FUJI错误代码查询.pdf - 第1164页
Code: 180100F3 Display: ERRCODE: 0x180100F3 Used by: Handy terminal (QP132) Cause: Error in received command data. (For example, the Device Status data exceeded the prescribed range.) Remedy: The wrong software version i…
Cause: An STU tray supply time out condition occurred.
Remedy: Check for jammed tray in the STU tray feeder, or for a parts out condition.
------------------------------
Code: 16010012
Display: Stick exchange error
Used by: QP3
Cause: An error occurred while exchanging a feeder stick.
Remedy: After correcting the problem, press the feeder's reset button to clear the error.
------------------------------
Code: 18010001
Display: ERRCODE: 0x18010001
Used by: Handy terminal (QP132)
Cause: Format of transmitted command is incorrect.
Remedy: Restart the machine and the handy terminal.
------------------------------
Code: 18010002
Display: ERRCODE: 0x18010002
Used by: Handy terminal (QP132)
Cause: FIDL was not found.
Remedy: Check to see if the correct feeder was designated. Or, set the correct feeder on the PFU, execute
association processing, then repeat the "verify" request.
------------------------------
Code: 18010003
Display: ERRCODE: 0x18010003
Used by: Handy terminal (QP132)
Cause: Busy status occurred during machine operation.
Remedy: Reexecute later.
------------------------------
Code: 180100F0
Display: ERRCODE: 0x180100F0
Used by: Handy terminal (QP132)
Cause: An undefined command was received. A command not included in the command list (at
specifications) was received.
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
software version.
------------------------------
Code: 180100F1
Display: ERRCODE: 0x180100F1
Used by: Handy terminal (QP132)
Cause: The received command had an improper packet length. The received packet length differed from
that defined by the program.
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
version.
------------------------------
Code: 180100F2
Display: ERRCODE: 0x180100F2
Used by: Handy terminal (QP132)
Cause: The command does not match the transmission/reception identifier. (For example, the version
command was "MVRM", but the identifier was "R".)
Remedy: Restart the machine and the handy terminal.
------------------------------
第 1163 页
Code: 180100F3
Display: ERRCODE: 0x180100F3
Used by: Handy terminal (QP132)
Cause: Error in received command data. (For example, the Device Status data exceeded the prescribed
range.)
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
version.
------------------------------
Code: 180100F4
Display: ERRCODE: 0x180100F4
Used by: Handy terminal (QP132)
Cause: Machine version information is incorrect. The MVRP, MVRM machine software version number is
other than "0".
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
version.
------------------------------
Code: 180100F5
Display: ERRCODE: 0x180100F5
Used by: Handy terminal (QP132)
Cause: Communication time out. A reply was not received within the specified time period.
Remedy: Verify that the machine power is ON and that machine connections are correct, then press the
[ENTER] key.
------------------------------
Code: 180100F6
Display: ERRCODE: 0x180100F6
Used by: Handy terminal (QP132)
Cause: Port control error. An error report was received from a device during COM port control (writing,
reading, etc.).
Remedy: Restart the machine and the Handy terminal.
------------------------------
Code: 180100F7
Display: ERRCODE: 0x180100F7
Used by: Handy terminal (QP132)
Cause: An inappropriate (invalid) reply was received. (For example, "VSRP" was transmitted, but a
"VCEP" reply was received.)
Remedy: Restart the machine and the Handy terminal.
------------------------------
Code: 180100F8
Display: ERRCODE: 0x180100F8
Used by: Handy terminal (QP132)
Cause: Incorrect Machine type. The MVRP and MVRM machine software version is other than "0x00 to
0x02".
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
version.
------------------------------
Code: 18010101
Display: HT err:****
Used by: QP132
Cause: The verify request (including splicing check) subject FIDL (feeder information) does not exist in
the machine's PFU data.
"****" is the command name.
第 1164 页
Remedy: Check to see if the wrong feeder was designated as the verify request subject. Or, set the subject
feeder on the PFU, establish an association, then repeat the verify request.
------------------------------
Code: 18010102
Display: HT err:****
Used by: QP132
Cause: The HT report initiated by a verify request (including splicing check) contains the wrong FIDL.
"****" is the command name.
Remedy: Check to see if the wrong feeder was designated as the verify request subject. Or, set the subject
feeder on the PFU, establish an association, then repeat the verify request.
------------------------------
Code: 18010103
Display: HT err:****
Used by: QP132
Cause: The HT report initiated by a verify request (including splicing check) contains the wrong device
comment.
"****" is the command name.
Remedy: Check whether there is an error in the stage, slot or subslot of the device subject to verification.
------------------------------
Code: 18010104
Display: HT err:****
Used by: QP132
Cause: The HT report initiated by a verify request (including splicing check) contains the wrong stage,
slot, or sub-slot.
"****" is the command name.
Remedy: Check whether there is an error in the device comment of the device subject to verification.
------------------------------
Code: 18010105
Display: HT err:**** No applicable FIDL
Used by: QP132
Cause: The HT report initiated by a verify request (including splicing check) indicates an FIDL change,
but the new FIDL (feeder information) does not exist in the machine's PFU data.
"****" is the command name.
Remedy: Check to see if the wrong feeder was specified. Or, set the subject feeder on the PFU, establish
an association, then repeat the verify request.
------------------------------
Code: 18010106
Display: None
Used by: QP132
Cause: A verify request (including splicing check) was issued before the zero setting operation was
completed. When a zero setting is carried out, the PFU power is turned ON, a continuous association is
established, and feeder information is obtained.
Remedy: Execute the verify request (including splicing check) after the zero setting operation is
completed.
------------------------------
Code: 18010107
Display: None
Used by: QP132
Cause: A verify request (including splicing check) was issued without a PFU installed.
Remedy: Execute the verify request (including splicing check) after the PFU is installed.
------------------------------
第 1165 页