FUJI错误代码查询.pdf - 第243页
Display: File-type error! Used by: NP2,QP3 Cause: The selected file is not a nozzle station specifications file. Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the setting…
Cause: Nozzle settings for this machine are not included in the nozzle settings file. All nozzle settings
have been cleared.
Remedy: Download a compatible nozzle settings file, reboot the machine and load the settings using the
[Update] command.
------------------------------
Code: 11100801
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle station settings file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100802
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle station settings file.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100803
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle station settings file. All nozzle settings have
been cleared.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100804
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle station settings file. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100805
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle station settings for this machine are not included in the nozzle station settings file. All
nozzle settings have been cleared.
Remedy: Download a compatible nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100901
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle station specifications file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the
settings using the [Update] command.
------------------------------
Code: 11100902
第 242 页
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle station specifications file.
Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the
settings using the [Update] command.
------------------------------
Code: 11100903
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle station data items displayed in the parameter section are outside the prescribed range.
All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100904
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle station specifications
file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100905
Display: Nozzle station inconsistency error!
Used by: NP2,QP3
Cause: The nozzle station spec. names displayed in the parameter section are listed in the nozzle station
settings file, but are missing from the nozzle station specifications file.
Remedy: Download compatible nozzle station settings and specification files, reboot the machine and load
the settings using the [Update] command.
------------------------------
Code: 11100906
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: CCIMF file format error in nest specifications file. All nozzle data has been cleared from memory.
Remedy: Download a normal nest specifications file, then start up the machine. Use the nozzle memory
change command to re-register the nozzles.
------------------------------
Code: 11100907
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle station specifications for this machine are not included in the nozzle station specification
file. All nozzle settings have been cleared.
Remedy: Download a compatible nozzle station specification file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100A01
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open camera definition file. Cannot use the camera(s).
Remedy: Download or reinstall an uncorrupted camera definition file and restart the machine.
------------------------------
第 243 页
Code: 11100A02
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the camera definition file is too old. Cannot use the camera(s).
Remedy: Download or reinstall as correct camera definition file and restart the machine.
------------------------------
Code: 11100A03
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the camera definition file is too new. Cannot use the camera(s).
Remedy: Download or reinstall a correct camera definition file and restart the machine.
------------------------------
Code: 11100A04
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the camera definition file.
Remedy: Download or reinstall a correct camera definition file and restart the machine.
------------------------------
Code: 11100A05
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The camera definition data items displayed in the parameter section are outside the prescribed
range. Cannot use the camera(s).
Remedy: Download or reinstall an uncorrupted camera definition file and restart the machine.
------------------------------
Code: 11100A06
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the camera definition file.
Remedy: Download or reinstall a correct camera definition file and restart the machine.
------------------------------
Code: 11100A07
Display: Camera definition file error
Used by: NP2,QP3
Cause: A camera definition file error occurred. Cameras cannot be used at this time.
Remedy: Re-install a normal camera definition file, then start up the machine.
------------------------------
Code: 11100B01
Display: File-open error!
Used by: NP2,QP3
Cause: Nozzle Proper data file could not be opened. Either file does not exist or it is damaged.
Remedy: Download correct nozzle proper data file or reinstall and then reboot machine.
------------------------------
Code: 11100B02
Display: File save error!
Used by: NP2,QP3
Cause: Nozzle Proper data file could not be written to hard disk. Save of nozzel Proper data has failed.
Remedy: Inspect the hard disk.
------------------------------
Code: 11100B03
Display: File creation error!
第 244 页