Used by:
Cause: Even though there is a screen in the backside cleaning position, the screen supply command did
not occur.
Remedy: If the screen is being supplied from the stocker, remove the screen from the backside cleaning
position.
------------------------------
Code: 12020412
Display:
Used by:
Cause: The screen is not in the proper position.
Remedy: Check that there is a screen.
------------------------------
Code: 12020413
Display:
Used by:
Cause: The elevator is in the overtravel position.
Remedy: Inch the elevator away from the overtravel sensor.
------------------------------
Code: 12020414
Display:
Used by:
Cause: The elevator is in the overtravel position.
Remedy: Inch the elevator away from the overtravel sensor.
------------------------------
Code: 12020415
Display:
Used by:
Cause: The screen has left the stocker so the elevator cannot move.
Remedy: Return the screen to its proper position in the elevator.
------------------------------
Code: 12020416
Display:
第 294 页
Used by:
Cause: The stocker is not set so the screen cannot be supplied or received.
Remedy: Set the stocker.
------------------------------
Code: 12020417
Display:
Used by:
Cause: There is a screen in the receiving position so screens cannot be received.
Remedy: Make a space in the stocker so that screens can be received.
------------------------------
Code: 12020420
Display:
Used by:
Cause: The barcode cannot be read.
Remedy: Check the condition of the barcode on the screen.
------------------------------
Code: 12020421
Display:
Used by:
Cause: This error code was caused by the barcode reader.
Remedy: Consult the barcode reader operation manual.
------------------------------
Code: 12020422
Display:
Used by:
Cause: An unknown command was sent to the stocker.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji.
------------------------------
Code: 12020423
Display:
Used by:
Cause: The stocker is in local mode.
Remedy: Put the stocker into online mode.
------------------------------
Code: 12020424
Display:
Used by:
Cause: This error code was caused by the servo amp.
Remedy: Check the stocker elevator servo amp.
------------------------------
Code: 12020425
Display:
Used by:
Cause: The elevator axis has not been zero-set.
Remedy: If the stocker has been started, zero-set it.
------------------------------
Code: 12020426
Display:
Used by:
Cause: If the stocker is at #1, the descend command was received. If it was at #10, the ascend command