FUJI错误代码查询.pdf - 第1220页

Code: 1CFF500C Display: 1CFF500C Used by: Cause: Failed to delete the "nozzle object". Remedy: This error occurs if an "nozzle object" deletion is attempted before the "nozzle object" has be…

100%1 / 5282
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5005
Display: 1CFF5005
Used by:
Cause: Failed to generate the "calibration object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5006
Display: 1CFF5006
Used by:
Cause: Failed to generate the "part object".
Remedy: This error occurs if a re-registration is attempted without deleting the object, or when "part
object" generation is attempted before the "calibration object" has been registered. This is not a common
error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact
Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5008
Display: 1CFF5008
Used by:
Cause: Failed to register direction check data.
Remedy: This error occurs if a function is executed before generating the "parts object". This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5009
Display: 1CFF5009
Used by:
Cause: Failed to delete the "acquire object".
Remedy: This error occurs if an "acquire object" deletion is attempted before the "acquire object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500A
Display: 1CFF500A
Used by:
Cause: Failed to delete the "part object".
Remedy: This error occurs if an "part object" deletion is attempted before the "part object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500B
Display: 1CFF500B
Used by:
Cause: Failed to delete the "calibration object".
Remedy: This error occurs if an "calibration object" deletion is attempted before the "calibration object"
has been registered. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
第 1219 页
Code: 1CFF500C
Display: 1CFF500C
Used by:
Cause: Failed to delete the "nozzle object".
Remedy: This error occurs if an "nozzle object" deletion is attempted before the "nozzle object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500D
Display: 1CFF500D
Used by:
Cause: Failed to delete the "fiducial object".
Remedy: This error occurs if an "fiducial object" deletion is attempted before the "fiducial object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500E
Display: 1CFF500E
Used by:
Cause: Failed to generate the "fiducial object".
Remedy: This error occurs if a re-registration is attempted without deleting the object, or when "part
object" generation is attempted before the "calibration object" has been registered. This is not a common
error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact
Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500F
Display: 1CFF500F
Used by:
Cause: Failed to generate the " nozzle object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5010
Display: 1CFF5010
Used by:
Cause: Failed to generate the "nozzle inspection object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5011
Display: 1CFF5011
Used by:
Cause: Failed to set the nozzle offset.
Remedy: This error occurs if an attempt is made to specify the nozzle offset before the "nozzle object" has
been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5012
Display: 1CFF5012
第 1220 页
Used by:
Cause: Failed to read the nozzle offset value.
Remedy: This error occurs if an attempt is made to read the nozzle offset value before the "nozzle object"
has been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5013
Display: 1CFF5013
Used by:
Cause: Failed to read the nozzle center value.
Remedy: This error occurs if an attempt is made to read the nozzle center value before the "nozzle object"
has been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFFF001
Display: Communication Error with Vision Processor
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: Communication is not possible due to a vision processing error.
Remedy: Turn off the machine.If this error occurs often contact Fuji.
------------------------------
Code: 1CFFF003
Display: Application Error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: Error in the parameters determining the vision processing method.
Remedy: Turn off the machine.If this occurs often contact Fuji.
------------------------------
Code: 1CFFF004
Display: VP Software Version Error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: The vision processing function was not supported in the vision processing software.
Remedy: Use the up-grade version software supporting the necessary functions.
------------------------------
Code: 1CFFF006
Display: Application error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when the specified registered image does not exist.
Remedy: Turn off the machine. Reset-start the machine.If this occurs often contact Fuji.
------------------------------
Code: 1CFFF007
Display: Application error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: The specific data for the registered image is wrong.
Remedy: Turn off the machine. Restart the machine. If this occurs often contact Fuji.
------------------------------
Code: 1CFFF008
Display: Communication Error with Multiplexer.
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when communication with the multiplexer becomes impossible.
Remedy: Turn off the machine and ensure that the cables are connected to the multiplexer.
------------------------------
Code: 1CFFF009
第 1221 页