Cause: MFU has not been set. Remedy: Set the MFU. ------------------------------ Code: 12050404 Display: "Remove D1-3" (IP2) Used by: Cause: A tape feeder or stick feeder has been attached to D1, D2, or D3 on a…
------------------------------
Code: 1205030C
Display: Servo error PO-axis:Over travel
Used by: QP132
Cause: The PO-axis is in overtravel.
Remedy: Correct the position of the PO-axis using the inching keys.
------------------------------
Code: 1205030D
Display: Y-axis collision!
Used by: NP2,QP3
Cause: The Y-axis collision sensor has been triggered. There is interference between the Y1 and Y2
axis.(NP2,QP3)
Remedy: Use the inching keys to clear the interference.(NP2,QP3)
------------------------------
Code: 1205030E
Display: 往复臂 O.T.异常
Used by: NXTP
Cause: 往复臂的移动目标值为范围外,从属搬运轨道越过超程传感器。
Remedy: 请向前侧移动,解除传感器。
<img src="$LKEY_ERRIMG_MC$/1205030E.PNG">
------------------------------
Code: 1205031?
Display: Servo Ararm ? axis. Overtravel. (CP6)
Used by:
Cause: Overtravel error at the ? axis.
Remedy: Use inching to clear the overtravel condition.
------------------------------
Code: 12050311
Display: 伺服报错 超程
Used by: GPX-C
Cause: 显示位置上发生超程现象。
Remedy: 请使用微操作或手操作解除超程现象。
------------------------------
Code: 12050401
Display: 内存备份不良 Memory Backup NG (IP,IP2,GSP)
Used by: GPX,IP, IP2, GSP,NXTP
Cause: 有效的Proper和Status没有被传输。
Remedy: 请传输Proper和Status。此时,在传输Proper和Status后,暂时关闭电源然后重新接通。 (有可能伺服的
动作不正常)在每次接通电源后发生时,请检查备份用的电池。进行了复位后也会显示该错误。
<img src="$LKEY_ERRIMG_MC$/12050401.PNG">
------------------------------
Code: 12050402
Display: "Data Transmission Line NG" (IP, GL), "Transmiterr" (CP3)
Used by: GL2
Cause: The machine cannot transmit data to the MCS-16. The memory buffer has become full due to a
failure in communication with the MCS-16.
Remedy: Check the communication cable. Make sure the MCS-16 is not hung up.
------------------------------
Code: 12050403
Display: MFU1 (2) is not ready
Used by: IP2
第 511 页
Cause: MFU has not been set.
Remedy: Set the MFU.
------------------------------
Code: 12050404
Display: "Remove D1-3" (IP2)
Used by:
Cause: A tape feeder or stick feeder has been attached to D1, D2, or D3 on an FIP-series machine
equipped with an MTU.
Remedy: Remove tape feeders and stick feeders from D1, D2, and D3.
------------------------------
Code: 12050405
Display: "Thermal alarm" (GSP, GL, CP5), "PCM THERMAL Alarm" (CP651C)
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3,QP132
Cause: A servo motor thermal relay has been tripped.On the CP651C, an alarm has been detected by a
thermal relay on one of the following motors: UP elevator, DOWN elevator, or return conveyor.
Remedy: Make sure the servo axes are not overloaded. Inspect the connectors and wiring for motors and
servo amps. Press the thermal relay's reset button to cancel the error.
------------------------------
Code: 12050406
Display: Ready For Program NG
Used by:
Cause: A program has not been transmitted.
Remedy: Transmit a program from MCS.
------------------------------
Code: 12050407
Display: " 冷却装置警告 ", " Cooler Alarm "(GSP,GL)
Used by: GL2,GSP2,GSP3,GP2,GP3,GPX,NXTP
Cause: 超出了温调用的操作画面上所设定的温度调整的范围。
Remedy: 请确认温调用的开关是否开启。如果开关开启着,请检查加热器和冷却装置是否发生了异常,另外,温度调
整范围的设定是否正确。
<img src="$LKEY_ERRIMG_MC$/12050407.PNG">
------------------------------
Code: 12050408
Display: " 加热器警告 ", " Heater Alarm "(GSP,GL)
Used by: GL2,GSP2,GSP3,GP2,GP3,GPX,NXTP
Cause: 超出了温调用的操作画面上所设定的温度调整的范围。
Remedy: 请确认温调用的开关是否开启。如果开关开启着,请检查加热器和冷却装置是否发生了异常,另外,温度调
整范围的设定是否正确。
<img src="$LKEY_ERRIMG_MC$/12050408.PNG">
------------------------------
Code: 12050409
Display: "Zero Set NG"
Used by:
Cause: Zero setting has not been performed.
Remedy: Perform zero setting.If the machine has stopped part of the way through zero setting after the
START button is pressed, the display will indicate which axes have not been zeroed. Press
theEMERGENCY STOP button, turn off the power supply, and check the axes in question for
abnormalities. (Check the zero-setting sensors, motors, cables, and amps; check for mechanical
interference; etc.)
------------------------------
第 512 页
Code: 1205040A
Display: Pallet system error
Used by: CP5
Cause: The pallet control software is defective.
Remedy: Contact Fuji.
------------------------------
Code: 1205040B
Display: 存在着无法读取定位点的顺序
[Mark seq. not processed]
Used by: GP2,GP3,IP3,QP132,GPX,NXTP
Cause: 读取BadMark的时候,或者,没有读取在贴装元件时参照的基准定位点。 没有发现钢板的定位点。 (GPX)
Remedy: 发生在没有对应「自动重新读取定位点」的机型。请重新读取定位点。 1.请确认定位点是否弄脏。
2.请确认定位点形状或检索范围是否被正确设定了。(GPX)
<img src="$LKEY_ERRIMG_MC$/1205040B.PNG">
------------------------------
Code: 1205040C
Display: ST2 Parts chk sensor err.
Used by: CP-IV/IV-2(SMD3), CPIV-3/6/6M/642/65/652C
Cause: There is a sensor error at station 2, large part check.
This could be caused by misalignment of the light beam in the sensor, a broken wire leading to the sensor
part that emits the beam, or the entire sensor itself may be malfunctioning.
Remedy: If there is a problem with the alignment of the light beam, adjust the beam. If there is a problem
with the part of the sensor that emits the light beam, after determining the cause of the error, replace the
sensor, rewire the sensor, etc.
Additionally, check station 2 to verify that a part has been picked up, and examine the device feeder.
------------------------------
Code: 12050410
Display: I/O system error!
Used by: NP2,QP3
Cause: An error occurred in the I/O system.
Remedy: Restart the machine.
------------------------------
Code: 12050411
Display: MFU Proper data writing error
Used by: NP2,QP3
Cause: MFU Proper data writing failed.
Remedy: This is a LON communication error. Restart the machine.
------------------------------
Code: 12050412
Display: MTU Proper data writing error
Used by: NP2,QP3
Cause: MTU Proper data writing failed.
Remedy: This is a LON communication error. Restart the machine.
------------------------------
Code: 12050413
Display: PFU Proper data writing error
Used by: NP2,QP3
Cause: PFU Proper data writing failed.
Remedy: This is a LON communication error. Restart the machine.
------------------------------
Code: 12050414
第 513 页