FUJI错误代码查询.pdf - 第1962页

Remedy: Check the PST file device number. ------------------------------ Code: 21007732 Display: Cartridge type unmatch Used by: Cause: The feeder type is incorrect. Remedy: Check the feeder type. -----------------------…

100%1 / 5282
Display: File data type unmatch.
Used by:
Cause: The input program data type is inappropriate.
Remedy: Check the file.
------------------------------
Code: 2100772A
Display: File machine type unmatch
Used by:
Cause: The input program data type is inappropriate.
Remedy: Check the file.
------------------------------
Code: 2100772B
Display: Production file expand error
Used by:
Cause: During expansion of the input program, an error occurred.
Remedy: Use [Cntrl] + [E] to check the contents of the expander.
------------------------------
Code: 2100772C
Display: Not get Part data file name
Used by:
Cause: A Part data name is not entered in the device number being used in Sequence data.
Remedy: Check the Part data name in the production program device data.
------------------------------
Code: 2100772D
Display: Not get Nozzle assignment table file name
Used by:
Cause: The nozzle table file name was not entered in the production program.
Remedy: Input the table file name.
------------------------------
Code: 2100772E
Display: Not get nozzle size
Used by:
Cause: The nozzle size cannot be called up.
Remedy: Check the nozzle table.
------------------------------
Code: 2100772F
Display: Same davice comment entry in PST file
Used by:
Cause: A device comment with the same name exists in the PST file.
Remedy: The same name cannot be used. Change the comment.
------------------------------
Code: 21007730
Display: No entry Cartridge name in PST file
Used by:
Cause: The feeder name has not been entered in the PST file.
Remedy: Input the feeder name.
------------------------------
Code: 21007731
Display: Can not feedback Fix device
Used by:
Cause: Unable to feed back the fixed device. The fixed device's device number is incorrect.
第 1961 页
Remedy: Check the PST file device number.
------------------------------
Code: 21007732
Display: Cartridge type unmatch
Used by:
Cause: The feeder type is incorrect.
Remedy: Check the feeder type.
------------------------------
Code: 21007733
Display: No used Cartridge
Used by:
Cause: An unused feeder exists.
Remedy: Check the file.
------------------------------
Code: 21007734
Display: Can not setting Fix device data
Used by:
Cause: Unable to set the fixed device number.
Remedy: Check the PST file device number.
------------------------------
Code: 21007735
Display: Can not setting Next device data
Used by:
Cause: As there are too many devices in use, the next device cannot be set.
Remedy: Reduce the number of devices in use.
------------------------------
Code: 21007736
Display: Next device change station
Used by:
Cause: The next device is on a different pallet from the original device.
Remedy: This message occurs when the next device is on a different pallet from the original device. Set
the next device on the same pallet.
------------------------------
Code: 21007737
Display: Not found next device
Used by:
Cause: The next device was not found.
Remedy: This warning message appears when there is no next device specified in the program.
------------------------------
Code: 21007738
Display: Not get Cartridge name
Used by:
Cause: Unable to retrieve the feeder name.
Remedy: Check that the Part data has been entered correctly.
------------------------------
Code: 21007739
Display: Station over
Used by:
Cause: The device cannot be placed in the station.
Remedy: Join the feeders. Alternately, stop using the PST or the base program.
------------------------------
第 1962 页
Code: 2100773A
Display: Not get Occupancy data
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100773B
Display: Not get Slot info data
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100773C
Display: New production file has no sequence
Used by:
Cause: There are no sequences in the new program file.
Remedy: Check the input file.
------------------------------
Code: 2100773D
Display: Parts height regulation over
Used by:
Cause: The part height exceeds the set limit.
Remedy: Check the Part data part height.
------------------------------
Code: 2100773E
Display: Different cartridge name in PST file
Used by:
Cause: The feeder name in the PST file is wrong.
Remedy: Check the PST file feeder name.
------------------------------
Code: 2100773F
Display: Input program file name is too long
Used by:
Cause: The input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007740
Display: Output program file name is too long
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007741
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 21007742
Display: Base program file name is too long
Used by:
第 1963 页