Used by: CP652C Cause: Either the shutter between the UP elevator and the PPS6 was open when the UP elevator started moving, or it opened during UP elevator operation. Remedy: Make sure the UP elevator shutter is closed.…

100%1 / 5282
Code: 12054074
Display: "Pal Transport Err OUT->DOWNELV"
Used by: CP652C
Cause: Either the forward end check sensor for the cylinder of the pallet conveyor between the OUT
position and the DOWN elevator has not turned on even though the specified time has elapsed since the
cylinder was instructed to start moving, or the pallet movement complete status was not achieved when
the forward end check sensor turned on. "Pallet movement complete status" is as follows: when the pallet
OUT cylinder forward end check sensor turns on, the pallet OUT cylinder retract end check sensor sho ld
be off, the OUT position pallet check sensor should be on, the DOWN elevator pallet check sensor should
be off, and the DOWN elevator pallet passage check sensor should be on.
Remedy: Make sure that nothing is obstructing pallet movement. If there is no obstruction, perform an
I/O check on the input from the following sensors: pallet OUT cylinder forward end check (X0A8) and
retract end check (X0A9), OUT position pallet check (X047), DOWN elevator pallet check (X0A4), and
DOWN elevator pallet passage check (X0A5). Adjust the sensors as necessary.
------------------------------
Code: 12054075
Display: "Pal Transport Err DOWNELV->RCONV"
Used by: CP652C
Cause: The forward end check sensor for the cylinder of the pallet conveyor between the DOWN elevator
and the return conveyor has not turned on even though the specified time has elapsed since the cylinder
was instructed to start moving, or the pallet movement complete status was not achieved when the
forward end check sensor turned on. "Pallet movement complete status" is as follows: when the return
conveyor pallet IN cylinder forward end check sensor turns on, the return conveyor pallet IN cylinder re
ract end check sensor should be off, the return conveyor full sensor should be on, the DOWN elevator full
sensor should be on, the DOWN elevator pallet check sensor should be off, and the DOWN elevator pallet
passage check sensor should be on.
Remedy: Make sure that nothing is obstructing pallet movement. If there is no obstruction, perform an
I/O check on the input from the following sensors: return conveyor pallet IN cylinder forward end check
(X09C) and retract end check (X09D), return conveyor full (X09F), DOWN elevator pallet check (X0A4), and
DOWN elevator pallet passage check (X0A5). Adjust the sensors as necessary.
------------------------------
Code: 12054076
Display: "PAL.OUT Cylinder Time Out"
Used by: CP652C
Cause: Either the retract end check sensor for the pallet OUT cylinder has not turned on even though the
specified time has elapsed since the cylinder was instructed to start retracting, or both the forward end
and retract end check sensors have turned on.
Remedy: Make sure that nothing is obstructing operation. If there is no obstruction, perform an I/O
check on the input from the following sensors: pallet OUT cylinder forward end check (X0A8) and retract
end check (X0A9). Adjust the sensors as necessary.
------------------------------
Code: 12054077
Display: "UP ELV Pallet Stopper is OFF"
Used by: CP652C
Cause: Either the UP elevator pallet stopper or the UP elevator pallet end stopper is off even though the
UP elevator is operating while carrying a pallet.
Remedy: Check the UP elevator pallet stopper sensors (X08C and X08D) and the UP elevator pallet end
stopper sensors (X08A and X08B).
------------------------------
Code: 12054078
Display: "UP ELV Shutter Not Closed"
第 557 页
Used by: CP652C
Cause: Either the shutter between the UP elevator and the PPS6 was open when the UP elevator started
moving, or it opened during UP elevator operation.
Remedy: Make sure the UP elevator shutter is closed.
------------------------------
Code: 12054079
Display: "UP ELV Pal.Stopper Time Out"
Used by: CP652C
Cause: Either a sensor for the UP elevator pallet stopper has not turned on even though the specified
time has elapsed since the stopper was instructed to start operation, or both the stopper ON and OFF
check sensors have turned on.
Remedy: Make sure that nothing is obstructing stopper operation. If there is no obstruction, perform an
I/O check on the input from the following sensors: UP elevator pallet stopper ON (X08C) and OFF (X08D).
Adjust the sensors as necessary.
------------------------------
Code: 1205407A
Display: "UP ELV Pal.END STP Time Out"
Used by: CP652C
Cause: Either an sensor for the UP elevator pallet end stopper has not turned on even though the
specified time has elapsed since the stopper was instructed to start operation, or both the end stopper ON
and OFF check sensors have turned on.
Remedy: Make sure that nothing is obstructing stopper operation. If there is no obstruction, perform an
I/O check on the input from the following sensors: UP elevator pallet end stopper ON (X08A) and OFF
(X08B). Adjust the sensors as necessary.
------------------------------
Code: 1205407B
Display: "PAL IN Cylinder end error"
Used by: CP652C
Cause: The pallet IN cylinder has left the retract end even though the UP elevator is operating while
carrying a pallet.This error could also occur if the retract end check sensor for the pallet INcylinder has
not turned on even though the specified time has elapsed since the cylinder was instructed to start
retracting, or if both the forward end and retract end check sensors have turned on.
Remedy: Make sure that nothing is obstructing operation. If there is no obstruction, perform an I/O
check on the input from the following sensors: pallet IN cylinder forward end check (X088) and retract end
check (X089).Adjust the sensors as necessary.
------------------------------
Code: 1205407C
Display: "SETUP_ST. IN STP. Time Out"
Used by: CP652C
Cause: The in-setup station stopper did not complete its operation in the 3 seconds allowed.
Remedy: Check that there is nothing obstructing the stopper's movement.
Check the I/O signals for the in-setup station stopper's engaged (X090) and disengaged (X091) positions.
------------------------------
Code: 1205407D
Display: "R.Conv Pal Stopper Time Out"
Used by: CP652C
Cause: Either a sensor for the return conveyor pallet stopper has not turned on even though the
specified time has elapsed since the stopper was instructed to start operation, or both the stopper ON and
OFF check sensors have turned on.
Remedy: Make sure that nothing is obstructing stopper operation. If there is no obstruction, perform an
I/O check on the input from the following sensors: return conveyor pallet stopper ON (X098) and OFF
第 558 页
(X099). Adjust the sensors as necessary.
------------------------------
Code: 1205407E
Display: "Pal Transport Err RCONV->UPELV"
Used by: CP652C
Cause: The forward end check sensor for the cylinder of the pallet conveyor between the return conveyor
and the UP elevator has not turned on even though the specified time has elapsed since the cylinder was
instructed to start moving, or the pallet movement complete status was not achieved when the forward
end check sensor turned on."Pallet movement complete status" is as follows: when the return conveyor
pallet OUT cylinder forward end check sensor turns on, the return conveyor pallet OUT cylinder re ract
end check sensor should be off, the return conveyor pallet arrival check sensor should be off, the UP
elevator pallet check sensor should be on, and the UP elevator pallet passage check sensor should be on.
Remedy: Make sure that nothing is obstructing pallet movement. If there is no obstruction, perform an
I/O check on the input from the following sensors: return conveyor pallet OUT cylinder forward end check
(X09A) and retract end check (X09B), return conveyor pallet arrival check (X09E), UP elevator pallet check
(X084), and UP elevator pallet passage check (X085). Adjust the sensors as necessary.
------------------------------
Code: 1205407F
Display: "Pallet_Clamp Error DF or DR"
Used by: CP652C
Cause: The DF-axis (or DR-axis) has failed to clamp a pallet, or a clamp status check performed during
DF-axis (or DR-axis) operation has shown that a pallet is not clamped properly.
Remedy: Make sure that the DF-axis and DR-axis clamps are functioning normally. Perform I/O checks
on input from the following sensors: pallet clamp check (X058 and X05B), pallet unclamp check (X059and
X05C), and pallet check (X05A and X05D) for the DF-axis and DR-axis. Adjust the sensors as necessary.
When a pallet is clamped, the sensors for that axis should be as follows: the pallet clamp and pallet check
sensors should be on, and the pallet unclamp check sensor should be off.
------------------------------
Code: 12054080
Display: " R.Conv IN(OUT) Cylinder Time Out"
Used by: CP652C
Cause: Either the retract end check sensor for the return conveyor pallet IN or OUT cylinder has not
turned on even though the specified time has elapsed since the cylinder was instructed to start retracting,
or both the forward end and retract end check sensors have turned on.
Remedy: Make sure that nothing is obstructing cylinder operation.If there is no obstruction, perform an
I/O check on the input from the following sensors: return conveyor pallet IN and OUT cylinderforward end
check (X09A and X09C) and retract end check (X09B and X09D). Adjust the sensors as necessary.
------------------------------
Code: 12054081
Display: "Pallet_Unclamp Error DF or DR"
Used by: CP652C
Cause: The DF-axis (or DR-axis) has failed to unclamp a pallet.
Remedy: Make sure that the DF-axis and DR-axis unclamp operation is functioning normally.Perform I/O
checks on input from the following sensors: pallet clamp check (X058 and X05B), pallet unclamp check
(X059 and X05C), and pallet check (X05A and X05D) for the DF-axis and the DR-axis. Adjust the sensors
as necessary. When a pallet is unclamped, the sensors for that axis should be as follows: the pallet clamp
and pallet check sensors should be off, and the pallet unclamp check sensor should be on.
------------------------------
Code: 12054082
Display: "ST11:Nozzle up/down error.", "ST11:Check cylinder." (CP6,6M)]