Make sure that the forward end and retract end sensors (X03C and X03D) turn on when the cylinder moves. ------------------------------ Code: 12054044 Display: Air Cylinder Cycle Alarm Cleaner Wiper Used by: Cause: Wiper …

100%1 / 5282
sensor is broken.
Remedy: Check the operation of the clamper at the I/O board, and check the sensors.
------------------------------
Code: 1205403E
Display:
Used by:
Cause: The stroke frame unclamper cannot operate. Alternately, the stroke frame unclamper
confirmation sensor is broken.
Remedy: Check the operation of the unclamper at the I/O board, and check the sensors.
------------------------------
Code: 1205403F
Display: The tape cutter error.
Used by: CP-732E,CP-742ME,CP-742E,CP-752E
Cause: It works tape cutter, being connected with the multitude time sending by the feeder
but it doesn't work normally.
The sensor of the end of the tape cutter forward movement doesn't ON during automatic operation.
Remedy: During multitude time sending execution, confirm that the tape cutter cylinder works.
When this error occurs though the cylinder is working, adjust a sensor of the end of the forward
movement and a sensor of the end of the backward movement.
This error occurs when the automatic operation starts. In case of being, adjust a sensor of the end of the
forward movement.
------------------------------
Code: 12054040
Display:
Used by: GP551,GP6
Cause: Mask reception was not completed within the specified time.
Remedy: Check that the mask reception cylinder and sensors work correctly, and check that no objects
are interfering with the movement of the cylinder. If there are, remove the objects. Otherwise, adjust or
replace the cylinder.
------------------------------
Code: 12054041
Display: 周期异常 印刷压力响应
Used by: GSP5,GP2,GP3,GP551,GP6,GPX,NXTP
Cause: 不能够施加所设定的印刷压力下限值以上的印刷压力。 最大压和最小压都没有达到设定的印刷压力。 (GPX)
Remedy: 请确认印刷压力测定用放大器中是否正确地设定了印刷压力。可认为是气源进口压低于印刷压力下限值的设
定。请将印刷压力的设定值变更为合适的值。 存在刮刀没有到达钢板的可能性。请确认刮刀的安装是否正常。(GPX)
<img src="$LKEY_ERRIMG_MC$/12054041.PNG">
------------------------------
Code: 12054042
Display: Pre-RQ rotation Error
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Pre-RQ rotation could not be performed within the cycle time (Station 13).
Remedy: Check that the axis is not overloaded. Remove any objects that interfere with axis
movement.Check the cylinder's advance and retract sensors.
------------------------------
Code: 12054043
Display: "Tape feed cylinder alarm" (CP6)
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The tape feed cylinder did not advance or retreat within the specified time.
Remedy: Perform an I/O check OUT operation to turn off cylinder stopper Y026, then make sure that the
cylinder moves forward and retracts when the cam handle is turned or when C-axis inching is performed.
第 550 页
Make sure that the forward end and retract end sensors (X03C and X03D) turn on when the cylinder
moves.
------------------------------
Code: 12054044
Display: Air Cylinder Cycle Alarm Cleaner Wiper
Used by:
Cause: Wiper operation is incorrect.
Remedy: The wiper's forward and retract sensors may be faulty. Adjust or replace the sensors.
------------------------------
Code: 12054045
Display: "Cycle alarm: squeegee separation pressure response"
Used by: GSP5,GP6
Cause: The pressure level has been reduced from printing pressure to squeegee separation pressure, but
the lower limit signal (X072:SQG PRES LO) has not turned on.
Remedy: Make sure the squeegee separation pressure has been properly set for the pressure
measurement amp (#2). Make sure that the pressure applied during printing is not lower than that
applied forsqueegee separation. Set a lower squeegee pressure value for squeegee separation than is used
when printing.
------------------------------
Code: 12054046
Display: "Tape cutter cylinder alarm"
Used by: CP652C
Cause: The tape cutter cylinder did not move up or down within the specified time.
Remedy: Perform an I/O check OUT operation to turn off cylinder stopper Y036, then make sure that the
cylinder moves up and down when the cam handle is turned or when cam axis inching is performed.When
the cylinder moves, make sure that the upper and lower limit sensors (X034 and X035) turn on If the
upper and lower limit sensors (X034 and X035) do not turn on even when the cylinder moves up and
down normally, adjust the sensors and such as needed.
------------------------------
Code: 12054047
Display: Cycle Alarm Cylinder Towel Feed UP/DOWN
Used by: GSP5,GP551,GP6,NXTP
Cause: The cleaner towel feed operation was not completed within the specified amount of time.
Remedy: Make sure that additional force is not being exerted on the towel feed operation.
------------------------------
Code: 12054048
Display: Cycle Alarm Cylinder Cleaner Shaft
Used by: GP6
Cause: There was no sensor input by the cleaner shaft advance/retract limit sensor within the specified
amount of time.
Remedy: Confirm that the cleaner shaft operation is working correctly.
------------------------------
Code: 1205404D
Display: Tool changer error
Used by: QP3OF
Cause: There is a possibility of interference between the tool changer and the holder.
Remedy: Raise the Z-axis to a position where it will not interfere with the tool changer and holder. Also,
open the [Position] ? [Toll Changer Position] screen from the [Main] screen to lower the tool changer.
------------------------------
Code: 1205404E
Display: Tool changer error
第 551 页
Used by: QP3OF
Cause: A timeout error occurred while raising/lowering the tool changer.
Remedy: Check that the tool changer is not interfering with any other part of the machine.
------------------------------
Code: 12054050
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054051
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054052
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054053
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054054
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054055
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054056
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054057
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished