FUJI错误代码查询.pdf - 第1092页
Remedy: Make sure the in-lifter operates smoothly. Make sure the upper and lower limit sensors have been attached at the correct positions. Make sure the upper and lower limit sensors (the I/O input signals listed below)…
Cause: A board unload or a change command was sent when there was no board. If there is a board on
the conveyor, an attempt was made to load the board. If there is no board on the conveyor, an attempt
was made to unload the board.
Two boards are present even though single board production is in effect.
Two boards are present even though a single board feed instruction was issued during double board
production.
The in-conveyor cannot convey boards due to poor board positioning.
The status of boards in the in-conveyor cannot be checked.
Remedy: Input the correct command. Check the conveyor conditions. and check that the command can
in fact be carried out. Otherwise, use the I/O to check that the board arrived sensor on the conveyor is
operational.
Set boards in the in-conveyor so that the quantity of boards is appropriate to the production method in
effect.
Set boards in the correct positions.
Make sure the in-conveyor board sensors (the I/O input signals listed below) correctly detect the presence
of boards in the conveyor. The board gap sensor should be ON when there is no board,and OFF when a
board is present.
I/O input signals(CP643):
LX003: IN1 board deceleration start point sensor
LX004: IN1 board arrival sensor
LX007: IN1/IN2 board gap sensor
LX008: IN2 board deceleration start point sensor
LX009: IN2 board arrival sensor
LX017: IN-conveyor board load sensor
------------------------------
Code: 15010404
Display: Conv. PLC Alarm : IN
Board check error:I_LIFT
Should be no brd on in-lift Chk brd status
Used by: CP5,CP642,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not working properly.
The in-lifter board sensors are abnormal. ( For example,a sensor is ON
even though it should be OFF.
Remedy: Contact Fuji.
Make sure the in-conveyor board sensors (the I/O input signals listed below) tuen ON and OFF correctly.
The board gap sensor should be ON when there is no board,and OFF when a board is present.
I/O input signals(CP643):
LX003: IN1 board deceleration start point sensor
LX004: IN1 board arrival sensor
LX007: IN1/IN2 board gap sensor
LX008: IN2 board deceleration start point sensor
LX009: IN2 board arrival sensor
------------------------------
Code: 15010405
Display: Cylinder cycle alarm:I_LIFT
Up/down movement of the I_LIFT time up
Used by: CP643
Cause: The in-lifter was raised,but the upper limit sensor did not turn ON within the specified time.
The in-lifter was lowered,but the lower limit sensor did not turn ON within the
specified time.
The in-lifter upper and lower limit sensors are both ON.
第 1091 页
Remedy: Make sure the in-lifter operates smoothly.
Make sure the upper and lower limit sensors have been attached at the correct positions.
Make sure the upper and lower limit sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the upper and lower limit sensors (the I/O input signals listed below) turn ON and OFF
correctly when the in-lifter is raised and lowered.
I/O input signals:
LX01E: IN-lifter upper limit sensor
LX01F: IN-lifter lower limit sensor
------------------------------
Code: 15010501
Display: PCB Transport Error: MAIN
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP642,GL5,GL541,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between the main conveyors exceeded the preset limit.
The appropriate removal setting between conveyors is made (1:ON 2:OFF 3:OFF).
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010502
Display: PCB Stopper Error: MAIN
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP642,GL5,GL541,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010503
Display: Command Error: MAIN
Used by: CP5,CP6,CP6M,CP65,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010504
Display: Conv. PLC Alarm: MAIN
PCB Transport Error:I_LIFT
Deceleration sensor
does not turn on
Used by: CP5,CP642,GSP5,GP2,GP3,GP551,GP6,IP3,CP643
Cause:
Remedy:
------------------------------
Code: 15010601
Display: PCB Transport Error: OUT
PCB Transport Error:O_LIFT
Chk brd conveyance at O-cnv
Used by: CP4-1,CP4-2,CP4-
第 1092 页
3,CP5,CP6,CP6M,CP65,CP642,CP643,GL5,GL541,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between each conveyor exceeded the preset limit. The
appropriate setting is made (1:ON 2:OFF 3:OFF). Three seconds after the deceleration point is activated
the board start point is not on, an alarm occurs and the machine is stopped.
The out-conveyor failed to convey a board (or boards) correctly.
Remedy: Check the out-conveyor width.
Check that there is no board stuck between this point and the previous production stage.
Check the out-conveyor width.
Make sure the out-conveyor board sensors (the I/O input signals listed below) correctly detect the
presence of boards on the conveyor. The board gap sensor should be ON when there is no boards,and OFF
when a board is present.
I/O input signals(CP643):
LX00C: OUT1/OUT2 board gap sensor
LX00D: OUT-conveyor board arrival sensor
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010602
Display: PCB Stopper Error: OUT
PCB Stopper Error:O_LIFT
Check board-stopper up/down sensors on the O_LIFT
Used by: CP5,CP643,GSP5,GP2,GP3,GP551,GP6,IP3,NP132,NP133
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
The out-conveyor mid-stopper engaged,but the engaged limit sensor did not turn ON within the specified
time.
The out-conveyor mid-stopper disengaged,but the disengaged limit sensor did not
turn ON within the specified time.
The out-conveyor mid-stopper engaged and disengaged limit sensors both ON.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
Make sure the out-conveyor mid-stopper engages and disengages smoothly.Make sure the engaged and
disengaged limit sensors have been attached at the correct positions.
Make sure the engaged and disengagedlimit sensors (the I/O input signals listed
below) turn ON and OFF.
Make sure the engaged and disengagedlimit sensors (the I/O input signals listed
below) turn ON and OFF correctly when the out-conveyor mid-stopper is engaged and disengaged.
I/O input signals(CP643):
LX00A: OUT-conveyor mid-stopper engaged(up) limit sensor
LX00B: OUT-conveyor mid-stopper disengaged(down) limit sensor
------------------------------
Code: 15010603
Display: Command Error: OUT
PCB Setting Error:O_LIFT
Chk brd status on out-lif
Used by: CP5,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The [FEED]
command when there is already a board. If there was a board on the conveyor the machine attempted to
第 1093 页