FUJI错误代码查询.pdf - 第159页
------------------------------ Code: 1102263A Display: Same as code Used by: IP2 Cause: Vision processing cannot be performed when the "nozzle_size_2.Y" parameter in the IP2 Proper data (i.e., the Y value for N…
Display:
Used by: IP2,IP3
Cause: The value set in Proper Data item "Flux_st1_d_no" or "Flux_st2_d_no" is out of range.
Remedy: The valid range for these Proper Data items is 0 to 37 ("0" signifies that it is not used). After
correcting the Proper Data item in question, transmit the production program again.
------------------------------
Code: 11022635
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H2.X" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 2, the nozzle inclination is found using
the "nozzle_size_H2.X" and "nozzle_size_H2.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022636
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H3.X" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 3, the nozzle inclination is found using
the "nozzle_size_H3.X" and "nozzle_size_H3.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022637
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H2.Y" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 2, the nozzle inclination is found using
the "nozzle_size_H2.X" and "nozzle_size_H2.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022638
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H3.Y" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 3, the nozzle inclination is found using
the "nozzle_size_H3.X" and "nozzle_size_H3.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022639
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_1.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 1 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 1 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_1.X" and "nozzle_size_1.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
第 158 页
------------------------------
Code: 1102263A
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_2.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 2 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 2 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_2.X" and "nozzle_size_2.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 1102263B
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_3.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 3 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 3 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_3.X" and "nozzle_size_3.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 1102263C
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_4.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 4 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 4 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_4.X" and "nozzle_size_4.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 1102263D
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_5.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 5 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 5 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_5.X" and "nozzle_size_5.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 1102263E
Display: Same as code
Used by:
Cause: Vision processing cannot be performed when the "nozzle_size_6.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 6 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 6 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_6.X" and "nozzle_size_6.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
第 159 页
Code: 1102263F
Display: None
Used by: IP-3
Cause: Nozzle1_12 settings cannot be used when camera types 12 or 13 are fitted on the head 1 side of
the machine.
Remedy: Clear the settings for Nozzle1_12 and retransmit Proper data.
------------------------------
Code: 11022640
Display: None
Used by: IP-3
Cause: Nozzle2_12 settings cannot be used when camera types 12 or 13 are fitted on the head 2 side of
the machine.
Remedy: Clear the settings for Nozzle2_12 and retransmit Proper data.
------------------------------
Code: 11022701
Display: 11022701
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP2,IP3,QP242,QP201,QP202,Q
P203,QP132
Cause: The Proper data item Command_line_port is out of range (when using HELPS).
Remedy: Check the Proper data item Command_line_port, and retransmit Proper data. This Proper data
item specifies the number of the communication board or LCU connector to which the LMS command line
cable is connected. (the connector number is from 1-4 for machines and from 1-8 for peripherals). Do not
use the same port numbers for different operations. Avoid setting Command_line_port to 1 or 3 for
peripheral machines. Command_line_port is normally set to 2 (this is preset when the machine is
shipped.)
------------------------------
Code: 11022702
Display:
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP2,IP3,QP242,QP201,QP202,Q
P203,QP132
Cause: The Proper data item Reader1_port is set incorrectly.
Remedy: Check the Proper data item in MCS, and re-transmit it to the machine. When
change_over_mode is set to 2, 4 or 25, this must be set. This command determines where the pattern
code reader or the code reader (upper surface) connect to the communication board or the LCU connector
(the connector number is 1~8). Do not use the same port numbers for different operations (i.e. avoid 1, 3
and Command_line_port). Normally, set this to 3 for the machine and 4 for peripherals (this is normally
set when the machine is shipped).
------------------------------
Code: 11022703
Display:
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP3,QP242,QP201,QP202,QP20
3,QP132
Cause: The Proper data item Reader port 1 is the same as Command_line_port.
Remedy: Check the Proper data item in MCS, and re-transmit it to the machine. When
change_over_mode is set to 5 or 25, this must be set. This command determines where the pattern code
reader or the code reader (upper surface) connect to the communication board or the LCU connector (the
connector number is 1~8). Do not use the same port numbers for different operations (i.e. avoid 1, 3,
Reader1_port and Command_line_port). Normally, set this to 3 for the machine and 4
第 160 页