FUJI错误代码查询.pdf - 第1080页

Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the application pressure, the application time(the Apply Volume), the lower limit timer, and the lower limit height. If glueappl…

100%1 / 5282
Used by: GL2,GL5
Cause: The color of the first search point is the color specified in GL2 Glue Black0 or White1, but the
edge of the glue dot could not be found.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030002
Display: er0002
Used by: GL2,GL5
Cause: The color of the first search point is not the color specified in GL2 Glue Black0 or White1, but the
edge of the glue dot could not be found.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030003
Display: er0003
Used by: GL2,GL5
Cause: The size of the glue dot is too big for the edge to be detected.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030004
Display: er0004
Used by:
Cause: Noise was discovered, or neighboring dots are too close to distinguish between them.
Remedy: If the application is stable, check that the vision processing system is taking the image correctly.
If it isn't, check the CCD level and the GL2 Glue Black0 or Whitel setting. Refer to the FCP-II Operation
Manual for further details.
------------------------------
Code: 14030005
Display: er0005
Used by: GL2,GL5,GL541,(QP3)
Cause: The glue application point is too large.
Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the
application pressure, the application time(the Apply Volume), the lower limit timer, and the lower limit
height. If glueapplication is normal, make sure that the image is scanned correctly. If the image is not
scanned correctly, check the CCD level and the "GL2 Glue Black0 or White1" parameter in the program's
headerdata(check the CCD level and the "Mark Color" parameter in the program). (For details, see
Chapter 3, "Automatic operation and programming" and Chapter 2, "Glue checking" in t e FGL-2
Operation Manual.)
------------------------------
Code: 14030006
Display: er0006
Used by: GL2,GL5,GL541,(QP3)
Cause: The glue application point is too small.
第 1079 页
Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the
application pressure, the application time(the Apply Volume), the lower limit timer, and the lower limit
height. If glueapplication is normal, make sure that the image is scanned correctly. If the image is not
scanned correctly, check the CCD level and the "GL2 Glue Black0 or White1" parameter in the program's
headerdata(check the CCD level and the "Mark Color" parameter in the program). (For details, see
Chapter 3, "Automatic operation and programming" and Chapter 2, "Glue checking" in t e FGL-2
Operation Manual.)
------------------------------
Code: 14030010
Display: er0010
Used by: GL2,GL5
Cause: The center space between two application points at 0[deg] and 180[deg] is too large.
Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the
application pressure, the application time, the lower limit timer, and the lower limit height. If
glueapplication is normal, make sure that the image is scanned correctly. If the image is not scanned
correctly, check the CCD level and the "GL2 Glue Black0 or White1" parameter in the program's
headerdata. (For details, see Chapter 3, "Automatic operation and programming" and Chapter 2, "Glue
checking" in t e FGL-2 Operation Manual.)
------------------------------
Code: 14030011
Display: er0011
Used by: GL2,GL5,GL541
Cause: One of two application points at 0[deg] and 180[deg] is smaller than the other. (It is smaller than
the diameter of the larger point, minus the amount specified by the "Glue check limit" parameter.)
Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the
application pressure, the application time, the lower limit timer, and the lower limit height. If
glueapplication is normal, make sure that the image is scanned correctly. If the image is not scanned
correctly, check the CCD level and the "GL2 Glue Black0 or White1" parameter in the program's
headerdata. (For details, see Chapter 3, "Automatic operation and programming" and Chapter 2, "Glue
checking" in t e FGL-2 Operation Manual.)
------------------------------
Code: 14030012
Display: er0012
Used by: GL2,GL5
Cause: The center is too large for a 90 deg. or 270 deg. double-dot application.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030013
Display: er0013
Used by: GL2,GL5,GL541
Cause: One of two application points at 90[deg] and 270[deg] is smaller than the other. (It is smaller
than the diameter of the larger point, minus the amount specified by the "Glue check limit" parameter.)
Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the
application pressure, the application time, the lower limit timer, and the lower limit height. If
glueapplication is normal, make sure that the image is scanned correctly. If the image is not scanned
correctly, check the CCD level and the "GL2 Glue Black0 or White1" parameter in the program's
headerdata. (For details, see Chapter 3, "Automatic operation and programming" and Chapter 2, "Glue
checking" in t e FGL-2 Operation Manual.)
第 1080 页
------------------------------
Code: 14040001
Display: 14040001
Used by:
Cause: The nozzle could not be found.
Remedy: Check the condition under which parts are being supplied.
------------------------------
Code: 14040002
Display: 14040002
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040003
Display: 14040003
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040004
Display: 14040004
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040005
Display: 14040005
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040006
Display: 14040006
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040007
Display: 14040007
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
第 1081 页