FUJI错误代码查询.pdf - 第650页

Display: Auto Tape Supply Err Used by: GL541 Cause: The tape was not fed from the automatic tape supply unit. Remedy: Make sure that the tape has not been cut and that the automatic tape supply unit has not been removed.…

100%1 / 5282
Remedy:
------------------------------
Code: 120630B5
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630B6
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630B7
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630B8
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630B9
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630BA
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630BB
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120630BC
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12064001
第 649 页
Display: Auto Tape Supply Err
Used by: GL541
Cause: The tape was not fed from the automatic tape supply unit.
Remedy: Make sure that the tape has not been cut and that the automatic tape supply unit has not been
removed.
------------------------------
Code: 12066000
Display: SS-axis Interlock
Used by:
Cause: (1) There is a possibility that the position where the step slide axis is currently located might
interfere with a pallet loading or unloading. (2)The combination of the step slide pin and the step slide
axis being unclamped prohibits inching. (3) The process is prohibited because the step slide pin is
engaged.
Remedy: (1), (3) When automatic operation is restarted following the clearing of an emergency stop
during index motion, there is a possibility that the step slide might interfere with a pallet loading or
unloading.
It is because of this that the SS-axis must be moved to a safe position. If at this time, the step slide is
clamped to the pallet, the SS-axis and the entire pallet are moved together. Be careful that the pallet
position is not out of place because, if it is, operation cannot be restarted. Generally though, unclamp the
pallet and move just the SS-axis.
1. If the pallet is clamped, set Y04F: SS_PLT_UNCLAMP1 and Y061: SS_PLT_UNCLAMP2 to ON and
unclamp the pallet.
2. Set Y063: SS_PIN_OFF to ON and disengage the SS-axis pin.
3. Check that the X06B: SS_PIN_OFF setting and the X066: SS_PLT_UNCLAMP setting is ON.
------------------------------
Code: 12066001
Display:
Used by: QP132
Cause: The machine stopped due to a pallet initiation error which occurred during the first half of
processing.
Remedy: Execute PLT CHANGE and try initiation again. When changing pallets, remove only the pallet
located in the front. It is possible to re-execute initiation without removing the pallet located in the rear
(the return conveyor side).
------------------------------
Code: 12066002
Display:
Used by: QP132
Cause: The machine stopped due to a pallet initiation error which occurred during the second half of
processing.
Remedy: Perform PLT CHANGE and try initiation again. When changing pallets, remove only the pallet
located in the front. It is possible to re-execute initiation without removing the pallet located in the rear
(the return conveyor side).
------------------------------
Code: 12066003
Display: Vision Time out
Used by: QP132
Cause: Vision processing was not completed within the set time. The time out duration depends on the
content of vision processing.
Remedy: If the error LED of the vision processing board VP4100/4800 is on, the board may be defective.
If the same error occurs when operation is resumed, restart the machine. If the placing head is holding
parts, first dump the parts and then restart the machine.
第 650 页
------------------------------
Code: 120661??
Display: Bad nozzle detected:PM??-?
Used by: QP132
Cause: The number of vision processing errors has exceeded the specified figure, and the nozzle is
therefore judged to be defective.
The question marks in the code represent the module number and the nozzle number in that order. The
first two question marks in the display represent the module number, and the question mark after the
hyphen represents the nozzle number.
Remedy: Check the status of the nozzles.
------------------------------
Code: 12066800
Display: DATA LOGIC ERROR [12066800]
Used by: QP132
Cause: There is no data table for setting the fiducial mark that has been read. Or The Pallet ID issued
during advanced pick-up is incorrect. On the QP132, the board information is saved in the table when the
board is loaded, and Data is written to each pallet ID at the Approach Station. As a result, when a board
exists in the pallet loader after being set using the I/O operation, the board information will be deleted if
the reset-start operation is carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066801
Display: DATA LOGIC ERROR [12066801]
Used by: QP132
Cause: There is no program to be executed at the mark read station.
Remedy: Transmit the necessary program.
------------------------------
Code: 12066802
Display: DATA LOGIC ERROR [12066802]
Used by: QP132
Cause: When the pallet size corresponding to the stored ID was read, data different than the pallet size
being used in production was detected.
Remedy: Check the pallet size in the machine. Has the wrong size pallet been inserted? If a pallet change
has been carried out the pallet initialization operation may not in fact be necessary, nevertheless this
initialization operation should always be carried out when a new pallet is used. Also note that the
possibility exists that the pallet initialization operation is not properly completedevery time. In such a case
execute the [PLT CHANGE] command, unload the pallets, and then execute the [INITI TION] command.
------------------------------
Code: 12066803
Display: DATA LOGIC ERROR [12066803]
Used by: QP132
Cause: The pitch was not continuous when the five individual IDs attached to the pallet were read at the
approach station.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
第 651 页