FUJI错误代码查询.pdf - 第1339页
Cause: The length in the Y direction is too long. Remedy: Check that the CCD level and vision processing is operating normally. ------------------------------ Code: 1D0B0006 Display: Used by: Cause: The lead is too long.…
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0AD080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0AE???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0AF???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D0B0001
Display:
Used by:
Cause: The value of the Part data Direction item is not between 0 and 3.
Remedy: Check the value of the Part data Direction item.
------------------------------
Code: 1D0B0002
Display:
Used by:
Cause: The part could not be found.
Remedy: Check the conditions under which the part is being fed.
------------------------------
Code: 1D0B0003
Display:
Used by:
Cause: The value of the Part data Direction item is not between 0 and 3.
Remedy: Check the value of the Part data Direction item.
------------------------------
Code: 1D0B0004
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0005
Display:
Used by:
第 1338 页
Cause: The length in the Y direction is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B0006
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B0007
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B0008
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B0009
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B000A
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B000B
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B000C
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B000D
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
第 1339 页
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B000E
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B000F
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0010
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0011
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0012
Display:
Used by:
Cause: The part is tilted too much.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B0013
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
第 1340 页