Code: 1207E?13 Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "Reply Time Out" (QP2) Used by: QP242,QP201,QP202,QP203 Cause: The machine was unable to respond to a request from the PMC within the…
------------------------------
Code: 1207E?0D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Machine Stop(SCU Error)" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command could not be executed because the SCU was stopped due to an error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the SCU error, press the RESET switch, and restart the machine.
------------------------------
Code: 1207E?0E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Specified Axis Exists" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The specified axis does not exist.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify the desired axis using a proper axis number.
------------------------------
Code: 1207E?0F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MTU Not Ready/MTU Locked" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The conditions for tray unit activation where not met. (The tray unit is locked.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to clear the tray lock status.
------------------------------
Code: 1207E?10
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Axis Not at Origin" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The shuttle (TY-axis) is not at the origin position.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to set the shuttle at the origin position.
------------------------------
Code: 1207E?11
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Doed Not Exit" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no board on the conveyor.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Set a board on the conveyor. Make sure that the board arrival check sensor is functioning
normally.
------------------------------
Code: 1207E?12
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Positioning NG" (QP2)
Used by: QP242
Cause: Index-type nozzle positioning error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Rotate the nozzle to the positioning complete position. Make sure that the nozzle positioning
check sensor is functioning normally.
------------------------------
第 817 页
Code: 1207E?13
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reply Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine was unable to respond to a request from the PMC within the specified time.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?14
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Transfer Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A board did not arrive within the specified time, resulting in a board transfer error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that board transport occurs smoothly. Make sure that the board arrival check sensor
is functioning normally.
------------------------------
Code: 1207E?15
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Transport Mode" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command could not be executed because a board transport mode was being executed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?16
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Feeder is Indexing" (QP2)
Feeder is Indexing.(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The machine stopped while a feeder was indexing.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
The machine stopped while a feeder was indexing.(NP2,QP3)
Remedy: Use I/O commands or another method to initialize the indexing feeder.
------------------------------
Code: 1207E?17
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MFU Clamp Error" (QP2)
Used by: QP242
Cause: MFU clamp timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?18
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MFU Unclamp Error" (QP2)
Used by: QP242
Cause: MFU unclamp timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
第 818 页
Code: 1207E?19
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC Device Reqest Logic Err" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There was a logic error in a PMC device request.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?1A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Change Sta Pos'g NG" (QP2)
Used by: QP242
Cause: There is an error in the nozzle change station upper and lower limits.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the nozzle change station. Make sure that the
upper and lower end sensors are functioning normally.
------------------------------
Code: 1207E?1B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Change Sta Pos'g NG" (QP2)
Used by: QP242
Cause: Reject conveyor operation error (positioning timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure the positioning sensor on the reject conveyor is functioning normally.
------------------------------
Code: 1207E?1C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Therml Break Trip;Rjct Conv" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Reject conveyor operation error (thermal relay tripped).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Reset the thermal relay.
------------------------------
Code: 1207E?1D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reject Conveyor Full" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The reject conveyor is full.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the rejected parts from the reject conveyor. Make sure that the reject conveyor full
check sensor is functioning normally.
------------------------------
Code: 1207E?1E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl-Changer and Shutter Err" (QP2)
Used by: QP242
Cause: Nozzle changer/shutter operation error (timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that nothing is interfering with the nozzle change shutter. Make sure that the shutter
open and close limit sensors are functioning normally.
------------------------------