FUJI错误代码查询.pdf - 第33页
so that it is within the range established in part data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data. ------------------------------ Code: 11011320 Display: Used …
6/6M/65/642). The applicable part data is that listed in lines 105-117 in "D_data".
Remedy: For the CP4 or CP43, change the value for one of the program
items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size" so that it is within the range established in part
data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data. For the CP-
6/6M/65/642, change the nozzle assignment table to include the nozzles wihtin the range established in
part data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data.
------------------------------
Code: 11011099
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: The nozzle size specified in Part data (Nozzle_size_min.,Nozzle_size_max.) cannot be found in the
program items "S_nozzle_size","M_nozzle_size",or "L_nozzle_size"(CP4,CP43). The nozzle size specified in
Part data (Nozzle_size_min .,Nozzle_size_max .) cannot be found in the nozzle assignment table(CP-
6/6M/65/642). The applicable part data is that listed in lines 118-130 in "D_data".
Remedy: For the CP4 or CP43, change the value for one of the program
items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size" so that it is within the range established in part
data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data. For the CP-
6/6M/65/642, change the nozzle assignment table to include the nozzles wihtin the range established in
part data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data.
------------------------------
Code: 1101109A
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: The nozzle size specified in Part data (Nozzle_size_min.,Nozzle_size_max.) cannot be found in the
program items "S_nozzle_size","M_nozzle_size",or "L_nozzle_size"(CP4,CP43). The nozzle size specified in
Part data (Nozzle_size_min .,Nozzle_size_max .) cannot be found in the nozzle assignment table(CP-
6/6M/65/642). The applicable part data is that listed in lines 131-140 in "D_data".The applicable part
data is that listed in lines 131-143 in "D_data"(CP43).
Remedy: For the CP4 or CP43, change the value for one of the program
items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size" so that it is within the range established in part
data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data. For the CP-
6/6M/65/642, change the nozzle assignment table to include the nozzles wihtin the range established in
part data items,"Nozzle_size_min" and "Nozzle_size_max". Alternatively, change the part data.
------------------------------
Code: 1101109B
Display:
Used by: CP4-3
Cause: The nozzle size specified in Part data (Nozzle_size_min.,Nozzle_size_max.) cannot be found in the
program items "S_nozzle_size","M_nozzle_size",or "L_nozzle_size". The applicable part data is that listed in
lines 144-156 in "D_data".
Remedy: Change the value for one of the program items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size"
so that it is within the range established in part data items,"Nozzle_size_min" and "Nozzle_size_max".
Alternatively, change the part data.
------------------------------
Code: 1101109C
Display:
Used by: CP4-3
Cause: The nozzle size specified in Part data (Nozzle_size_min.,Nozzle_size_max.) cannot be found in the
program items "S_nozzle_size","M_nozzle_size",or "L_nozzle_size". The applicable part data is that listed in
lines 157-160 in "D_data".
Remedy: Change the value for one of the program items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size"
第 32 页
so that it is within the range established in part data items,"Nozzle_size_min" and "Nozzle_size_max".
Alternatively, change the part data.
------------------------------
Code: 11011320
Display:
Used by:
Cause: Part data's nozzle number is not 1 or 2 on a CP.
Remedy: Check Part data.
------------------------------
Code: 11011321
Display:
Used by: CP3
Cause: There is a part higher than 4.5 mm encountered during a sequence (CP).
Remedy: Parts higher than 4.5 mm should be placed at the end of the placing sequences. Refer to Part
data for part heights.
------------------------------
Code: 11011322
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are over 255 mark sequences (Fiducial mark, block skip marks) (CP).
Remedy: Reduce the number of mark sequences.
------------------------------
Code: 11011323
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are mark read sequences for a machine which cannot read marks (CP). Alternately, a
production program with mark read sequences was transmitted but the Proper data has been deleted.
Remedy: Eliminate the mark read sequences if the machine does not read mark read sequences.
Otherwise, re-transmit Proper and Status data to the machine, and then transmit the production
program.
------------------------------
Code: 11011324
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are over 11 next devices set (CP3). There are over 31 next devices set(CP4,CP43, CP-
6/6M/65/642/652C). A next device loop does not exist (the machine never returns to the original device).
Remedy: Reduce the number of next devices. Check the next device settings (make sure a loop is formed).
------------------------------
Code: 11011325
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: In the production program the nozzle diameter is not set correctly (CP4).
Remedy: Set the nozzle diameter in the production program.
------------------------------
Code: 11011326
Display: same as code.
Used by: CP643
Cause: The item "Multiple PCB Set" in the production program indicates double
board production,but the sequence data contains no sequence for the second board.
Remedy: Set the item "Multiple PCB Set" to 1,or enter sequence for the second board.
------------------------------
第 33 页
Code: 11011327
Display: Non
Used by: CP642,CP642M,CP643
Cause: The No.1 nozzle in the nozzle assignment table is less than 0.7 mm in size.
Remedy: Use nozzle of less than 0.7 mm at a position other than No.1.
------------------------------
Code: 11011400
Display:
Used by: GL2,GL541
Cause: The application time (G) is out of range.
Remedy: Check the program.
------------------------------
Code: 11011401
Display:
Used by:
Cause: The application speed (U) is out of range.
Remedy: Check the program.
------------------------------
Code: 11011402
Display:
Used by:
Cause: The feeder specification (F) is not set at 1 or 2.
Remedy: Check the program.
------------------------------
Code: 11011403
Display:
Used by:
Cause: The feeder specification (F) change over on even numbered devices.
Remedy: Check the program.
------------------------------
Code: 11011404
Display:
Used by:
Cause: The DX offset is out of range.
Remedy: Check the program.
------------------------------
Code: 11011405
Display:
Used by:
Cause: The DY offset is out of range.
Remedy: Check the program.
------------------------------
Code: 11011406
Display:
Used by:
Cause: The DQ offset is out of range.
Remedy: Check the program.
------------------------------
Code: 11011600
Display:
Used by: IP2
第 34 页