FUJI错误代码查询.pdf - 第4页
Cause: The placing sequence does not exist in the production program (sequence data: N_Data). Remedy: Correct the data in MCS and transmit the program. ------------------------------ Code: 11010111 Display: "Specifi…
Code: 11010108
Display: Program SX+
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +SX direction set in the production program is out of range.
Remedy: Make the +SX value set in the production program (mark read sequence) smaller.
------------------------------
Code: 11010109
Display: Program SX-
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -SX direction set in the production program is out of range.
Remedy: Make the -SX value set in the production program (mark read sequence) larger.
------------------------------
Code: 1101010A
Display: Program SY+
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +SY direction set in the production program is out of range.
Remedy: Make the +SY value set in the production program (mark read sequence) smaller.
------------------------------
Code: 1101010B
Display: Program SY-
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -SY direction set in the production program is out of range.
Remedy: Make the -SY value set in the production program (mark read sequence) larger.
------------------------------
Code: 1101010C
Display: Program S+
Used by: QP242,QP201,QP202,QP203
Cause: The print sequence set in the production program is out of range in the +X direction.
Remedy: Make the +X value set in the print sequence of the production program smaller.
------------------------------
Code: 1101010D
Display: Program S-
Used by: QP242,QP201,QP202,QP203
Cause: The print sequence set in the production program is out of range in the -X direction.
Remedy: Make the -X value set in the print sequence of the production program larger.
------------------------------
Code: 1101010E
Display: Program 0001
Used by: GL2,QP242,QP201,QP202,QP203
Cause: The head number has not been entered in sequence data.
Remedy: Check the "H" heading in the production program.
------------------------------
Code: 1101010F
Display: Program 0020
Used by: GL2,GL541,QP242,QP201,QP202,QP203
Cause: G data is not entered in the application sequence.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010110
Display:
Used by: QP242,QP201,QP202,QP203
第 3 页
Cause: The placing sequence does not exist in the production program
(sequence data: N_Data).
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010111
Display: "Specified Position Out Of Range [MX |MYL |MYR |S |SSD |X |Y |Z ]
[+|-]"
Used by: GSP2,GSP3,GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs upon servo axis activation when the specified servo axis destination value has
exceeded the possible movement range.
Remedy: Make sure that the following values are within the normal range: Proper data and production
program data values related to the command or action being executed when the error occurred.
------------------------------
Code: 11010112
Display: "Specified Position Out Of Range Printing [+|-]"
Used by: GSP2,GSP3,GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when the machine tries to move the S-axis to a destination value beyond the
printable range while the near or far squeegee holder is down.
Remedy: Make sure that the following values are within the normal range: Proper data and production
program data values related to the S-axis command or action being executed when the error occurred.
------------------------------
Code: 11010113
Display: "Specified Position Out Of Range Cleaner [+|-]"
Used by: GP6,QP242,QP201,QP202,QP203
Cause: The specified cleaning area (during cleaning) or a specified travel target position (when the cleaner
head is closed) is out of the cleaning range.
Remedy: Designate a cleaning area which is within the cleaner's travel range, or verify that the Proper
Data or production program values related to the cleaner head (GP6 double-side cleaner: S-axis, GP6 one-
side cleaner: Y-axis, GP5: CX-axis) are within the correct range.
------------------------------
Code: 11010121
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 1 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010122
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 2 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010123
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 3 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
第 4 页
Code: 11010124
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 4 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010125
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 4 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010126
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 5 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010201
Display: Program NG 0010
Used by: IP1,QP242,QP201,QP202,QP203
Cause: A next device error occurred during program device check.
Remedy: Check the displayed device data and the next device data.
------------------------------
Code: 11010202
Display: Program NG 0012
Used by: IP1,QP242,QP201,QP202,QP203
Cause: During program device check, a device number that could not be used by the machine was found.
Remedy: Check the displayed device data and next device data numbers.
------------------------------
Code: 11010203
Display:
Used by: IP2,QP242,QP201,QP202,QP203
Cause: The current production program calls for feeders to be placed in a device where there is a tape
pack feeder. The tape pack feeder takes up 11 device positions, so there must be 5 free devices on each
side of the reference device number.
Remedy: Check the production program.
------------------------------
Code: 11010204
Display:
Used by: QP242,QP201,QP202,QP203
Cause: An inappropriate unit number has been specified for the tape pack feeder.
Remedy: The unit number must be between 1 and 4. Check the production program.
------------------------------
Code: 11010205
Display:
Used by: QP242,QP201,QP202,QP203
Cause: An inappropriate magazine number has been specified for the tape pack feeder.
第 5 页