FUJI错误代码查询.pdf - 第1475页
Display: Used by: Cause: Unable to find the lead. Remedy: Check the lead width, part shape and the image taken by vision processing. ------------------------------ Code: 1D17400C Display: Used by: Cause: Unable to find t…
------------------------------
Code: 1D16D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D16E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the orientation at which the part was fed. Check the entries in Part data
and Device data.
------------------------------
Code: 1D16F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D170002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D174001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D174007
Display:
Used by:
Cause: There are 2~4 leads more than set in Part data.
Remedy: Check the setting in Part data.
------------------------------
Code: 1D174009
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D17400A
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D17400B
第 1474 页
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D17400C
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D17400D
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D17400E
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D17400F
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D174010
Display:
Used by:
Cause: The lead width is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D174011
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D174012
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D174013
Display:
Used by:
Cause: The body size is not in the acceptable range.
第 1475 页
Remedy: Check the part shape, check that the part is being picked properly, and check the image taken
by vision processing.
------------------------------
Code: 1D178002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D178100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D178110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D178111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D178112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D178113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D178114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D178115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
第 1476 页