FUJI错误代码查询.pdf - 第1125页
Cause: The board loader cylinder could not retract. Remedy: Check that there is nothing interfering with the board loaderls ability to move. At the I/O display, toggle OUT1-16 FEEDER FWD and OUT1-17 FEEDER BWD on and off…
Display: Cycle Alarm STOPPER(IP,IP2)
Stopper ascent error!(NP2,QP3)
Used by: IP1,IP2,NP132,NP133,NP2,QP3
Cause: Stopper cylinder alarm.
Remedy: Adjust the advance and retract positions of the stopper cylinder.
------------------------------
Code: 1504030C
Display: Cycle Alarm LOADER NOTCH
Used by: GL2,GL5,GL541,IP1,IP2
Cause: Loader notch cylinder alarm.
Remedy: Adjust the advance and retract positions of the loader notch cylinder.
------------------------------
Code: 1504030D
Display: Cycle Alarm PCB_planer L or R
Used by:
Cause: The board pusher could not operate within the set time limit.
Remedy: Check that the movement of the board pusher is not being interfered with.
------------------------------
Code: 1504030E
Display: Cycle Alarm Lifter U or D
Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6
Cause: The board lifter could not operate within the set time limit.
Remedy: Check that the movement of the board lifter is not being interfered with.
------------------------------
Code: 1504030F
Display: TABLE UWD NG
Used by: CP3
Cause: The XY table could not raise itself.
Remedy: Check that there is nothing interfering with the XY table's guide rail and the in or out-conveyor.
At the I/O display, toggle OUT1-18 TABLE UWD and OUT1-19 TABLE DWD on and off, and check IN2-5
FEEDER FWD.
------------------------------
Code: 15040310
Display: TABLE DWD NG
Used by: CP3
Cause: The XY table could not lower itself.
Remedy: Check that there is nothing interfering with the XY table's guide rail and the in or out-conveyor.
At the I/O display, toggle OUT1-18 TABLE UWD and OUT1-19 TABLE DWD on and off, and check IN2-5
FEEDER FWD.
------------------------------
Code: 15040311
Display: FEEDER FWD NG
Used by: CP3
Cause: The board loader cylinder could not advance.
Remedy: Check that there is nothing interfering with the board loaderls ability to move. At the I/O
display, toggle OUT1-16 FEEDER FWD and OUT1-17 FEEDER BWD on and off, and check IN2-5 FEEDER
FWD.
------------------------------
Code: 15040312
Display: FEEDER FWD NG
Used by: CP3
第 1124 页
Cause: The board loader cylinder could not retract.
Remedy: Check that there is nothing interfering with the board loaderls ability to move. At the I/O
display, toggle OUT1-16 FEEDER FWD and OUT1-17 FEEDER BWD on and off, and check IN2-5 FEEDER
FWD.
------------------------------
Code: 15040313
Display: Feeding Pin DWD NG
Used by: CP3
Cause: The board loader lever could not lower itself.
Remedy: Check the cylinder that raises and lowers this lever. Check the path of the lever for any objects
that might interfere with its movement. At the I/O display, toggle OUT1-14 FEEDING PIN DW and OUT1-
15 FEEDING PIN UP on and off and check IN2-3 FEEDING PIN DW.
------------------------------
Code: 15040314
Display: Feeding Pin UWD NG
Used by: CP3
Cause: The board loader lever could not raise itself.
Remedy: Check the cylinder that raises and lowers this lever. Check the path of the lever for any objects
that might interfere with its movement. At the I/O display, toggle OUT1-14 FEEDING PIN DW and OUT1-
15 FEEDING PIN UP on and off and check IN2-3 FEEDING PIN DW.
------------------------------
Code: 15040315
Display: CHECK XY TABLE CLUTCH
Used by: CP3
Cause: The XY table conveyor movement clutch could not advance or retract.
Remedy: At the I/O display, toggle OUT 2-25 TABLE_CL_ON on and off and check IN5-21
TABLE_CLUTCH.
------------------------------
Code: 15040316
Display: CHECK XY TABLE STOPPER
Used by: CP3
Cause: The XY table stopper could not raise or lower itself in the preset time limit.
Remedy: Check that there is no board stuck at the XY table. At the I/O display, toggle OUT2-27
T_STOPPER_OFF on and off, and check IN5-20 OUT_STOPPER_SW.
------------------------------
Code: 15040317
Display: 电路板搬运错误 MAIN
电路板载入异常(NP2,QP3)
Used by: IP1,NP2,QP3,GPX,NXTP
Cause: 虽然从载入侧搬运轨道上送出了电路板,但是主搬运轨道的电路板到达传感器在规定时间内没有变成电路板
到达的状态。
Remedy: 请检查是否有卡在搬运轨道上的电路板。
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040317.PNG">
------------------------------
Code: 15040318
Display: PCB unloading error!(NP2,QP3)
Used by: NP2,QP3
Cause: The board was supposed to be unloaded from the main conveyor but the board did not reach the
board arrival sensor within the specified time.
Remedy: Check that the board is not stuck on the conveyor.
第 1125 页
------------------------------
Code: 15040319
Display: The conveyor width differs from the board width set in the production program.
Used by: NP-133E
Cause: The width of the board (set at "PCB Size Y" in the production program), differs from the width of
the conveyor. Alternatively, the maximum conveyor width (Proper data item "Conveyor Width Limit") may
have been exceeded.
Remedy: Check the settings at the production program item "PCB Size Y" and the Proper data item
"Conveyor Width Limit".
------------------------------
Code: 15040320
Display: XY-table is out of the loading position range.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table is out of the loading position range.
Remedy: Move the XY-table to the loading position.
------------------------------
Code: 15040321
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side clamp limit signal for the first panel failed to switch
on even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040322
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the first panel failed to
switch off even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040323
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the second panel failed to
switch off even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040324
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side clamp limit signal failed to switch on even
though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 15040325
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side unclamp limit signal failed to switch off even
though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
第 1126 页