FUJI错误代码查询.pdf - 第2153页
Used by: Cause: The confirmation dialog displays at each time of completion. Remedy: Select [Yes] to finish. Select [No] to continue. ------------------------------ Code: 2305001B Display: The optimized program has not b…
Display: When using [Fix Feeders], there is no such slot available for the tray.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050012
Display: When using [Fix Feeders], there is no such slot available for the feeder.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050013
Display: When using [Fix Feeders], a feeder is too wide to place at an end slot was specified.
Used by:
Cause: In the program's feeder setup, a feeder too wide to place at an end slot was specified.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050015
Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close
to the feeder to the left.
Used by:
Cause: In the program's feeder setup, a feeder wide enough to interfere with the adjacent feeder on the
left side.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23050018
Display: A feeder included in fixed feeder processing is too wide to be loaded on the stage.
Used by:
Cause: A tray included in fixed feeder processing is too wide to be loaded in the pallet.
Remedy: In the part data, check the tray length (PARTS/PACKCLS/PPCTRDX) and the tray width
(PARTS/PACKCLS/PPCTRDY) settings.
------------------------------
Code: 23050019
Display: A tray included in fixed feeder processing is too wide to be loaded side by side in the pallet.
Used by:
Cause: When the tray specified in the program file is placed alongside another tray in the pallet, the
combined tray width exceeds the pallet width.
Remedy: In the program file's feeder setup, check the stage number (PROGRAM/DEVICE+/GUTSTN) and
slot number (PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder
Arrangement] setting for optimization.
------------------------------
Code: 2305001A
Display: Are you finished?
第 2152 页
Used by:
Cause: The confirmation dialog displays at each time of completion.
Remedy: Select [Yes] to finish. Select [No] to continue.
------------------------------
Code: 2305001B
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, or optimization process has completed, but the optimized
program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
When attempting to open the program file, select [No] to abandon the optimized program, and display the
dialog for selecting a new program file to be optimized.
When optimization process has completed, select [No] to exit without saving the optimized program.
------------------------------
Code: 2305001C
Display: No nozzle is registered.
Used by:
Cause: No valid nozzle match could be made between the Nozzle Config. file's NCFTYPE and the Nozzle
Spec. file乫s NSPNAME.
Remedy: There is a problem with either or both files. Normally, the Nozzle Config. and Nozzle Spec. files
in the MCS-X default directory are read automatically. Check that both files contain correct data. When
starting up the optimizer, in cases where prompted to specify a file because the default file cannot be
found, check the file contents and correct if necessary.
------------------------------
Code: 2305001D
Display: Nozzle Configuration File "Fujinzl.cfg" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 2305001E
Display: The contents of Nozzle Configuration File are empty.
Used by:
Cause: The Nozzle Config. file is empty.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2305001F
Display: Contents are not Nozzle Configuration File.
Used by:
Cause: The field "UNIT", "NZLCONF" does not exist.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050020
Display: Cannot read the file.
第 2153 页
Used by:
Cause: An error occurred while reading the Nozzle Config. file.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050021
Display: There are no data for "XP241" in the file.
Used by:
Cause: XP241 Nozzle Config. information (XP241 specified in NZLCONF/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050022
Display: There is no field ["BLOCK","CONFIG+"] for "XP241" in the file.
Used by:
Cause: The field ["BLOCK","CONFIG+"] does not exist in the XP241 Nozzle Config. information (XP241
specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050023
Display: There is no nozzle information for "XP241" in the file.
Used by:
Cause: In the XP241 Nozzle Config. information file (XP241 specified in NZLCONF/HEADER/TYPE), there
are insufficient fields between the ["BLOCK","CONFIG+"] field and the end of the file.
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050024
Display: The nozzle items "NCFNAME" or "NCFTYPE" do not exist in the file.
Used by:
Cause: The Nozzle Name and Nozzle Type cannot be obtained because either or both of the fields,
"NCFNAME" and "NCFTYPE" are missing from underneath the ["BLOCK","CONFIG+"] field in the XP241
Nozzle Config. information file (XP241 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050025
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
configuration items.
Used by:
第 2154 页