"Reset PLC failed" (QP2) Used by: QP201,QP202,QP203 Cause: The PLC alarm cannot be cleared. (value replacing "?" is module number; error code appears in place of asterisks) Remedy: Turn the power to t…

100%1 / 5282
error.
For the QP-201E-CTL, this error is caused by a FOL carrier conveyance error (clamping / unclamping time
out), package clamping / unclamping time out, package positioning error, or the detection of unremoved
packages.
The question marks (?) represent the module number. The asterisks (*) represent the error code.
Remedy: On the QP-201E-APL ensure that nothing is interfering with the movement of the clamping unit,
and that the raised and lowered limit sensors are functioning correctly. Check that clamping is being
performed correctly. Check that all parts are correctly positioned in the pockets. Check the action of the
vacuum pads.
On the QP-201E-CTL ensure that nothing is interfering with the movement of the clamping unit, and that
the raised and lowered limit sensors are functioning correctly. Check that clamping is being performed
correctly. Check that all packages are correctly removed from the FOL carrier.
------------------------------
Code: 1207E?58
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Tray / Tray Unit Full" (QP2)
Used by: QP242,QP201
Cause: (APL) There are no supply trays or, the unloading elevator is full.
(value replacing "?" is module number; error code appears in place of asterisks)
(CTL) There are no storage trays or, the unloading elevator is full.
Remedy: (APL) Load supply trays or remove the empty trays.
(CTL) Load storage trays or remove the finished trays.
------------------------------
Code: 1207E?59
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Removal Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The tray removal operation is not complete.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place the tray to be removed onto the unloading elevator and execute the tray unit positioning
command.
------------------------------
Code: 1207E?5A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Supply Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The tray supply operation is not complete.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place the empty tray onto the unloading elevator and execute the tray unit positioning
command.
------------------------------
Code: 1207E?5B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Check PLC Alarm" (QP2)
Used by: QP201,QP202,QP203
Cause: The PLC alarm has not been cleared.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the PLC alarm.
------------------------------
Code: 1207E?5C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
第 830 页
"Reset PLC failed" (QP2)
Used by: QP201,QP202,QP203
Cause: The PLC alarm cannot be cleared.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power to the machine off and on.
------------------------------
Code: 1207E?5D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC and PLC are Dead Locked" (QP2)
Used by: QP201,QP202,QP203
Cause: Automatic operation cannot be started because the head and the tray are dead locked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Move the head away from the area of interference.
------------------------------
Code: 1207E?5E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray unit interlock alarm" (QP2)
Used by: QP201,QP202,QP203
Cause: Automatic operation cannot be started because the tray is interlocked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Move the head away from the area of interference.
------------------------------
Code: 1207E?5F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Pstn'g time-out (PLC Tray)" (QP2)
Used by: QP201,QP202,QP203
Cause: The tray positioning operation timed out.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the shuttle movement as well as the extend and retract position sensors. Check the rail
open/close sensor. Check the TZ-axis movement.
------------------------------
Code: 1207E?60
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PLC System Error" (QP2)
Used by: QP201,QP202,QP203
Cause: This is a sequencer servo error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Shut the power off.
------------------------------
Code: 1207E?61
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PLC Tray alarm" (QP2)
Used by: QP201,QP202,QP203
Cause: This is a sequencer operation error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the shuttle movement as well as the extend and retract position sensors. Check the rail
open/close sensor. Check the TZ-axis movement.
------------------------------
Code: 1207E?62
Display: "ICM(PMC?,SCU?) Error Code:********"
"Empty tray pickup error"
第 831 页
Used by: QP242,NP2,QP3
Cause: Failed to pick-up an empty tray during its removal.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the remover has sufficient vacuum pressure. Also, ensure an error has not occurred
at the empty tray pick-up confirmation sensor (TRAY PICKUP CHK).
------------------------------
Code: 1207E?63
Display: "ICM(PMC?,SCU?) Error Code:********"
"No clip tray"
Used by: QP203
Cause: The machine has run out of spring clip trays.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Supply spring clip trays.
------------------------------
Code: 1207E?64
Display: "ICM(PMC?,SCU?) Error Code:********"
"No spreader/clip tray"
Used by: QP203
Cause: The machine has run out of heat spreader and spring clip trays.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Supply heat spreader and spring clip trays.
------------------------------
Code: 1207E?66
Display: "ICM(PMC?,SCU?) Error Code:********"
"Heat spreader parts out"
Used by: QP203
Cause: Heat spreader parts have run out.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Re-supply spreader parts.
------------------------------
Code: 1207E?67
Display: "SCU? (PMC?, ICM) Error Code:********"
"Dip flux unit alarm"
Used by: QP242
Cause: An alarm occurred during the operation of the dip flux unit.
Remedy: Check that the air supply is connected properly, or that the sequencer is operating correctly.
------------------------------
Code: 1207E?68
Display: "SCU? (PMC?, ICM) Error Code:********"
"Dip flux unit time out"
Used by: QP242
Cause: The dip flux unit did not complete its operation within the specified time limit."
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check that the power supply is connected properly.
------------------------------
Code: 1207E?69
Display: "SCU? (PMC?, ICM) Error Code:********"
"Failed to rec X calib data"
Used by: QP242
Cause: Failed to receive X-axis calibration data from the LLL.