Code: 1D33D080
Display: Same as code.
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D33D100
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D33E???
Display: Same as code.
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions. In particular, check for soiling of the nozzle, and make sure that the
CCD level is correct.
------------------------------
Code: 1D33F???
Display: Same as code.
Used by:
Cause: There is a logical error in the processing program. The part cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the part.
Remedy: Check the Part data.
------------------------------
Code: 1D340002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is too large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D344006
Display: Same as code.
Used by:
Cause: The part's inclination is execessive.
Remedy: Check the part's shape and supply direction.
------------------------------
Code: 1D344041
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D344042
Display: Same as code.
第 1658 页
Used by:
Cause: The part could not be found.
Remedy: Check the Part data, and the manner in which the part is picked up.
------------------------------
Code: 1D344043
Display: Same as code.
Used by:
Cause: The part's outline could not be identified.
Remedy: Check the image acquisition conditions.
------------------------------
Code: 1D344044
Display: Same as code.
Used by:
Cause: The part's size is outside the allowable range.
Remedy: Check the part's shape and supply direction.
------------------------------
Code: 1D344045
Display: Same as code.
Used by:
Cause: The parts inclination is greater than 15%, or the four sides are not equally inclined.
Remedy: Check the manner in which the part is picked up, and the part's shape.
------------------------------
Code: 1D348002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D348100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D348110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D348111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D348112
Display: Same as code
Used by:
第 1659 页
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D348113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D348114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D348115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D348120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D348121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D348122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D348123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.