FUJI错误代码查询.pdf - 第1296页

Used by: Cause: The Y length of the part exceeds the permitted range. Remedy: Check the size of the part. ------------------------------ Code: 1D05000C Display: Used by: Cause: Vision processing cannot take a correct par…

100%1 / 5282
Cause: A level area was not found in the Y direction.
Remedy: Check the part shape. Check the pickup conditions. Check the Part data Y axis length.
------------------------------
Code: 1D050004
Display:
Used by:
Cause: A Y length cannot be determined.
Remedy: Check the part shape. Check the pickup conditions. Check the Part data Y axis length.
------------------------------
Code: 1D050005
Display:
Used by:
Cause: The Y length of the part exceeds the permitted range.
Remedy: Check the size of the part.
------------------------------
Code: 1D050006
Display:
Used by:
Cause: An X length cannot be determined.
Remedy: Check the Part data X axis length. Check the part shape.
------------------------------
Code: 1D050007
Display:
Used by:
Cause: An X length cannot be determined.
Remedy: Check the Part data X axis length. Check the part shape.
------------------------------
Code: 1D050008
Display:
Used by:
Cause: The X length of the part exceeds the permitted range.
Remedy: Check the size of the part.
------------------------------
Code: 1D050009
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D05000A
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D05000B
Display:
第 1295 页
Used by:
Cause: The Y length of the part exceeds the permitted range.
Remedy: Check the size of the part.
------------------------------
Code: 1D05000C
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D05000D
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D05000E
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D05000F
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D050010
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D058002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
第 1296 页
------------------------------
Code: 1D058100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D058110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D058111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D058112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D058113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D058114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D058115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D058120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D058121
Display:
第 1297 页